Coluna/Columna2013
Reduction in radiation (fluoroscopy) while maintaining safe placement of pedicle screws during lumbar spine fusion
Christopher D. Chaput, Keri George, Amer F. Samdani, John I. Williams, John Gaughan e Randal R. Betz
em inglês
resumo
OBJECTIVE: The purpose of this study is to report the results using PediGuard (electrical conductivity device) to reduce radiation exposure while drilling the pilot hole for pedicle screw placement. METHOD: Eighteen patients diagnosed with a degenerative lumbar spine, that required a posterior spinal fusion. Average age of the patients were 55 ± 12 years. Patients received postoperative CT scans of all screws. Scans were reviewed by an independent reviewer grading 'in' < 2 mm of breach , or 'out' > 2 mm of breach. In a randomized fashion, the surgeon created pilot holes with either his standard technique or by using the PediGuard. Fluoroscopy was used for each drilling as necessary. Once the pilot hole was created, the surgeon inserted titanium screws into the pedicle pilot holes. A total of 78 screws (39 standard probe and 39 PediGuard ) were analyzed. RESULTS: 78 screws (39 standard probe and 39 PediGuard were analyzed. No significant difference in breach rate > 2mm by either method (p=1.000), with one screw out in each group. Fluoroscopy shots averaged 5.2 (range, 0 to 15), average decrease of 2.3 (30%) per screw in the PediGuard group vs. 7.5 (range, 2 to 17) in the standard group (p< .001). CONCLUSION: This trial to assess pedicle probe location within the pedicle and vertebral body showed the number of fluoroscopy shots were reduced by 30%, compared to a standard probe while maintaining a 97.5% screw placement accuracy.
como citar · ABNT NBR 6023
CHAPUT, Christopher D. et al. Reduction in radiation (fluoroscopy) while maintaining safe placement of pedicle screws during lumbar spine fusion. Coluna/Columna, 2013. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512013000200009. Acesso em: 29 nov. 2026.
Referências
32 obras citadas
- 1L Hackenberg, T Link e U Liljenqvist. Axial and tangential fixation strength of pedicle screws versus hooks in the thoracic spine in relation to bone mineral density. Spine (Phila Pa 1976), 2002quem mais cita →
- 2SI Suk, CK Lee, WJ Kim e mais 2. Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine (Phila Pa 1976), 1995quem mais cita →
- 3U Liljenqvist, U Lepsien, L Hackenberg e mais 2. Comparative analysis of pedicle screw and hook instrumentation in posterior correction and fusion of idiopathic thoracic scoliosis. Eur Spine J, 2002quem mais cita →
- 4SI Suk, CK Lee, HJ Min e mais 2. Comparison of Cotrel-Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis. Int Orthop, 1994quem mais cita →
- 5DC Burton, MA Asher e SM Lai. Scoliosis correction maintenance in skeletally immature patients with idiopathic scoliosis: Is anterior fusion really necessary?. Spine (Phila Pa 1976), 2000quem mais cita →
- 6TR Kuklo, LG Lenke, O'Brien MF e mais 3. Accuracy and efficacy of thoracic pedicle screws in curves more than 90 degrees. Spine (Phila Pa 1976), 2005quem mais cita →
- 7YJ Kim, LG Lenke e KH Bridwell. Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis: a matched cohort analysis. Scoliosis Research Society Annual Meeting, 2003quem mais cita →
- 8MA Yahiro. Comprehensive literature review: Pedicle screw fixation devices. Spine (Phila Pa 1976), 1994quem mais cita →
- 9PJ Belmont Jr, WR Klemme, A Dhawan e mais 1. In vivo accuracy of thoracic pedicle screws. Spine (Phila Pa 1976), 2001quem mais cita →
- 10PJ Belmont Jr, WR Klemme, M Robinson e mais 1. Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities. Spine (Phila Pa 1976), 2002quem mais cita →
- 11UR Liljenqvist, HF Halm e TM Link. Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine (Phila Pa 1976), 1997quem mais cita →
- 12SI Suk, WJ Kim, SM Lee e mais 2. Thoracic pedicle screw fixation in spinal deformities: are they really safe?. Spine (Phila Pa 1976), 2001quem mais cita →
- 13P Papin, V Arlet, D Marchesi e mais 2. Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J, 1999quem mais cita →
- 14S Yalçin e O Güven. Reversible anterior cord syndrome due to penetration of the spinal canal by pedicular screws. Paraplegia, 1995quem mais cita →
- 15DJ Donovan, DW Polly Jr e SL Ondra. The removal of a transdural pedicle screw placed for thoracolumbar spine fracture. Spine (Phila Pa 1976), 1996quem mais cita →
- 16MD Jendrisak. Spontaneous abdominal aortic rupture from erosion by a lumbar spine fixation device: a case report. Surgery, 1986quem mais cita →
- 17HA Yuan, SR Garfin, CA Dickman e mais 1. A Historical Cohort Study of Pedicle Screw Fixation in Thoracic, Lumbar, and Sacral Spinal Fusions. Spine (Phila Pa 1976), 1994quem mais cita →
- 18T Laine, T Lund, M Ylikoski e mais 2. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J, 2000quem mais cita →
- 19K Perisinakis, N Theocharopoulos, J Damilakis e mais 2. Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion. Spine (Phila Pa 1976), 2004quem mais cita →
- 20M Ul Haque, HL Shufflebarger, M O'Brien e mais 1. Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: is fluoroscopy safe?. Spine (Phila Pa 1976), 2006quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda