  1. Effects of different torque levels on the implant-abutment interface in a conical internal connection

    Sergio Alexandre GEHRKE, Jamil Awad SHIBLI, Jaime Sardá ARAMBURÚ JUNIOR e mais 3Brazilian Oral Research2016citado por 1 artigo

    Abstract The fit of the implant-abutment interface was assessed by the metallographic technique and by scanning electron microscopy (SEM), using solid abutment types at different torque levels. Forty Morse taper connections and forty solid abutments were used at different torque levels (repeated after 10 minutes) in…

  2. Connecting accuracy of interchanged prosthetic abutments to different dental implants using scanning electron microscopy

    Piero Rocha Zanardi, Bruno Costa, Roberto Chaib Stegun e mais 3Brazilian Dental Journal2012citado por 2 artigos

    The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments…

  3. Corrosion behavior of zirconia in acidulated phosphate fluoride

    Anie Thomas, Sathyanarayanan Sridhar, Shant Aghyarian e mais 4Journal of Applied Oral Science2016

    ABSTRACT Objective The corrosion behavior of zirconia in acidulated phosphate fluoride (APF) representing acidic environments and fluoride treatments was studied. Material and Methods Zirconia rods were immersed in 1.23% and 0.123% APF solutions and maintained at 37°C for determined periods of time. Surfaces of all…

  4. Effects of different angles of abutment screw channel on removal torque value of ball torx screws

    Fatemeh Bakhtiari, Ramin Negahdari, Amirreza Babaloo e mais 2Brazilian Journal of Oral Sciences2025

    Aim This study investigates the impact of various tightening protocols on torque requirements in screw-retained crowns, focusing on the Angulated Screw Channel (ASC) system. The ASC alters the screw channel angle in the crown while aligning the abutment with the implant, potentially enhancing function and aesthetics…

  5. Influence of crown and hybrid abutment ceramic materials on the stress distribution of implant-supported prosthesis

    João Paulo Mendes TRIBST, Amanda Maria de Oliveira DAL PIVA, Alexandre Luiz Souto BORGES e mais 1Revista de Odontologia da UNESP2018citado por 3 artigos

    Abstract Introduction A new dental implant-abutment design is available with the possibility of improving aesthetic with no compromise of mechanical strength, using perforated CAD/CAM ceramic blocks. Objective This study evaluated the influence of crown and hybrid abutment ceramic materials combination on the stress…

  6. Influence of Abutment Collar Height and Implant Length on Stress Distribution in Single Crowns

    Dimorvan Bordin, Altair Antoninha Del Bel Cury e Fernanda FaotBrazilian Dental Journal2019

    Abstract This in silico study evaluated the influence of the abutment collar height and implants length on the biomechanical behavior of morse taper single dental implants with different crown-to-implant ratio. Six virtual models were constructed (S11, M11, L11, S13, M13 and L13) by combining short (S: 2.5 mm), medium…

  7. The assessment of periimplant soft tissue condition with morse taper abutment connection: a rapid review

    Puspa Puspita Lasminingrum, Aldilla Miranda, Dyah Nindita Carolina e mais 1Brazilian Journal of Oral Sciences2022

    Aim This study aims to evaluate the clinical assessment results of periimplant soft tissue with morse taper (internal abutment connection). Methods The study was conducted using a rapid review by searching the articles from PubMed NCBI and Cochrane by using keywords. All articles were selected by the year…

  8. Load-bearing capacity of screw-retained CAD/CAM-produced titanium implant frameworks (I-Bridge®2) before and after cyclic mechanical loading

    Marc Philipp Dittmer, Moritz Nensa, Meike Stiesch e mais 1Journal of Applied Oral Science2013

    Implant-supported screw-retained fixed dental prostheses (FDPs) produced by CAD/ CAM have been introduced in recent years for the rehabilitation of partial or total endentulous jaws. However, there is a lack of data about the long-term mechanical characteristics. OBJECTIVE: The aim of this study was to investigate the…

  9. Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique

    Karina Bergamo Cardoso, Edmara Tatiely Pedroso Bergamo, Vitor De Moraes Cruz e mais 3Journal of Applied Oral Science2020

    Abstract An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. Objective: This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (μCT). Methodology…

  10. One Abutment at One Time Concept for Platform-Switched Morse Implants: Systematic Review and Meta-Analysis

    Joanes Silva Santos, Thiago de Santana Santos, Paulo Ricardo Saquete Martins Filho e mais 3Brazilian Dental Journal2018

    Abstract The aim of this systematic review and meta-analysis was to compare the peri-implant vertical bone loss of immediate loading of implant crowns using the one abutment at one time (AOT) protocol and implants with abutment removal (AR). This systematic review with meta-analysis was reported according to the…

