acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Orthodontic brackets”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Comparison between two methods for resin removing after bracket debonding

    Rodrigo De Marchi, Luciana Manzotti De Marchi, Raquel Sano Suga Terada e mais 1Dental Press Journal of Orthodontics2012citado por 1 artigo

    OBJECTIVE: The aim of this study was to assess - using scanning electron microscopy (SEM) - the effectiveness of two abrasive discs, one made from silicon and one from aluminum oxide, in removing adhesive remnants (AR) after debonding orthodontic brackets. METHODS: Ten randomly selected bovine teeth were used, i.e., 2…

  2. Effect of Yd:YAG laser irradiation on the shear bond strength of orthodontic metal brackets

    Fernando César Moreira, Helder Baldi Jacob, Luis Geraldo Vaz e mais 1Dental Press Journal of Orthodontics2020

    ABSTRACT Objective: The purpose of this study was to evaluate the effect of the Yd:YAG laser irradiation on orthodontic bracket base surface. Shear bond strength (SBS) values and sites of the bonding failure interfaces were quantified. Methods: Brackets were divided into two groups: OP (One Piece - integral sandblast…

  3. Comparative study of frictional forces generated by NiTi archwire deformation in different orthodontic brackets: In vitro evaluation

    Gilberto Vilanova Queiroz, Rafael Yagüe Ballester, João Batista De Paiva e mais 2Dental Press Journal of Orthodontics2012

    INTRODUCTION: The purpose of this study was to compare the frictional forces between 0.014-in NiTi wires (Aditek) with 4 mm horizontal deflection and brackets with different archwire ligation systems. METHODS: Four types of self-ligating brackets (Damon MX, Easy Clip, Smart Clip and In-Ovation), a triple bracket…

  4. Evaluation of the prototype of a new bracket-positioning gauge

    Sergio Luiz Mota Júnior, Marcio José da Silva Campos, Carina Abrantes Schmitberger e mais 3Dental Press Journal of Orthodontics2018

    ABSTRACT Objective: The purposes of this study were to present a prototype of a bracket-positioning gauge, which makes vertical inclination of the instrument difficult, allowing a reduction of vertical bracket positioning error, and to test its accuracy in bracket positioning by groups of individuals with different…

  5. Comparison of shear bond strength of orthodontic brackets bonded with a universal adhesive using different etching methods

    Fereshteh Shafiei, Ahmadreza Sardarian, Reza Fekrazad e mais 1Dental Press Journal of Orthodontics2019citado por 2 artigos

    ABSTRACT Objective: The aim of this study was to compare the effects of three enamel etching modes - laser-etch, self-etch and acid-etch (5, 10 and 15 s) - on bracket bonding, using a universal adhesive. Methods: Eighty-four maxillary premolars were randomly divided into seven groups (n=12) based on the etching method…

  6. Effect of two erosive protocols using acidic beverages on the shear bond strength of orthodontic brackets to bovine enamel

    Catielma Nascimento Santos, Felipe de Souza Matos, Sigmar de Mello Rode e mais 3Dental Press Journal of Orthodontics2018

    Abstract Objective: To assess the short-term effect of two in vitro erosive challenge protocols on the bond strength of metal orthodontic brackets on bovine enamel. Methods: Sixty bovine incisors were selected and randomly divided into six groups: AS7 (artificial saliva - 7 days, Control Group); CC7 (Coca-Cola™ - 7…

  7. Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires?

    José Rino Neto, Gilberto Vilanova Queiroz, João Batista de Paiva e mais 1Dental Press Journal of Orthodontics2013citado por 2 artigos

    OBJECTIVE: To compare hysteresis, activation and deactivation forces produced by first-order deformation of Contour 0.014-in NiTi wire (Aditek, Brazil) in four brands of self-ligating brackets: Damon MX, Easy Clip, Smart Clip and In-Ovation. METHODS: Activation and deactivation forces were measured in an Instron…

  8. Indirect orthodontic bonding - a modified technique for improved efficiency and precision

    Lincoln Issamu Nojima, Adriele Silveira Araújo e Matheus Alves JúniorDental Press Journal of Orthodontics2015citado por 4 artigos

    INTRODUCTION: The indirect bonding technique optimizes fixed appliance installation at the orthodontic office, ensuring precise bracket positioning, among other advantages. In this laboratory clinical phase, material and methods employed in creating the transfer tray are decisive to accuracy. OBJECTIVE: This article…

  9. Influence of surface treatment on shear bond strength of orthodontic brackets

    Ione Helena Vieira Portella Brunharo, Daniel Jogaib Fernandes, Mauro Sayão de Miranda e mais 1Dental Press Journal of Orthodontics2013citado por 2 artigos

    INTRODUCTION: The shear bond strength of orthodontic brackets bonded to micro-hybrid and micro-particulate resins under different surface treatment methods was assessed. METHODS: Two hundred and eighty test samples were divided into 28 groups (n = 10), where 140 specimens were filled with Durafill micro-particulate…

  10. Dentoalveolar mandibular changes with self-ligating versus conventional bracket systems: A CBCT and dental cast study

    Marcio Rodrigues de Almeida, Cristina Futagami, Ana Cláudia de Castro Ferreira Conti e mais 2Dental Press Journal of Orthodontics2015citado por 3 artigos

    OBJECTIVE: The aim of the present study was to compare dentoalveolar changes in mandibular arch, regarding transversal measures and buccal bone thickness, in patients undergoing the initial phase of orthodontic treatment with self-ligating or conventional bracket systems. METHODS: A sample of 25 patients requiring…

  11. Comparative Analysis of Stiffness of Lingual Appliances: An in Vitro Study

    Paolo Albertini, Francesca Cremonini e Mario PalonePesquisa Brasileira em Odontopediatria e Clínica Integrada2021citado por 2 artigos

    ABSTRACT Objective: To analyze and compare the stiffness of different lingual appliances with different archwires. Material and Methods: The three-point bending test was used to analyze the stiffness of the lingual archwires for the different lingual systems: eBrace, Harmony, Incognito, and STb. The deflection load…

  12. Do dental bleaching sessions prior to orthodontic treatment change the bond strength of esthetic brackets?

    Samara Gasperoni PERCIANO, Diego Patrik Alves CARNEIRO, Patricia Rafaela dos SANTOS e mais 3Dental Press Journal of Orthodontics2021

    ABSTRACT Objective: The aim of this experimental in vitro study was to evaluate whether dental bleaching performed before orthodontic treatment change the shear bond strength (SBS) of monocrystalline and polycrystalline esthetic brackets. Methods: Sixty (60) bovine incisors teeth were used and randomly divided into…

  13. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets

    Rodrigo Hitoshi Higa, Nayara Thiago Semenara, José Fernando Castanha Henriques e mais 3Dental Press Journal of Orthodontics2016

    ABSTRACT Introduction: The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Material and Methods: Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and…

  14. The role of friction in orthodontics

    Mariana Ribeiro Pacheco, Wellington Corrêa Jansen e Dauro Douglas OliveiraDental Press Journal of Orthodontics2012citado por 2 artigos

    INTRODUCTION: Sliding mechanics is widely used during orthodontic treatment. One of the disadvantages of this mechanics is the friction generated at the bracket/archwire interface, which may reduce the amount of desired orthodontic movement obtained. Due to the application and great acceptance of this type of…

  15. Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots

    Gabriel Schmidt Dolci, Ana Maria Spohr, Eduardo Rigon Zimmer e mais 1Dental Press Journal of Orthodontics2013citado por 1 artigo

    OBJECTIVE: The purpose of this study was to evaluate the dimensions and surface characteristics of orthodontic wires and bracket slots of different commercial brands. METHODS: Thirty metallic brackets (0.022 x 0.028-in and 0.022 x 0.030-in) were divided in three groups: DYN/3M group = Dyna-Lock, 3M/Unitek (stainless…

  16. A comparative clinical study of the failure rate of orthodontic brackets bonded with two adhesive systems: conventional and self-etching primer (SEP)

    Gladys Cristina Dominguez, André Tortamano, Luiz Vicente de Moura Lopes e mais 2Dental Press Journal of Orthodontics2013citado por 1 artigo

    OBJECTIVE: This study compared the clinical performance of orthodontic brackets bonded with Transbond adhesive paste after two priming systems: a two-stage conventional system (acid etching + Transbond XT adhesive primer) and a singlestage self-etching primer (SEP) (Transbond Plus). METHODS: The sample comprised 480…

  17. Evaluation of an alternative technique to optimize direct bonding of orthodontic brackets to temporary crowns

    Francilena Maria Campos Santos Dias, Célia Regina Maio Pinzan-Vercelino, Rudys Rodolfo de Jesus Tavares e mais 3Dental Press Journal of Orthodontics2015citado por 2 artigos

    OBJECTIVE: To compare shear bond strength of different direct bonding techniques of orthodontic brackets to acrylic resin surfaces.METHODS: The sample comprised 64 discs of chemically activated acrylic resin (CAAR) randomly divided into four groups: discs in group 1 were bonded by means of light-cured composite resin…

  18. Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding Systems

    Albertini Paolo, Matteo Tremaroli, Francesca Cremonini e mais 1Pesquisa Brasileira em Odontopediatria e Clínica Integrada2021

    ABSTRACT Objective To evaluate the accuracy of three different digital bracket positioning systems, comparing vertical, mesiodistal and buccolingual accuracy. Material and Methods The same case was sent to Orapix, Insignia, and Orthocad systems and the brackets were bonded to the malocclusion models.Damon 3 MX…

  19. Bracket/wire play: what to expect from tipping prescription on pre-adjusted appliances

    Leopoldino Capelozza Filho, Fabricio Monteiro de Castro Machado, Terumi Okada Ozawa e mais 2Dental Press Journal of Orthodontics2012

    INTRODUCTION: The opinion on the 'straight-wire' concept has been evolving since its origin, characterized by faithful followers or absolute skepticism. Currently, it seems reasonable to state that most professionals have a more realistic and critical viewpoint, with an attitude that reveals Orthodontics' maturity and…

  20. Four chemical methods of porcelain conditioning and their influence over bond strength and surface integrity

    João Paulo Fragomeni Stella, Andrea Becker Oliveira, Lincoln Issamu Nojima e mais 1Dental Press Journal of Orthodontics2015

    OBJECTIVE: To assess four different chemical surface conditioning methods for ceramic material before bracket bonding, and their impact on shear bond strength and surface integrity at debonding.METHODS: Four experimental groups (n = 13) were set up according to the ceramic conditioning method: G1 = 37% phosphoric acid…