acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Dental abutments”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Connecting accuracy of interchanged prosthetic abutments to different dental implants using scanning electron microscopy

    Piero Rocha Zanardi, Bruno Costa, Roberto Chaib Stegun e mais 3Brazilian Dental Journal2012citado por 2 artigos

    The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments…

  2. Corrosion behavior of zirconia in acidulated phosphate fluoride

    Anie Thomas, Sathyanarayanan Sridhar, Shant Aghyarian e mais 4Journal of Applied Oral Science2016

    ABSTRACT Objective The corrosion behavior of zirconia in acidulated phosphate fluoride (APF) representing acidic environments and fluoride treatments was studied. Material and Methods Zirconia rods were immersed in 1.23% and 0.123% APF solutions and maintained at 37°C for determined periods of time. Surfaces of all…

  3. Effects of different angles of abutment screw channel on removal torque value of ball torx screws

    Fatemeh Bakhtiari, Ramin Negahdari, Amirreza Babaloo e mais 2Brazilian Journal of Oral Sciences2025

    Aim This study investigates the impact of various tightening protocols on torque requirements in screw-retained crowns, focusing on the Angulated Screw Channel (ASC) system. The ASC alters the screw channel angle in the crown while aligning the abutment with the implant, potentially enhancing function and aesthetics…

  4. Influence of Abutment Collar Height and Implant Length on Stress Distribution in Single Crowns

    Dimorvan Bordin, Altair Antoninha Del Bel Cury e Fernanda FaotBrazilian Dental Journal2019

    Abstract This in silico study evaluated the influence of the abutment collar height and implants length on the biomechanical behavior of morse taper single dental implants with different crown-to-implant ratio. Six virtual models were constructed (S11, M11, L11, S13, M13 and L13) by combining short (S: 2.5 mm), medium…

  5. The assessment of periimplant soft tissue condition with morse taper abutment connection: a rapid review

    Puspa Puspita Lasminingrum, Aldilla Miranda, Dyah Nindita Carolina e mais 1Brazilian Journal of Oral Sciences2022

    Aim This study aims to evaluate the clinical assessment results of periimplant soft tissue with morse taper (internal abutment connection). Methods The study was conducted using a rapid review by searching the articles from PubMed NCBI and Cochrane by using keywords. All articles were selected by the year…

  6. Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique

    Karina Bergamo Cardoso, Edmara Tatiely Pedroso Bergamo, Vitor De Moraes Cruz e mais 3Journal of Applied Oral Science2020

    Abstract An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. Objective: This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (μCT). Methodology…

  7. Bacterial microleakage at the implant-abutment interface in Morse taper implants

    João Paulo da Silva-Neto, Marina de Freitas Fratari Majadas, Marcel Santana Prudente e mais 3Brazilian Journal of Oral Sciences2014citado por 1 artigo

    AIM: To evaluate the microleakage at the implant-abutment (I-A) interface of Morse tapered implants inoculated with different volumes of bacterial suspension.METHODS: Morse tapered I-A sets were selected and divided in two groups depending on the type of abutment: passing screw (PS) and solid (S), and then subdivided…

  8. Internal and Marginal Fit and Fracture Strength of Narrow Diameter Dental Implant-Abutment Assembly

    George Hebert Ruschel, Ataís Bacchi, Izabela Cristina Maurício Moris e mais 3Brazilian Dental Journal2020

    Abstract The aim of this study was to assess the internal and vertical marginal fit of metallic copings to abutments and the fracture strength of different narrow diameter dental implant/abutments, either submitted to thermomechanical cycling or not. Sixty-four implant/abutments (n=16) were divided into 4 groups…

  9. Micro-leakage at the implant-abutment interface with different tightening torques in vitro

    João Paulo da Silva-Neto, Marcel Santana Prudente, Thiago de Almeida Prado Naves Carneiro e mais 3Journal of Applied Oral Science2012citado por 1 artigo

    OBJECTIVES: This study evaluated the microleakage at the implant/abutment interface of external hexagon (eH) implants and abutments with different amounts of bacteria and tightening torques. MATERIAL AND METHODS: A bacterial suspension was prepared to inoculate the implants. The first phase of this study used nine EH…

  10. Mechanical performance and bacterial leakage in low-cost external hexagon dental implants: implications for post-market surveillance

    Diana Ribeiro do Espírito Santo Jacomo, Mônica Diuana Calasans-Maia, Mike dos Reis Bueno e mais 4Brazilian Journal of Oral Sciences2026

    Aim This study aimed to evaluate low-cost external-hexagon dental implant systems acquired in Brazil between 2014 and 2016, focusing on compliance with international standards, mechanical behavior, microbial leakage, and integrity of the implant–abutment interface. Methods Three external hexagon implant systems were…

  11. Effect of cast rectifiers on the marginal fit of UCLA abutments

    Ana Paula Gumieiro Jaime, Diego Klee de Vasconcellos, Alfredo Mikail Melo Mesquita e mais 2Journal of Applied Oral Science2007

    OBJECTIVES: This study assessed the effect of cast rectifiers on the marginal misfit of cast UCLA abutments compared to premachined UCLA abutments. The influence of casting and porcelain baking on the marginal misfit of these components was also investigated. METHODS: Two groups were analyzed: test group - 10 cast…

  12. Fracture of abutment screw supporting a cemented implant-retained prosthesis with external hexagon connection: a case report with sem evaluation

    Mariana Diniz Bisi Santos, Arthur Braga Pfeifer, Marcos Rogério Pupo Silva e mais 2Journal of Applied Oral Science2007citado por 3 artigos

    One of the causes of implant failures in cemented implant-retained prostheses is the fracture of abutment screw or UCLA abutment. This article reports a case of simultaneous fracture of two UCLA abutments screws occurring in an implant-supported prosthesis placed in the mandibular molar region. The fractured…

  13. Effect of Using Nano and Micro Airborne Abrasive Particles on Bond Strength of Implant Abutment to Prosthesis

    Mansour Rismanchian, Amin Davoudi e Elham ShadmehrBrazilian Dental Journal2015

    Connecting prostheses to the implant abutments has become a concern and achieving a satisfactory retention has been focused in cement-retention prostheses recently. Sandblasting is a method to make a roughened surface for providing more retention. The aim of this study was to compare effects of nano and micro airborne…

  14. Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses

    Vinicius Pavesi Fardin, Gerson Bonfante, Paulo G. Coelho e mais 6Journal of Applied Oral Science2022

    Abstract Glass ceramics’ fractures in zirconia fixed dental prosthesis (FDP) remains a clinical challenge since it has higher fracture rates than the gold standard, metal ceramic FDP. Nanoindentation has been shown a reliable tool to determine residual stress of ceramic systems, which can ultimately correlate to…

  15. Mechanical testing of thin-walled zirconia abutments

    Luigi CANULLO, Paulo G. COELHO e Estevam A. BONFANTEJournal of Applied Oral Science2013

    Although the use of zirconia abutments for implant-supported restorations has gained momentum with the increasing demand for esthetics, little informed design rationale has been developed to characterize their fatigue behavior under different clinical scenarios. However, to prevent the zirconia from fracturing, the…

  16. Stress analysis of a fixed implant-supported denture by the finite element method (FEM) when varying the number of teeth used as abutments

    Marcos Daniel Septímio Lanza, Paulo Isaías Seraidarian, Wellington Correa Jansen e mais 1Journal of Applied Oral Science2011citado por 1 artigo

    OBJECTIVES: In some clinical situations, dentists come across partially edentulous patients, and it might be necessary to connect teeth to implants. The aim of this study was to evaluate a metal-ceramic fixed tooth/implant-supported denture with a straight segment, located in the posterior region of the maxilla, when…

  17. Influence of Resin Cements on the Tension Force of Cast Frameworks Made by the Technique of Framework Cemented on Prepared Abutments

    Ana Paula Perroni, Érica Alves Gomes, Amália Machado Bielemann e mais 4Brazilian Dental Journal2015

    This study evaluated the tension force of cast frameworks made by the technique of framework cemented on prepared abutments using two different resin cements. Forty multi-unit abutment analogs were individually fixed with chemically cured acrylic resin inside PVC cylinders using a parallelometer. Brass cylindrical…

  18. Assessment of the tensile strength of hexagonal abutments using different cementing agents

    Carlos Wahl, Fabiana Mantovani Gomes França, Rui Barbosa Brito Jr e mais 2Brazilian Oral Research2008

    The aim of this study was to assess the uniaxial tensile strength after thermal cycling in replicas of CeraOne®abutments (abutment and coping sets), using four types of cements (n = 10). A zinc phosphate cement (Fosfato de Zinco®/ SSW), a resin-modified glass ionomer cement (RelyX®luting / 3M-ESPE), a zinc…

  19. Compressive Resistance of Abutments with Different Diameters and Transmucosal Heights in Morse-Taper Implants

    Ricardo Lillo, Carlos Parra, Ramón Fuentes e mais 3Brazilian Dental Journal2015

    The aim of this study was to evaluate the compressive resistance under oblique loads of abutments with two different diameters and transmucosal heights used for cement-retained implant-supported prostheses in Morse-taper implants. Forty Morse-taper implants were divided into four groups with different abutment sizes…

  20. Measurement of the interface of external connection implants with metal or zirconia abutments under scanning electron microscopy

    Blanca Nieves-Rodriguez, Jair Rodríguez-Ivich, Nana Kwame Ampomah e mais 1RGO - Revista Gaúcha de Odontologia2025

    ABSTRACT Objective Microgap at the implant–abutment interface is a critical factor that may influence both survival- and success rates of dental implants. Several studies have found that the shape of the abutment and implant, the kind of connection between the implant and abutment (external, internal, conical, and…