acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Renato Parsekian Martins”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Welding strength of NiTi wires

    Tatyane Ribeiro Mesquita, Lídia Parsekian Martins e Renato Parsekian MartinsDental Press Journal of Orthodontics2018

    ABSTRACT Objective: To identify the appropriate power level for electric welding of three commercial brands of nickel-titanium (NiTi) wires. Methods: Ninety pairs of 0.018-in and 0.017 × 0.025-in NiTi wires were divided into three groups according to their manufacturers - GI (Orthometric, Marília, Brazil), GII (3M…

  2. Deformation of nickel-titanium closed coil springs: an in vitro study

    Camilla Ivini Viana Vieira, José Maurício dos Santos Nunes Reis, Luiz Geraldo Vaz e mais 2Dental Press Journal of Orthodontics2017

    ABSTRACT Objective: The aim of this paper was to determine the amount of deformation in four commercial brands of nickel-titanium closed springs. Methods: A total of 130 springs were divided into 13 subgroups, according to their features and manufacturers (Morelli, Orthometric, Ormco and GAC) and activated from 100%…

  3. Superelasticity and force plateau of nickel-titanium springs: an in vitro study

    Camila Ivini Viana Vieira, Sergei Godeiro Fernandes Rabelo Caldas, Lídia Parsekian Martins e mais 1Dental Press Journal of Orthodontics2016citado por 2 artigos

    abstract Objective: This paper analyzed whether nickel-titanium closed coil springs (NTCCS) have a different superelastic (SE) behavior according to activation and whether their force plateau corresponds to that informed by the manufacturer. Methods: A total of 160 springs were divided into 16 subgroups according to…

  4. Stability of beta-titanium T-loop springs preactivated by gradual curvature

    Sergei Godeiro Fernandes Rabelo Caldas, Renato Parsekian Martins, Marcela Emílio de Araújo e mais 3Dental Press Journal of Orthodontics2017citado por 1 artigo

    ABSTRACT Objective: Evaluate changes in the force system of T-Loop Springs (TLS) preactivated by curvature, due to stress relaxation. Methods: Ninety TLSs measuring 6 x 10 mm, produced out with 0.017 x 0.025-in TMA® wire and preactived by gradual curvature, were randomly distributed into nine groups according to time…

  5. Avaliação cefalométrica do tratamento da Classe II, divisão 1, de Angle com os aparelhos extrabucal de Kloehn e fixo edgewise: influência do padrão facial

    Lídia Parsekian Martins, Ary dos Santos Pinto, Luiz Gonzaga Gandini Júnior e mais 2Revista Dental Press de Ortodontia e Ortopedia Facial2004

    O presente estudo foi realizado com o propósito de avaliar respostas cefalométricas ao tratamento com aparelho extrabucal de Kloehn associado ao aparelho fixo edgewise convencional. Telerradiografias iniciais (T1) e finais (T2) de dois grupos de 30 pacientes tratados com estes aparelhos foram selecionadas e definidas…

  6. Differences in the force system delivered by different beta-titanium wires in elaborate designs

    Renato Parsekian Martins, Sergei Godeiro Fernandes Rabelo Caldas, Alexandre Antonio Ribeiro e mais 3Dental Press Journal of Orthodontics2015

    Abstract Objective: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. Methods: A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA III WIRETM (G3) and…

  7. Selected clinical approaches for the treatment of classic Class II, division 1 malocclusion

    Orlando Motohiro TANAKA, Gil Guilherme GASPARELLO, Matheus Melo PITHON e mais 2Dental Press Journal of Orthodontics2026

    ABSTRACT Introduction: Class II, division 1 malocclusion is the most common sagittal discrepancy, marked by distal positioning of the lower teeth, upper incisor protrusion, maxillary constriction, and facial profile imbalance. Its multifactorial etiology-skeletal, dental, and functional - results in diverse clinical…

  8. Achieving optimal orthodontic results with hybrid strategies: leveraging the synergy of aligners and fixed appliances

    Renato Parsekian MARTINSDental Press Journal of Orthodontics2025

    ABSTRACT Introduction: Despite their aesthetic appeal and rising popularity, clear aligners face significant limitations in performing complex orthodontic movements such as anterior extrusion, severe rotations, and efficient molar distalization. These biomechanical challenges often result in longer treatment durations…

  9. Can we expect similar behavior among CuNiTi 35°C wires?

    Ariane Salgado GONZAGA, David Salgado GONZAGA, Hallissa SIMPLÍCIO e mais 3Dental Press Journal of Orthodontics2021

    ABSTRACT Objective: This paper aims to verify the thermodynamic, mechanical and chemical properties of CuNiTi 35ºC commercial wires. Methods: Forty pre-contoured copper-nickel-titanium thermodynamic 0.017 x 0.025-in archwires with an Af temperature of 35°C were used. Eight wires from five different manufacturers…

  10. Early vertical correction of the deep curve of Spee

    Renato Parsekian MartinsDental Press Journal of Orthodontics2017citado por 2 artigos

    ABSTRACT Even though few technological advancements have occurred in Orthodontics recently, the search for more efficient treatments continues. This paper analyses how to accelerate and improve one of the most arduous phases of orthodontic treatment, i.e., correction of the curve of Spee. The leveling of a deep curve…

  11. Functional Aesthetic Occlusal Plane (FAOP)

    Carlos Alexandre Câmara e Renato Parsekian MartinsDental Press Journal of Orthodontics2016citado por 5 artigos

    ABSTRACT Introduction: A reasonable exposure of incisors and gingival tissues is generally considered more attractive than excess or lack of exposure. A reasonable gingival exposure is considered to be around 0 to 2 mm when smiling and 2-4 mm exposure of the maxillary incisor edge when the lips are at rest. Objective…