Brazilian Journal of Oral Sciences2015

Morse taper internal connection implants: would abutment reseating influence retention?

Stenio Cardoso Rabelo, Sheyla Viana Omonte, Sarita Pires Vieira, Wellington Correa Jansen e Paulo Isaias Seraidarian

em inglês

cita 20 obras, 2 no acervo

resumo

Abstract Aim: To investigate whether the removal and reseating of the abutment influences the retention of Morse taper implant system. Methods: Two Morse taper implant systems were selected: Bicon Dental ImplantTM system (Bicon, LLC, Boston, MA, USA) and Kopp Implant(r) system (Kopp(r), Curitiba, PR, Brazil). In both systems, the abutment is connected to the implant with a locking taper. To seat the abutment, the same vertical force was applied in both systems. It was measured the compressive force necessary to engage effectively the locking taper connection and the tensile force to displace it. Results: The compressive force was determined by four activations in each abutment-implant set, and the sum of these forces was 21 N and 17 N in the BiconTM and Kopp(r) systems, respectively. Next, a tensile test was performed, revealing that the BiconTM system presented a 208 N resistance, whereas it was 194 N in the Kopp(r) system. Other three rounds of compression and tensile loads were applied, removing and reseating the abutment. We obtained the following tensile values: 367 N, 500 N and 756 N in the BiconTM System and 336 N, 360 N and 420 N in the Kopp(r) system. Conclusions: When the sets were subjected to repeated rounds of compressive and tensile forces, displacing and reseating the abutment, the tensile value increased.

como citar · ABNT NBR 6023

RABELO, Stenio Cardoso et al. Morse taper internal connection implants: would abutment reseating influence retention? Brazilian Journal of Oral Sciences, 2015. DOI: 10.1590/1677-3225V14N3A07.

Referências

20 obras citadas · 2 no acervo

  1. 1MS Pita, RB Anchieta, VA Barão e mais 3. Prosthetic platforms in implant dentistry. J Craniofac Surg, 2011quem mais cita →
  2. 2G Sannino e A Barlattani. Mechanical evaluation of an implant-abutment self-locking taper connection finite element analysis and experimental tests. Int J Oral Maxillofac Implants, 2013quem mais cita →
  3. 3F Mangano, A Macchi, A Caprioglio e mais 3. Survival and complication rates of fixed restorations supported by locking-taper implants a prospective study with 1 to 10 years of follow-up. J Prosthodont, 2014quem mais cita →
  4. 4CM Schmitt, G Nogueira-Filho, HC Tenenbaum e mais 3. Performance of conical abutment (Morse Taper) connection implants a systematic review. J Biomed Mater Res A, 2014quem mais cita →
  5. 5Y Yamanishi, S Yamaguchi, S Imazato e mais 2. Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement three-dimensional finite element analysis. Dent Mater, 2012quem mais cita →
  6. 6JG Wittneben, D Buser, GE Salvi e mais 3. Complication and failure rates with implant-supported fixed dental prostheses and single crowns a 10-year retrospective study. Clin Implant Dent Relat Res, 2014quem mais cita →
  7. 7MC Junqueira, RF Ribeiro, ACL Faria e mais 2. Screw loosening of different UCLA-type abutments after mechanical cycling. Braz J Oral Sci, 2013no acervo →
  8. 8RE Jung, A Zembic, BE Pjetursson e mais 2. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res, 2012quem mais cita →
  9. 9RJ Chapman e W Grippo. The locking taper attachment for implant abutments use and reliability. Implant Dent, 1996quem mais cita →
  10. 10NJ Shepherd. Affordable implant prosthetics using a screwless implantsystem. J Am Dent Assoc, 1998quem mais cita →
  11. 11K Keating. Connecting abutments to dental implants "an engineer's perspective". Irish. Dent, 2001quem mais cita →
  12. 12B Assenza, D Tripodi, A Scarano e mais 3. Bacterial leakage in implants with different implant-abutment connections an in vitro study. J Periodontol, 2012quem mais cita →
  13. 13JP Silva-Neto, MFF Majadas, MS Prudente e mais 3. Bacterial microleakage at the implant-abutment interface in Morse taper implants. Braz J Oral Sci, 2014no acervo →
  14. 14C do Nascimento, PK Miani, V Pedrazzi e mais 3. Leakage of saliva through the implant-abutment interface in vitro evaluation of three different implant connections under unloaded and loaded conditions. Int J Oral Maxillofac Implants, 2012quem mais cita →
  15. 15GH Nentwig. Ankylos implant system concept and clinical application. JOral Implantol, 2004quem mais cita →
  16. 16PC Feitosa, AP de Lima, LR Silva-Concílio e mais 2. Stability of external and internal implant connections after a fatigue test. Eur J Dent, 2013quem mais cita →
  17. 17RA Urdaneta, M Marincola, M Weed e mais 1. A screwless andcementless technique for the restoration of single-tooth implants a retrospective cohort study. J Prosthodont, 2008quem mais cita →
  18. 18MR Norton. An in vitro evaluation of the strength of an internal conicalinterface compared to a butt joint interface in implant design. Clin Oral Implants Res, 1997quem mais cita →
  19. 19JC Zielak, M Rorbacker, R Gomes e mais 3. In vitro evaluation of the removal force of abutments in frictional dental implants. J Oral Implantol, 2011quem mais cita →
  20. 20JM Gere e SP Timoshenko. Mechanics of materials. 1997quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações