  1. Can we expect similar behavior among CuNiTi 35°C wires?

    Ariane Salgado GONZAGA, David Salgado GONZAGA, Hallissa SIMPLÍCIO e mais 3Dental Press Journal of Orthodontics2021

    ABSTRACT Objective: This paper aims to verify the thermodynamic, mechanical and chemical properties of CuNiTi 35ºC commercial wires. Methods: Forty pre-contoured copper-nickel-titanium thermodynamic 0.017 x 0.025-in archwires with an Af temperature of 35°C were used. Eight wires from five different manufacturers…

  2. Effects of stress relaxation in beta-titanium cantilevers used in orthodontic mechanics

    Helder B. JACOB, Ariane S. GONZAGA, Brittany TRINH e mais 2Dental Press Journal of Orthodontics2021

    ABSTRACT Objective: This study evaluated the force decay and design shape changes caused by stress relaxation in two different orthodontic cantilever configurations. Methods: Eighty cantilevers made of 0.017 x 0.025-in beta-titanium wires were standardized in a passive position, using real scale templates, and…

  3. Effect of heat treatment on stainless steel orthodontic wires

    Osmar Aparecido Cuoghi, Geraldo Francisco Kasbergen, Paulo Henrique dos Santos e mais 2Brazilian Oral Research2011citado por 2 artigos

    This study evaluated the effect of heat treatment on CrNi stainless steel orthodontic archwires. Half of forty archwires of each thickness - 0.014" (0.35 mm), 0.016" (0.40 mm), 0.018" (0.45 mm) and 0.020" (0.50 mm) (totalling 160 archwires) - were subjected to heat treatment while the remainder were not. All of the…

  4. Deflection and Flexural Strength Effects on the Roughness of Aesthetic-Coated Orthodontic Wires

    Cibele Gonçalves de Albuquerque, Américo Bortolazzo Correr, Giovana Cherubini Venezian e mais 3Brazilian Dental Journal2017

    Abstract The aim was to evaluate the flexural strength and the effects of deflection on the surface roughness of esthetic orthodontic wires. The sample consisted of 70 archwire 0.014-inch: polytetrafluorethylene (PTFE)-coated Nickel-Titanium (Niti) archwires (Titanol Cosmetic-TC, Flexy Super Elastic Esthetic-FSE…

  5. Mechanical properties of orthodontic wires on ceramic brackets associated with low friction ligatures

    Fernando KOIKE, Hiroshi MARUO, Rogério LACERDA-SANTOS e mais 2Revista de Odontologia da UNESP2017

    Abstract Introduction Few studies investigated the mechanical properties of orthodontic wires on ceramic brackets associated the ligatures. Objective This study aimed to compare the load-deflection of orthodontic wires with round section of 0.016” made of stainless steel (SS), nickel-titanium (NiTi) and glass…

  6. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets

    Manoela Fávaro Francisconi, Guilherme Janson, José Fernando Castanha Henriques e mais 1Journal of Applied Oral Science2016citado por 3 artigos

    ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual…

  7. Corrosion evaluation of orthodontic wires in artificial saliva solutions by using response surface methodology

    Arianne Madureira Barcelos, Aderval Severino Luna, Nancy de Assis Ferreira e mais 3Materials Research2013citado por 1 artigo

    In the present work, stainless steel and Ni-Ti commercial orthodontic wires were immersed in artificial saliva solutions, containing or not F- ions, in different pH values, during 30 days. The weight loss and the Ni2+ content in the solutions at 15 and 30 days of exposition were evaluated using a composite design 2³…

  8. Antimicrobial Orthodontic Wires Coated with Silver Nanoparticles

    Isabella Salgado Gonçalves, Ana Beatriz Viale, Natália Navarro Sormani e mais 6Brazilian Archives of Biology and Technology2020citado por 1 artigo

    Abstract Conventional orthodontic treatment with the use of stainless steel may be detrimental to oral health by promoting demineralizing lesions appearance and increasing adhesion and formation of bacterial biofilm, inducing the development of cavities. An alternative that has been researched to reduce the side…

  9. Evaluation of friction in metal, ceramic and self-ligating brackets submitted to sliding mechanics

    Aryadne Cipreste MASCARELO, Ana Paula GODOI, Vivian FURLETTI e mais 2Revista de Odontologia da UNESP2018

    Abstract Objective With the purpose of evaluating the best results for a proposed orthodontic treatment, the aim of this research was to verify the frictional force between archwires and orthodontic brackets in sliding mechanics. Material and method Three different types of brackets were used: conventional metal…

  10. Evaluation of friction produced by self-ligating, conventional and Barbosa Versatile brackets

    Jurandir Antonio BARBOSA, Carlos Nelson ELIAS e Roberta Tarkany BASTINGRevista de Odontologia da UNESP2016citado por 1 artigo

    Abstract Introduction The Barbosa Versatile bracket design may provide lower frictional force and greater sliding. However, no in vitro studies have shown its sliding mechanisms and frictional resistance, particularly in comparison with other self-ligating or conventional brackets. Objective To compare the frictional…

  11. Attractiveness of different esthetic orthodontic wires

    Deric Meschiari Batista, Melissa Faccini, Fabricio Pinelli Valarelli e mais 4Dental Press Journal of Orthodontics2020

    ABSTRACT Objective: The aim of this study was to evaluate the attractiveness of different types of esthetic orthodontic wires by laypeople and dentists. Methods: Five different types of orthodontic wires were evaluated: three esthetic wires (Teflon-coated, epoxy resin-coated and rhodium-coated wires), and two metallic…

  12. Does the initial surface roughness of different CuNiTi wires affect the frictional resistance?

    Bernardo Brenner Pentagna, Viviane Veroni Degan, Ana Paula Terossi de Godoi e mais 3Brazilian Dental Journal2023

    Abstract This study aimed to assess and correlate initial surface roughness and frictional resistance of rectangular CuNiTi wires inserted in different self-ligating brackets. The sample consisted of 40 bracket-wire sets (rectangular CuNiTi wires of 0.017" x 0.025" and passive self-ligating brackets) divided into four…

  13. Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

    Maria Regina Guerra MONTEIRO, Licinio Esmeraldo da SILVA, Carlos Nelson ELIAS e mais 1Journal of Applied Oral Science2014citado por 1 artigo

    Objective: To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. Material and Methods: Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini…

  14. Friction between different wire bracket combinations in artificial saliva: an in vitro evaluation

    Tatiana Kelly da Silva Fidalgo, Matheus Melo Pithon, José Vinicius Bolognesi Maciel e mais 1Journal of Applied Oral Science2011citado por 4 artigos

    OBJECTIVE: The objective this work was to assess the friction coefficient between brackets and wires of different materials under conditions simulating the oral environment. MATERIAL AND METHODS: Stainless steel (SS) and titanium-molybdenum alloy (TMA) wires of 0.019x0.025-in diameter (American Orthodontics) and…

  15. Evaluation of frictional forces between ceramic brackets and archwires of different alloys compared with metal brackets

    Ariana Pulido Guerrero, Odilon Guariza Filho, Orlando Tanaka e mais 2Brazilian Oral Research2010

    The aim of this study was to evaluate, in vitro, frictional forces produced by ceramic brackets and arch wires of different alloys. Frictional tests were performed on three ceramic brackets: monocrystalline (Inspire ICE), polycrystalline (InVu), polycrystalline with metal slot (Clarity), and one stainless steel…

  16. Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires

    Fabio Schemann-Miguel, Flávio Cotrim-Ferreira, Alessandra Motta Streva e mais 2Dental Press Journal of Orthodontics2012

    OBJECTIVE: This study compared the load-deflection ratios between 0.019 x 0.025-in rectangular orthodontic wires using 5 conventional preformed nickel-titanium (NiTi) and 5 heat-activated NiTi archwires from four different manufacturers (Abzil, Morelli, 3M Unitek and Ormco), totaling 40 archwires. The archwires were…

  17. Do laypersons perceive aesthetic differences between coated and uncoated orthodontic archwires?

    Célia Regina Maio Pinzan-Vercelino, Ricardo Gabriel Calvet Campelo, Claudia Gonçalves Fahd e mais 3Dental Press Journal of Orthodontics2019citado por 1 artigo

    ABSTRACT Introduction: Aesthetic brackets are routinely combined with metallic wires in fixed orthodontic therapy, mainly due to the disadvantages of the clinical use of aesthetic archwires. The current situation needs to be explored in the literature by considering laypersons’ perceptions. Objective: The objective of…

  18. Clinical evaluation of dental alignment and leveling with three different types of orthodontic wires

    Marco Abdo Gravina, Ione Helena Vieira Portella Brunharo, Marcelo Reis Fraga e mais 4Dental Press Journal of Orthodontics2013citado por 1 artigo

    INTRODUCTION: A wide variety of orthodontic wires made of different alloys is available to be used in orthodontic practice and may produce different clinical responses during tooth movement. OBJECTIVE: This research evaluated the alignment and leveling of lower dental arches after the use of three types of orthodontic…

  19. Bracket/wire play: what to expect from tipping prescription on pre-adjusted appliances

    Leopoldino Capelozza Filho, Fabricio Monteiro de Castro Machado, Terumi Okada Ozawa e mais 2Dental Press Journal of Orthodontics2012

    INTRODUCTION: The opinion on the 'straight-wire' concept has been evolving since its origin, characterized by faithful followers or absolute skepticism. Currently, it seems reasonable to state that most professionals have a more realistic and critical viewpoint, with an attitude that reveals Orthodontics' maturity and…

  20. Differences in the force system delivered by different beta-titanium wires in elaborate designs

    Renato Parsekian Martins, Sergei Godeiro Fernandes Rabelo Caldas, Alexandre Antonio Ribeiro e mais 3Dental Press Journal of Orthodontics2015

    Abstract Objective: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. Methods: A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA III WIRETM (G3) and…