  11. Bacterial microleakage at the implant-abutment interface in Morse taper implants

    João Paulo da Silva-Neto, Marina de Freitas Fratari Majadas, Marcel Santana Prudente e mais 3Brazilian Journal of Oral Sciences2014citado por 1 artigo

    AIM: To evaluate the microleakage at the implant-abutment (I-A) interface of Morse tapered implants inoculated with different volumes of bacterial suspension.METHODS: Morse tapered I-A sets were selected and divided in two groups depending on the type of abutment: passing screw (PS) and solid (S), and then subdivided…

  12. Morse taper internal connection implants: would abutment reseating influence retention?

    Stenio Cardoso Rabelo, Sheyla Viana Omonte, Sarita Pires Vieira e mais 2Brazilian Journal of Oral Sciences2015

    Abstract Aim: To investigate whether the removal and reseating of the abutment influences the retention of Morse taper implant system. Methods: Two Morse taper implant systems were selected: Bicon Dental ImplantTM system (Bicon, LLC, Boston, MA, USA) and Kopp Implant(r) system (Kopp(r), Curitiba, PR, Brazil). In both…

  13. Internal and Marginal Fit and Fracture Strength of Narrow Diameter Dental Implant-Abutment Assembly

    George Hebert Ruschel, Ataís Bacchi, Izabela Cristina Maurício Moris e mais 3Brazilian Dental Journal2020

    Abstract The aim of this study was to assess the internal and vertical marginal fit of metallic copings to abutments and the fracture strength of different narrow diameter dental implant/abutments, either submitted to thermomechanical cycling or not. Sixty-four implant/abutments (n=16) were divided into 4 groups…

  14. Influence of abutment and connection type on implant-abutment connection rigidity: an in vitro study

    Teresa Almeida Mendes, Luís Miguel Vilhena, Jaime Portugal e mais 3Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial2022

    Abstract Objectives: To evaluate the effects of the abutment material and the connection type on the implant-abutment connection rigidity. Methods: The study evaluated eighteen implants with three different types of connections: external-hexagon, tri-channel, and conical connection. Half of the implants were connected…

  15. Removal torque of zirconia abutment screws under dry and wet conditions

    Frederico Nigro, Claudio L. Sendyk, Carlos Eduardo Francischone Jr. e mais 1Brazilian Dental Journal2010

    The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision…

  16. Micro-leakage at the implant-abutment interface with different tightening torques in vitro

    João Paulo da Silva-Neto, Marcel Santana Prudente, Thiago de Almeida Prado Naves Carneiro e mais 3Journal of Applied Oral Science2012citado por 1 artigo

    OBJECTIVES: This study evaluated the microleakage at the implant/abutment interface of external hexagon (eH) implants and abutments with different amounts of bacteria and tightening torques. MATERIAL AND METHODS: A bacterial suspension was prepared to inoculate the implants. The first phase of this study used nine EH…

  17. External Hexagon Deformation in Implants Subjected to Internal Torque

    Denildo Magalhães, Marina Melo Naves, Helder Henrique Machado Menezes e mais 3Brazilian Dental Journal2015

    Failures may occur in the connections of dental implants, especially in external hexagon (EH). Due to the deformations in this portion of implants, this study aimed to evaluate the levels of deformation of EH connections subjected to internal toque. Two types of implants were used: N group and S group. Torques of 0…

  18. Tightening techniques for the retaining screws of universal abutment

    Alexandre Wittcinski REGALIN, Rodrigo ALESSANDRETTI, Leonardo FEDERIZZI e mais 3Revista de Odontologia da UNESP2016

    Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control – 32 Ncm torque; H20 – holding 32 Ncm torque for 20 s; R – 32 Ncm…

  19. Does the implant-abutment interface interfere on marginal bone loss? A systematic review and meta-analysis

    Enéias Carpejani ROSA, Tatiana Miranda DELIBERADOR, Tuanny Carvalho de Lima do NASCIMENTO e mais 6Brazilian Oral Research2019

    Abstract The objective of this systematic review was to compare the conical internal connection (IC) with the external hexagonal connection (EH) on the occurrence of marginal bone loss (ΔMBL). Different databases were used to carry out the selection of the elected studies. The studies were judged according to the risk…

  20. Comparative analysis of microgaps in angled and straight components: a laboratory study

    Yuri Lins LOBO, Giovanna Nascimento MENDES, Lucas Alves da Mota SANTANA e mais 4Revista de Odontologia da UNESP2024

    Abstract Introduction The dental implant rehabilitation protocol is a well-established treatment option for edentulous patients with a high success rate. However, there are factors that can lead to difficulty in continuation and even complete loss of rehabilitation. Microgaps are spaces found between the implant and…