Dental Press Journal of Orthodontics2015
Differences in the force system delivered by different beta-titanium wires in elaborate designs
Renato Parsekian Martins, Sergei Godeiro Fernandes Rabelo Caldas, Alexandre Antonio Ribeiro, Luís Geraldo Vaz, Roberto Hideo Shimizu e Lídia Parsekian Martins
em inglês
resumo
Abstract Objective: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. Methods: A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA III WIRETM (G3) and BETA CNATM (G4). Forces and moments were recorded by a moment transducer, coupled to a digital extensometer indicator adapted to a testing machine, every 0.5 mm of deactivation from 5 mm of the initial activation. The moment-to-force (MF) ratio, the overlapping of the vertical extensions of the TLSs and the load-deflection (LD) ratio were also calculated. To complement the results, the Young's module (YM) of each wire was determined by the slope of the load-deflection graph of a tensile test. The surface chemical composition was also evaluated by an energy dispersive X-ray fluorescence spectrometer. Results: All groups, except for G2, produced similar force levels initially. G3 produced the highest LD rates and G1 and G4 had similar amounts of overlap of the vertical extensions of the TLSs in "neutral position". G1 and G3 delivered the highest levels of moments, and G2 and G3 produced the highest MF ratios. b-Ti wires from G3 produced the highest YM and all groups showed similar composition, except for G2. Conclusion: The four beta-titanium wires analyzed produced different force systems when used in a more elaborate design due to the fact that each wire responds differently to bends.
como citar · ABNT NBR 6023
MARTINS, Renato Parsekian et al. Differences in the force system delivered by different beta-titanium wires in elaborate designs. Dental Press Journal of Orthodontics, 2015. DOI: 10.1590/2177-6709.20.6.089-096.OAR.
Referências
24 obras citadas
- 1J Goldberg e CJ Burstone. An evaluation of beta titanium alloys for use in orthodontic appliances. J Dent Res, 1979quem mais cita →
- 2A Verstrynge, J Van Humbeeck e G Willems. In-vitro evaluation of the material characteristics of stainless steel and beta-titanium orthodontic wires. Am J Orthod Dentofacial Orthop, 2006quem mais cita →
- 3CJ Burstone e AJ Goldberg. Beta titanium: a new orthodontic alloy. Am J Orthod, 1980quem mais cita →
- 4AJ Goldberg e CJ Burstone. Status report on beta titanium orthodontic wires Council on Dental Materials, Instruments, and Equipment. J Am Dent Assoc, 1982quem mais cita →
- 5MT Donovan, JJ Lin, WA Brantley e mais 1. Weldability of beta titanium arch wires. Am J Orthod, 1984quem mais cita →
- 6S Kapila e R Sachdeva. Mechanical properties and clinical applications of orthodontic wires. Am J Orthod Dentofacial Orthop, 1989quem mais cita →
- 7E Johnson. Relative stiffness of beta titanium archwires. Angle Orthod, 2003quem mais cita →
- 8SR Juvvadi, V Kailasam, S Padmanabhan e mais 1. Physical, mechanical, and flexural properties of 3 orthodontic wires: an in-vitro study. Am J Orthod Dentofacial Orthop, 2010quem mais cita →
- 9CJ Burstone e HA Koenig. Optimizing anterior and canine retraction. Am J Orthod, 1976quem mais cita →
- 10J Chen, DL Markham e TR Katona. Effects of T-loop geometry on its forces and moments. Angle Orthod, 2000quem mais cita →
- 11MG Faulkner, P Fuchshuber, D Haberstock e mais 1. A parametric study of the force/moment systems produced by T-loop retraction springs. J Biomech, 1989quem mais cita →
- 12RP Martins, PH Buschang, LP Martins e mais 1. Optimizing the design of preactivated titanium T-loop springs with Loop software. Am J Orthod Dentofacial Orthop, 2008quem mais cita →
- 13RF Viecilli. Self-corrective T-loop design for differential space closure. Am J Orthod Dentofacial Orthop, 2006quem mais cita →
- 14KD Hoenigl, J Freudenthaler, MR Marcotte e mais 1. The centered T-loop: a new way of preactivation. Am J Orthod Dentofacial Orthop, 1995quem mais cita →
- 15AJ Kuhlberg e CJ Burstone. T-loop position and anchorage control. Am J Orthod Dentofacial Orthop, 1997quem mais cita →
- 16C Manhartsberger, JY Morton e CJ Burstone. Space closure in adult patients using the segmented arch technique. Angle Orthod, 1989quem mais cita →
- 17RP Martins, PH Buschang, R Viecilli e mais 1. Curvature versus v-bends in a group B titanium T-loop spring. Angle Orthod, 2008quem mais cita →
- 18SG Caldas, RP Martins, MR Galvão e mais 2. Force system evaluation of symmetrical beta-titanium T-loop springs preactivated by curvature and concentrated bends. Am J Orthod Dentofacial Orthop, 2011quem mais cita →
- 19Y Lim, A Quick, M Swain e mais 1. Temperature effects on the forces, moments and moment to force ratio of nickel-titanium and TMA symmetrical T-loops. Angle Orthod, 2008quem mais cita →
- 20D Rose, A Quick, M Swain e mais 1. Moment-to-force characteristics of preactivated nickel-titanium and titanium-molybdenum alloy symmetrical T-loops. Am J Orthod Dentofacial Orthop, 2009quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda