Journal of Applied Oral Science2011

Friction between different wire bracket combinations in artificial saliva: an in vitro evaluation

Tatiana Kelly da Silva Fidalgo, Matheus Melo Pithon, José Vinicius Bolognesi Maciel e Ana Maria Bolognese

em inglês

citado por 4 artigoscita 30 obras, 2 no acervo

resumo

OBJECTIVE: The objective this work was to assess the friction coefficient between brackets and wires of different materials under conditions simulating the oral environment. MATERIAL AND METHODS: Stainless steel (SS) and titanium-molybdenum alloy (TMA) wires of 0.019x0.025-in diameter (American Orthodontics) and polycarbonate bracket (American Orthodontics), ceramic bracket (American Orthodontics), and metal bracket (3M Unitek) with slots of 0.022x0.030-in were used. The friction coefficient was assessed by means of mechanical traction with the system immersed in artificial saliva. The mean roughness of both wire surface and bracket slots was evaluated by using a surface profilometer. RESULTS: The system using TMA wire and polycarbonate bracket had the highest roughness (p<0.05). SS wire with ceramic bracket had the highest friction coefficient, whereas the use of metallic bracket yielded the lowest (p<0.05). However, it was observed a statistically significant difference in the system using TMA wire and ceramic bracket compared to that using TMA wire and polycarbonate bracket (p=0.038). CONCLUSIONS: Ceramic brackets in association with SS wire should be judiciously used, since this system showed a high friction coefficient.

como citar · ABNT NBR 6023

FIDALGO, Tatiana Kelly da Silva et al. Friction between different wire bracket combinations in artificial saliva: an in vitro evaluation. Journal of Applied Oral Science, 2011. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572011000100012. Acesso em: 27 nov. 2026.

Referências

30 obras citadas · 2 no acervo

  1. 1S Al-Khatib, A Berradja, JP Celis e mais 1. In vitro friction of stainless steel arch wire-bracket combinations in air and different aqueous solutions. Orthod Craniofac Res, 2005quem mais cita →
  2. 2T Baccetti, L Franchi, M Camporesi e mais 2. Forces produced by different nonconventional bracket or ligature systems during alignment of apically displaced teeth. Angle Orthod, 2009quem mais cita →
  3. 3TG Bortoly, AP Guerrero, RN Rached e mais 3. Sliding resistance with esthetic ligatures: an in-vitro study. Am J Orthod Dentofacial Orthop, 2008quem mais cita →
  4. 4SJ Burrow. Friction and resistance to sliding in orthodontics: a critical review. Am J Orthod Dentofacial Orthop, 2009quem mais cita →
  5. 5V Cacciafesta, MF Sfondrini, A Ricciardi e mais 3. Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations. Am J Orthod Dentofacial Orthop, 2003quem mais cita →
  6. 6V Cacciafesta, MF Sfondrini, A Scribante e mais 2. Evaluation of friction of conventional and metal-insert ceramic brackets in various bracket-archwire combinations. Am J Orthod Dentofacial Orthop, 2003quem mais cita →
  7. 7A Cash, R Curtis, D Garrigia-Majo e mais 1. A comparative study of the static and kinetic frictional resistance of titanium molybdenum alloy archwires in stainless steel brackets. Eur J Orthod, 2004quem mais cita →
  8. 8CA Claro, J Abrão e SA Reis. Forces in stainless steel, TiMolium and TMA intrusion arches, with different bending magnitudes. Braz Oral Res, 2007no acervo →
  9. 9DH Damon. The Damon low-friction bracket: a biologically compatible straight-wire system. J Clin Orthod, 1998quem mais cita →
  10. 10A Downing, J McCabe e P Gordon. A study of frictional forces between orthodontic brackets and archwires. Br J Orthod, 1994quem mais cita →
  11. 11T Eliades. Orthodontic materials research and applications: part 2. Current status and projected future developments in materials and biocompatibility. Am J Orthod Dentofacial Orthop, 2007quem mais cita →
  12. 12P Gandini, L Orsi, C Bertoncini e mais 2. In vitro frictional forces generated by three different ligation methods. Angle Orthod, 2008quem mais cita →
  13. 13G Janson, FR Maria, SE Barros e mais 2. Orthodontic treatment time in 2- and 4-premolar-extraction protocols. Am J Orthod Dentofacial Orthop, 2006quem mais cita →
  14. 14A Karamouzos, AE Athanasiou e MA Papadopoulos. Clinical characteristics and properties of ceramic brackets: a comprehensive review. Am J Orthod Dentofacial Orthop, 1997quem mais cita →
  15. 15O Keith, SP Jones e EH Davies. The influence of bracket material, ligation force and wear on frictional resistance of orthodontic brackets. Br J Orthod, 1993quem mais cita →
  16. 16V Krishnan e KJ Kumar. Mechanical properties and surface characteristics of three archwire alloys. Angle Orthod, 2004quem mais cita →
  17. 17RP Kusy e JQ Whitley. Coefficients of friction for arch wires in stainless steel and polycrystalline alumina bracket slots: I. The dry state. Am J Orthod Dentofacial Orthop, 1990quem mais cita →
  18. 18RP Kusy e JQ Whitley. Effects of surface roughness on the coefficients of friction in model orthodontic systems. J Biomech, 1990quem mais cita →
  19. 19RP Kusy e JQ Whitley. Frictional resistances of metal-lined ceramic brackets versus conventional stainless steel brackets and development of 3-D friction maps. Angle Orthod, 2001quem mais cita →
  20. 20RP Kusy e JQ Whitley. Influence of archwire and bracket dimensions on sliding mechanics: derivations and determinations of the critical contact angles for binding. Eur J Orthod, 1999quem mais cita →