Acta Ortopédica Brasileira2021
DIRECT PEDICLE SCREW INSERTION PULLOUT STRENGTH
RÔMULO PEDROZA PINHEIRO, ARIANE ZAMARIOLI, THIBAULT CHANDANSON, KERI GEORGE, ANTONIO CARLOS SHIMANO e HELTON LUIZ APARECIDO DEFINO
em inglês
resumo
ABSTRACT Objective: Study the in vitro pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw), a screw pedicle designed to be inserted using a direct insertion technique. Methods: DSG Screws of 5.5 mm and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF (0,16 g/cm3). According to the experimental group, screws were inserted without pilot hole, with pilot without tapping, undertapping and line-to-line tapping. Screw pullout tests were performed using a universal test machine after screw insertion into polyurethane blocks. Results: Screws inserted directly into the polyurethane blocks without pilot hole and tapping showed a statistically higher pullout strength. Insertion of the screw without tapping or with undertapping increases the pullout screw strength compared to line-to-line tapping. Conclusion: DSG Screw showed the highest pullout strength after its insertion without pilot hole and tapping. Level of Evidence V, Expert Opinion.
como citar · ABNT NBR 6023
PINHEIRO, RÔMULO PEDROZA et al. DIRECT PEDICLE SCREW INSERTION PULLOUT STRENGTH. Acta Ortopédica Brasileira, 2021. DOI: 10.1590/1413-785220212904241648.
Referências
20 obras citadas · 2 no acervo
- 1C Bolger e C Wigfield. Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures. J Neurosurg, 2000quem mais cita →
- 2C Bolger, C Carozzo, T Roger e mais 4. A preliminary study of reliability of impedance measurement to detect iatrogenic initial pedicle perforation (in the porcine model). Eur Spine J, 2006quem mais cita →
- 3LH Chen, CL Tai, PL Lai e mais 3. Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: influences of radial hole and pilot hole tapping. Clin Biomech (Bristol, Avon), 2009quem mais cita →
- 4C Bolger, MO Kelleher, L McEvoy e mais 3. Electrical conductivity measurement: a new technique to detect iatrogenic initial pedicle perforation. Eur Spine J, 2007quem mais cita →
- 5SH Chen, R Mo Lin, HH Chen e mais 1. Biomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support. BMC Musculoskelet Disord, 2007quem mais cita →
- 6J Williams, A Samdani, HLA Defino e mais 3. Anticipation of vertebral pedicle breach through dynamic surgical guidance. Coluna/Columna, 2014no acervo →
- 7DD Bohl, BA Basques, NS Golinvaux e mais 4. Undertapping of Lumbar Pedicle Screws Can Result in Tapping With a Pitch That Differs From That of the Screw, Which Decreases Screw Pullout Force. Spine (Phila Pa 1976), 2015quem mais cita →
- 8D Ovadia, A Korn, M Fishkin e mais 3. The contribution of an electronic conductivity device to the safety of pedicle screw insertion in scoliosis surgery. Spine (Phila Pa 1976), 2011quem mais cita →
- 9EC Benzel. Biomechanics of Spine Stabilization. 2001quem mais cita →
- 10JJ Carmouche, RW Molinari, T Gerlinger e mais 2. Effects of pilot hole preparation technique on pedicle screw fixation in different regions of the osteoporotic thoracic and lumbar spine. J Neurosurg Spine, 2005quem mais cita →
- 11HLA Defino, RC Rosa, P Silva e mais 3. The effect of repetitive pilot-hole use on the insertion torque and pullout strength of vertebral system screws. Spine (Phila Pa 1976), 2009quem mais cita →
- 12CA Lill, E Schneider, J Goldhahn e mais 2. Mechanical performance of cylindrical and dual core pedicle screws in calf and human vertebrae. Arch.Orthop Trauma Surg, 2006quem mais cita →
- 13EC Benzel. Implant-bone interfaces. Biomechanics of Spinal Stabilization, 2001quem mais cita →
- 14P Silva, RC Rosa, AC Shimano e mais 3. Avaliação biomecânica da influência do macheamento e do desenho dos parafusos cervicais. Rev Bras Ortop, 2009no acervo →
- 15J Schatzker, R Sanderson e JP Murnaghan. The holding power of orthopedic screws in vivo. Clin Orthop Relat Res, 1975quem mais cita →
- 16P Silva, RC Rosa, AC Shimano e mais 1. Effect of pilot hole on biomechanical and in vivo pedicle screw-bone interface. Eur Spine J, 2013quem mais cita →
- 17S Erkan, B Hsu, C Wu e mais 3. Alignment of pedicle screws with pilot holes can tapping improve screw trajectory in thoracic spines?. Eur Spine J, 2010quem mais cita →
- 18RL Uhl. The biomechanics of screws. Orthop Rev, 1989quem mais cita →
- 19TM Shea, J Laun, SA Gonzalez-Blohm e mais 4. Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae current status. Biomed Res Int, 2014quem mais cita →
- 20HLA Defino, RF Miranda, RP Pinheiro e mais 1. Influência do diâmetro e geometria no macheamento do orifício piloto nos parafusos pediculares. Coluna/Columna [online], 2019quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda