Journal of Applied Oral Science2012
Micro-leakage at the implant-abutment interface with different tightening torques in vitro
João Paulo da Silva-Neto, Marcel Santana Prudente, Thiago de Almeida Prado Naves Carneiro, Mauro Antônio de Arruda Nóbilo, Mario Paulo Amante Penatti e Flávio Domingues das Neves
em inglês
citado por 1 artigocita 30 obras, 2 no acervo
resumo
OBJECTIVES: This study evaluated the microleakage at the implant/abutment interface of external hexagon (eH) implants and abutments with different amounts of bacteria and tightening torques. MATERIAL AND METHODS: A bacterial suspension was prepared to inoculate the implants. The first phase of this study used nine EH implants and abutments that were divided into three groups with different amounts of bacterial suspension (n=3): V0.5: 0.5 µL; V1.0: 1.0 µL e V1.5: 1.5 µL, and tightened to the manufacturer's recommended torque. The second phase of this experiment used 27 assemblies that were similar to those used in the first phase. These samples were inoculated with 0.5 µL of bacterial suspension and divided into three groups (n=9). T10: 10 Ncm; T20: 20 Ncm and T32: 32 Ncm. The samples were evaluated according to the turbidity of the broth every 24 hours for 14 days, and the bacteria viability was tested after that period. The statistical evaluation was conducted by Kruskal-Wallis testing (p<.05). RESULTS: During the first phase, groups V1.0 and V1.5 was presented with bacterial contamination in all samples after 24 h. During the second phase, two samples from group T10 and one from T20 presented positive results for bacterial contamination. Different amounts of bacterial solution led to overflow and contamination during the first 24 h of the experiment. The tightening torques did not statistically affect the microleakage in the assemblies. However, the group that was tightened to 32 Ncm torque did not show any bacterial contamination. CONCLUSION: After 14 days of experimentation, the bacteria were proven to remain viable inside the implant internal cavity.
como citar · ABNT NBR 6023
SILVA-NETO, João Paulo da et al. Micro-leakage at the implant-abutment interface with different tightening torques in vitro. Journal of Applied Oral Science, 2012. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572012000500015. Acesso em: 29 nov. 2026.
Referências
30 obras citadas · 2 no acervo
- 1T Albrektsson, G Zarb, P Worthington e mais 1. The long-term efficiency of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants, 1986quem mais cita →
- 2T Albrektsson. Standard specification for unalloyed titanium for surgical implant applications. Annual book of ASTM standards. Medical devices and services, 1997quem mais cita →
- 3RE Barbosa, C Nascimento, JP Issa e mais 3. Bacterial culture and DNA Checkerboard for the detection of internal contamination in dental implants. J Prosthodont, 2009quem mais cita →
- 4CE Besimo, JS Guindy, D Lewetag e mais 1. Prevention of bacterial leakage into and from prefabricated screw-retained crowns on implants in vitro. Int J Oral Maxillofac Implants, 1999quem mais cita →
- 5N Broggini, LM McManus, JS Hermann e mais 3. Peri-implant inflammation defined by the implant-abutment interface. J Dent Res, 2006quem mais cita →
- 6N Broggini, LM McManus, JS Hermann e mais 3. Persistent acute inflammation at the implant-abutment interface. J Dent Res, 2003quem mais cita →
- 7D Byrne, F Houston, R Cleary e mais 1. The fit of cast and pre-machined implant abutments. J Prosthet Dentquem mais cita →
- 8PG Coelho, P Sudack, M Suzuki e mais 3. In vitro evaluation of the implant-abutment connection sealing capability of different implant systems. J Oral Rehabil, 2008quem mais cita →
- 9S Dibart, M Warbington, MF Su e mais 1. In vitro evaluation of the implant-abutment bacterial seal: the locking taper system. Int J Oral Maxillofac Implants, 2005quem mais cita →
- 10AR Duarte, PH Rossetti, LM Rossetti e mais 2. In vitro sealing ability of two materials at five different implant-abutment surfaces. J Periodontol, 2006quem mais cita →
- 11CJ Goodacre, G Bernal, K Rungcharassaeng e mais 1. Clinical complications with implants and implant prostheses. J Prosthet Dent, 2003quem mais cita →
- 12JS Guindy, CE Besimo, R Besimo e mais 2. Bacterial leakage into and from prefabricated screw-retained implant-borne crowns in vitro. J Oral Rehabil, 1998quem mais cita →
- 13M Gross, I Abramovich e EI Weiss. Microleakage at the abutment-implant interface of osseointegrated implants: a comparative study. Int J Oral Maxillofac Implants, 1999quem mais cita →
- 14S Harder, B Dimaczek, Y Açil e mais 3. Molecular leakage at implant-abutment connection - in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration. Clin Oral Investig, 2010quem mais cita →
- 15JS Hermann, D Buser, RK Schenk e mais 1. Crestal bone changes around titanium implants: A histometric evaluation of unloaded non-submerged and submerged implants in the canine mandible. J Periodontol, 2000quem mais cita →
- 16VK Jansen, G Conrads e EJ Richter. Microbial leakage and marginal fit of the implant-abutment interface. Int J Oral Maxillofac Implants, 1997quem mais cita →
- 17RJ Lazzara e SS Porter. Platform switching: a new concept in implant dentistry for controlling post-restorative crestal bone levels. Int J Periodontics Restorative Dent, 2006quem mais cita →
- 18SP Nair, S Meghji, M Wilson e mais 3. Bacterially induced bone destruction: mechanisms and misconceptions. Infect Immun, 1996quem mais cita →
- 19C Nascimento, RE Barbosa, JP Issa e mais 3. Bacterial leakage along the implant-abutment interface of pre-machined or cast components. Int J Oral Maxillofac Surg, 2008quem mais cita →
- 20C Nascimento, RE Barbosa, JP Issa e mais 3. Use of checkerboard DNA-DNA hybridization to evaluate the internal contamination of dental implants and comparison of bacterial leakage with cast or pre-machined abutments. Clin Oral Implants Res, 2009quem mais cita →
Quem cita esta obra
1 artigo do acervo
quem fala desta obra
6 pessoas- Thiago de Almeida Prado Naves Carneiroautocitação1 artigo · 2014
- Marina de Freitas Fratari Majadas1 artigo · 2014
- Flávio Domingues das Nevesautocitação1 artigo · 2014
- Mario Paulo Amante Penattiautocitação1 artigo · 2014
- Marcel Santana Prudenteautocitação1 artigo · 2014
- João Paulo da Silva-Netoautocitação1 artigo · 2014