acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Pedicle Screws”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Comparison between posterior lumbar fusion with pedicle screws and posterior lumbar interbody fusion with pedicle screws in adult spondylolisthesis

    Fernando Luiz Rolemberg Dantas, Mirto Nelso Prandini e Mauro A.T. FerreiraArquivos de Neuro-Psiquiatria2007

    The purpose of this study was to compare patients with lumbar spondylolisthesis submitted to two different surgical approaches, and evaluate the results and outcomes in both groups. In a two-year period, 60 adult patients with lumbar spondylolisthesis, both isthmic and degenerative, were submitted to surgery at the…

  2. FREE-HAND PLACEMENT OF C7 PEDICLE SCREWS: A CADAVERIC STUDY

    Emiliano Vialle, Luis Herrera, Luiz Roberto Vialle e mais 1Coluna/Columna2015

    Objective : To evaluate the accuracy of free-hand pedicle screws placement at the seventh cervical vertebra. Methods : The authors have exposed the cervicothoracic junction of 9 adult cadavers (7 male and 2 female) preserved in formalin from the Faculty of Medicine of the Universidad Andina Néstor Cáceres Velásquez…

  3. Pedicle Screws and Facet Violation - The importance of the Angle between the Facet and the Screw

    Rodrigo Amaral, Luiz Pimenta, Angelo Guarçoni Netto e mais 2Revista Brasileira de Ortopedia2020

    Abstract Objective To verify whether, regardless of the screw placement technique, there is a safe distance or angle in relation to the facets that can prevent violation of the facet joint when the screws are placed. Methods Retrospective, single, comparative, non-randomized center. We evaluated by axial computed…

  4. MINIMALLY INVASIVE LUMBAR ARTHRODESIS AND PERCUTANEOUS PEDICLE SCREWS: A SYSTEMATIC REVIEW

    VINICIUS DE MELDAU BENITES, FABIO VEIGA DE CASTRO SPARAPANI, EDUARDO AUGUSTO IUNES e mais 4Coluna/Columna2020

    ABSTRACT A systematic review of the literature was performed in order to organize, evaluate, and select evidences available about the safety and efficacy of minimally invasive percutaneous arthrodesis with percutaneous pedicle screws in the treatment of patients with degenerative disc disease (and other spinal…

  5. Free-hand placement of high thoracic pedicle screws with the aid of fluoroscopy: evaluation of positioning by CT scans in a four-year consecutive series

    Bruno Perocco Braga, Josaphat Vilela de Morais e Marcelo Duarte VilelaArquivos de Neuro-Psiquiatria2010

    OBJECTIVE: To evaluate the feasibility, safety and accuracy of pedicle screw placement in the upper thoracic spine using the free-hand technique with the aid of fluoroscopy; to analyze the methods used to verify correct screw positioning intra and postoperatively. METHOD: All patients with instability of the…

  6. TREATMENT OF THORACOLUMBAR FRACTURES BY CLOSED REDUCTION VIA A PERCUTANEOUS SOLID PEDICLE SCREW

    Changzhi Cheng, Guiqian Li, Yuanguo Luo e mais 1Acta Ortopédica Brasileira2023

    ABSTRACT Objectives: Investigate the effect of closed reduction and per- cutaneous pedicle screw fixation in treating thoracolumbar fractures. Methods: This retrospective study analyzed 12 cases of single-segment thoracolumbar spine fractures without spinal cord and nerve injury at our department from March 2016 to…

  7. INFLUENCE OF DIAMETER AND GEOMETRY IN THE TAPPING OF THE PILOT HOLE IN PEDICLE SCREWS

    Helton Luiz Aparecido Defino, Raffaello de Freitas Miranda, Romulo Pedroza Pinheiro e mais 1Coluna/Columna2019

    ABSTRACT Objective: To evaluate the insertion torque and the pulling force of each screw with different diameters and tap. Methods: Polyurethane blocks with a pilot hole of 2.7 mm were used in the study. An experimental group with 5 blocks was formed, the insertion torque was evaluated with a torque meter, and the…

  8. EVIDENCE LEVEL OF THE PLACEMENT OF SCREWS OUTSIDE PEDICLE IN THORACIC AND LUMBAR SPINE

    Gabriel Aldama Bustos, Alfredo Javier Moheno Gallardo e Eulalio Elizalde MartínezColuna/Columna2018

    ABSTRACT International recommendations in spine surgery require reproducible, safe and effective procedures. The placement of pedicle screws is technically demanding and relies on different methods of support, which result a high rate of complications related to suboptimal screw placement, with reports ranging from…

  9. CLINICAL APPLICATION OF A DRILL GUIDE TEMPLATE FOR PEDICLE SCREW PLACEMENT IN SEVERE SCOLIOSIS

    Xin Li, Yaoshen Zhang, Qiang Zhang e mais 2Acta Ortopédica Brasileira2017

    ABSTRACT Objective: To evaluate the accuracy and the effect of drill guide template for pedicle screw placement in severe scoliosis. Method: Eight patients with rigid scoliosis were enrolled, five males and three females, ranging from nine to 23 years old. A three-dimensional CT scan of the spine was performed and…

  10. DIRECT PEDICLE SCREW INSERTION PULLOUT STRENGTH

    RÔMULO PEDROZA PINHEIRO, ARIANE ZAMARIOLI, THIBAULT CHANDANSON e mais 3Acta Ortopédica Brasileira2021

    ABSTRACT Objective: Study the in vitro pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw), a screw pedicle designed to be inserted using a direct insertion technique. Methods: DSG Screws of 5.5 mm and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF…

  11. Reduction in radiation (fluoroscopy) while maintaining safe placement of pedicle screws during lumbar spine fusion

    Christopher D. Chaput, Keri George, Amer F. Samdani e mais 3Coluna/Columna2013

    OBJECTIVE: The purpose of this study is to report the results using PediGuard (electrical conductivity device) to reduce radiation exposure while drilling the pilot hole for pedicle screw placement. METHOD: Eighteen patients diagnosed with a degenerative lumbar spine, that required a posterior spinal fusion. Average…

  12. LEVEL OF EVIDENCE IN THE PLACEMENT OF TRANSPEDICULAR SCREWS IN SUBAXIAL CERVICAL SPINE

    Cristóbal Herrera Palacios, Armando Fabio Ramos Guerrero, Gustavo Casas Martínez e mais 2Coluna/Columna2016

    ABSTRACT The high-energy trauma mainly involves vertebral lesions and 6% occur in the cervical region. This poses a challenge to spine surgeons in surgical decision-making, both in terms of approach as the instrumentation. International recommendations establish that the procedures performed are reproducible, safe…

  13. COMPARISON OF MONO AND POLY-AXIAL PEDICLE SCREW FIXATION IN THORACOLUMBAR A3/A4 FRACTURES

    EMILIANO NEVES VIALLE, BARBARA MIROSKI DE OLIVEIRA PINTO, JOANA BRETAS CABRAL RONDOM GUASQUE e mais 2Coluna/Columna2025

    ABSTRACT Objective: This study aims to compare the use of mono-axial and poly-axial screws in AOSpine type A3 and A4 thoracolumbar fractures. Methods: Prospective case-control study involving patients treated surgically with short fixation using mono-axial or poly-axial screws. The type of treatment was chosen…

  14. MORPHOMETRY OF THE POSITIONING OF CORTICAL TRAJECTORY PEDICLE SCREWS IN BRAZILIANS

    FERNANDO MAGALHÃES GOSENDE, ROGÉRIO LÚCIO CHAVES DE RESENDE, CARLOS BAUER NAMEM LOPES JUNIOR e mais 4Coluna/Columna2020

    ABSTRACT Objective Morphometric study of the positioning of the cortical trajectory pedicle screw in the lumbar spine of Brazilian patients of different sexes and ages, through the use of computed tomography images, in order to obtain more reliable data about cortical screw insertion and the variations observed…

  15. INTRA- AND INTEROBSERVER ANALYSIS OF PEDICLE SCREW PLACEMENT IN SCOLIOSIS CORRECTION

    CAÍQUE JAUHAR DE CASTRO, LUIS EDUARDO CARELLI TEIXEIRA DA SILVA, LUIZ EDUARDO ALMEIDA e mais 4Coluna/Columna2020

    ABSTRACT Objective To establish the statistical interobserver and intraobserver concordance of thoracic pedicle screw placement in scoliosis surgery, with a 4-week interval between the two analyses. Methods Of 55 patients that evaluated the intra- and interobserver concordances of the screw positions (according to the…

  16. PEDICLE MORPHOLOGY IN SCOLIOSIS: CLASSIFICATION AGREEMENT FOR PRE-OPERATIVE EVALUATION

    LUIZ EDUARDO PEREIRA COSTA ASSIS DE ALMEIDA, LUIS EDUARDO CARELLI TEIXEIRA DA SILVA, CAIQUE JAUHAR DE CASTRO e mais 3Coluna/Columna2020

    ABSTRACT Objectives Although Watanabe morphological classification is well known, there is no consensus of its use among spine surgeons. We propose an analysis of the Watanabe classification by three observers, one senior and two recently graduated orthopedic spine surgeons, and its applicability in pre-operative…

  17. Analysis of the Limitations of Robotic Systems in Spine Surgery

    Helton Luiz Aparecido Defino, Vinicius Marques Carneiro, Matheus Pippa Defino e mais 4Coluna/Columna2026

    ABSTRACT Objective: To analyze the limitations and complications of using a robotic system in spinal surgeries during the learning curve. Methods: To evaluate the results of the application of 415 pedicle screws in 67 patients undergoing spinal surgery in which the robotic system was used. Recording time, fluoroscopy…

  18. SUBAXIAL CERVICAL PEDICLE SCREWS WITHOUT NAVIGATION: IS IT SAFE AND FEASIBLE?

    Gabriel Farias Alves, Alderico Girão Campos de Barros, Igor Ebert Cechin e mais 1Coluna/Columna2025

    ABSTRACT Objective: The application of pedicle screws in the subaxial cervical spine is a highly complex technique, but with significant biomechanical advantages. Despite the potential complications involved, its use has increased. This study aims to evaluate the clinical and radiological outcomes, as well as the…

  19. RADICULAR SYMPTOMS ASSOCIATED WITH EXTRAPEDICULAR SCREW PLACEMENT

    Jorge Alberto Pérez Terrazas, Daniel Sebastián Rivas Toledano, Arturo Rivera Galindo e mais 4Coluna/Columna2024

    ABSTRACT Objective: Transpedicular fixation has rapidly evolved over the last 100 years. A common complication is screw misplacement which can lead to neurological deficits, vascular damage, or organ perforation. We intend to assess the correlation between screw misplacement and radicular symptoms through the…

  20. LUMBAR ARTHRODESIS IN LATERAL SINGLE POSITION: CONCEPTS, RATIONAL AND CLINICAL-FUNCTIONAL RESULTS OF 100 CONSECUTIVE CASES

    Cristiano Magalhães Menezes, Gabriel Carvalho Lacerda, Marlus Sérgio Borges Salomão Junior e mais 3Coluna/Columna2023

    ABSTRACT Objective: Arthrodesis techniques such as anterior lumbar interbody fusion (ALIF) and lateral lumbar interbody fusion (LLIF) aim to reestablish physiological lordosis and minimize tissue damage to the paravertebral musculature. Supplementation with percutaneous pedicle screws is indicated in most cases…