acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “dental implant-abutment design”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Influence of metal bar lever-arm on screws detorque for dental prosthesis implant supported

    Wilson MATSUMOTO, Ana Paula MACEDO, Rossana Pereira de ALMEIDA e mais 2Revista de Odontologia da UNESP2020

    Abstract Introduction The cantilever length of implant-supported fixed prosthesis metal structure has been considered an important factor to transfer occlusion forces to the dental implant. Objective This study evaluated the influence of different extensions of cantilevers of Branemark protocol implant prosthesis when…

  2. Influence of crown and hybrid abutment ceramic materials on the stress distribution of implant-supported prosthesis

    João Paulo Mendes TRIBST, Amanda Maria de Oliveira DAL PIVA, Alexandre Luiz Souto BORGES e mais 1Revista de Odontologia da UNESP2018citado por 3 artigos

    Abstract Introduction A new dental implant-abutment design is available with the possibility of improving aesthetic with no compromise of mechanical strength, using perforated CAD/CAM ceramic blocks. Objective This study evaluated the influence of crown and hybrid abutment ceramic materials combination on the stress…

  3. Implant-based factor as possible risk for peri-implantitis

    Daniela Leal ZANDIM-BARCELOS, Gabriel Garcia de CARVALHO, Vitor Marques SAPATA e mais 3Brazilian Oral Research2019

    Abstract Peri-implantitis is currently a topic of major interest in implantology. Considered one of the main reasons of late implant failure, there is an emerged concern whether implant characteristics could trigger inflammatory lesion and loss of supporting bone. The purpose of this narrative review is to provide an…

  4. Influence of abutment and connection type on implant-abutment connection rigidity: an in vitro study

    Teresa Almeida Mendes, Luís Miguel Vilhena, Jaime Portugal e mais 3Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial2022

    Abstract Objectives: To evaluate the effects of the abutment material and the connection type on the implant-abutment connection rigidity. Methods: The study evaluated eighteen implants with three different types of connections: external-hexagon, tri-channel, and conical connection. Half of the implants were connected…

  5. Tightening techniques for the retaining screws of universal abutment

    Alexandre Wittcinski REGALIN, Rodrigo ALESSANDRETTI, Leonardo FEDERIZZI e mais 3Revista de Odontologia da UNESP2016

    Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control – 32 Ncm torque; H20 – holding 32 Ncm torque for 20 s; R – 32 Ncm…

  6. Does the implant-abutment interface interfere on marginal bone loss? A systematic review and meta-analysis

    Enéias Carpejani ROSA, Tatiana Miranda DELIBERADOR, Tuanny Carvalho de Lima do NASCIMENTO e mais 6Brazilian Oral Research2019

    Abstract The objective of this systematic review was to compare the conical internal connection (IC) with the external hexagonal connection (EH) on the occurrence of marginal bone loss (ΔMBL). Different databases were used to carry out the selection of the elected studies. The studies were judged according to the risk…

  7. The assessment of periimplant soft tissue condition with morse taper abutment connection: a rapid review

    Puspa Puspita Lasminingrum, Aldilla Miranda, Dyah Nindita Carolina e mais 1Brazilian Journal of Oral Sciences2022

    Aim This study aims to evaluate the clinical assessment results of periimplant soft tissue with morse taper (internal abutment connection). Methods The study was conducted using a rapid review by searching the articles from PubMed NCBI and Cochrane by using keywords. All articles were selected by the year…

  8. Failure of prosthetic screws on 971 implants

    Carolina Schäffer Morsch, Caroline Freitas Rafael, Juan Felipe Montero Dumes e mais 3Brazilian Journal of Oral Sciences2015

    Abstract Aim: To evaluate the presence of failures in prosthetic screws and whether these failures are related to the type of prosthesis, abutment angulation and presence or not of intermediate. Methods: Two-hundred and sixty-seven patients were evaluated at the Federal University of Santa Catarina, totaling 971…

  9. Morse taper internal connection implants: would abutment reseating influence retention?

    Stenio Cardoso Rabelo, Sheyla Viana Omonte, Sarita Pires Vieira e mais 2Brazilian Journal of Oral Sciences2015

    Abstract Aim: To investigate whether the removal and reseating of the abutment influences the retention of Morse taper implant system. Methods: Two Morse taper implant systems were selected: Bicon Dental ImplantTM system (Bicon, LLC, Boston, MA, USA) and Kopp Implant(r) system (Kopp(r), Curitiba, PR, Brazil). In both…

  10. Connecting accuracy of interchanged prosthetic abutments to different dental implants using scanning electron microscopy

    Piero Rocha Zanardi, Bruno Costa, Roberto Chaib Stegun e mais 3Brazilian Dental Journal2012citado por 2 artigos

    The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments…

  11. Strain analysis of different diameter Morse taper implants under overloading compressive conditions

    Carolina Guimarães CASTRO, Karla ZANCOPÉ, Crisnicaw VERÍSSIMO e mais 2Brazilian Oral Research2015citado por 1 artigo

    The aim of this study was to evaluate the amount of deformation from compression caused by different diameters of Morse taper implants and the residual deformation after load removal. Thirty Morse taper implants lacking external threads were divided into 3 groups (n = 10) according to their diameter as follows: 3.5…

  12. Comparative analysis of microgaps in angled and straight components: a laboratory study

    Yuri Lins LOBO, Giovanna Nascimento MENDES, Lucas Alves da Mota SANTANA e mais 4Revista de Odontologia da UNESP2024

    Abstract Introduction The dental implant rehabilitation protocol is a well-established treatment option for edentulous patients with a high success rate. However, there are factors that can lead to difficulty in continuation and even complete loss of rehabilitation. Microgaps are spaces found between the implant and…

  13. Compressive Resistance of Abutments with Different Diameters and Transmucosal Heights in Morse-Taper Implants

    Ricardo Lillo, Carlos Parra, Ramón Fuentes e mais 3Brazilian Dental Journal2015

    The aim of this study was to evaluate the compressive resistance under oblique loads of abutments with two different diameters and transmucosal heights used for cement-retained implant-supported prostheses in Morse-taper implants. Forty Morse-taper implants were divided into four groups with different abutment sizes…

  14. Influence of implant-abutment angulations and crown material on stress distribution on central incisor: a 3D FEA

    Mohamed I. El-Anwar, Khairy E. AL-Azrag, Mohamed H. Ghazy e mais 1Brazilian Journal of Oral Sciences2015

    Abstract Aim: To investigate the effect of implant-abutment angulation and crown material on stress distribution of central incisors. Finite element method was used to simulate the clinical situation of a maxillary right central incisor restored by two different implant-abutment angulations, 15° and 25°, using two…

  15. Mechanical testing of thin-walled zirconia abutments

    Luigi CANULLO, Paulo G. COELHO e Estevam A. BONFANTEJournal of Applied Oral Science2013

    Although the use of zirconia abutments for implant-supported restorations has gained momentum with the increasing demand for esthetics, little informed design rationale has been developed to characterize their fatigue behavior under different clinical scenarios. However, to prevent the zirconia from fracturing, the…

  16. Prosthetic abutment influences bone biomechanical behavior of immediately loaded implants

    Germana de Villa CAMARGOS, Bruno Salles SOTTO-MAIOR, Wander José da SILVA e mais 2Brazilian Oral Research2016citado por 2 artigos

    Abstract This study aimed to evaluate the influence of the type of prosthetic abutment associated to different implant connection on bone biomechanical behavior of immediately and delayed loaded implants. Computed tomography-based finite element models comprising a mandible with a single molar implant were created…

  17. Influence of cantilever position and implant connection in a zirconia custom implant-supported fixed partial prosthesis: in silico analysis

    Juliana Maria Coutinho BASTOS, Dimorvan BORDIN, Andréa Araújo de VASCONCELLOS e mais 1Revista de Odontologia da UNESP2018

    Abstract Introduction A better tension distribution on implants and abutments in implant-supported fixed partial prosthesis is essential in the rehabilitation of posterior mandible area. Objective: To evaluate the influence of cantilever position and implant connection in a zircônia custom implant-supported fixed…

  18. Immediate full-arch rehabilitation of atrophic maxilla using extra-long implants with bicortical anchorage in the canine pillars: a 16-month case report

    Farid Jamil Silva de Arruda, Andrew Sotirios Melenikiotis, Paola Rebelatto Alcântara e mais 3Brazilian Journal of Oral Sciences2025

    Rehabilitation of atrophic maxilla can be challenging, being used bone augmentation and modified implant designs. Despite many studies on more complex techniques, such as zygomatic implants. There are practically no case reports in literature using extra-long implants with bicortical anchorage in canine pillars for…

  19. Measurement of the interface of external connection implants with metal or zirconia abutments under scanning electron microscopy

    Blanca Nieves-Rodriguez, Jair Rodríguez-Ivich, Nana Kwame Ampomah e mais 1RGO - Revista Gaúcha de Odontologia2025

    ABSTRACT Objective Microgap at the implant–abutment interface is a critical factor that may influence both survival- and success rates of dental implants. Several studies have found that the shape of the abutment and implant, the kind of connection between the implant and abutment (external, internal, conical, and…

  20. Three-dimensional finite element analysis of three internal tapered implant-abutment designs

    Geninho THOMÉ, Rafael Calixto SALATTI, Larissa Carvalho TROJAN e mais 2RGO - Revista Gaúcha de Odontologia2023

    ABSTRACT Objective: The aim of this study was to compare the stress distribution in internal tapered connection implants with different adaptation geometries submitted to oblique load simulation using the Finite Element Analysis (FEA) method. Methods: Three different internal tapered implant-abutment assemblies were…