Brazilian Oral Research2010

Linear dimensional changes in plaster die models using different elastomeric materials

Jefferson Ricardo Pereira, Karina Yumi Murata, Accácio Lins do Valle, Janaina Salomon Ghizoni e Fábio Kenji Shiratori

em inglês

citado por 3 artigoscita 17 obras, 1 no acervo

resumo

Dental impression is an important step in the preparation of prostheses since it provides the reproduction of anatomic and surface details of teeth and adjacent structures. The objective of this study was to evaluate the linear dimensional alterations in gypsum dies obtained with different elastomeric materials, using a resin coping impression technique with individual shells. A master cast made of stainless steel with fixed prosthesis characteristics with two prepared abutment teeth was used to obtain the impressions. References points (A, B, C, D, E and F) were recorded on the occlusal and buccal surfaces of abutments to register the distances. The impressions were obtained using the following materials: polyether, mercaptan-polysulfide, addition silicone, and condensation silicone. The transfer impressions were made with custom trays and an irreversible hydrocolloid material and were poured with type IV gypsum. The distances between identified points in gypsum dies were measured using an optical microscope and the results were statistically analyzed by ANOVA (p < 0.05) and Tukey's test. The mean of the distances were registered as follows: addition silicone (AB = 13.6 µm, CD=15.0 µm, EF = 14.6 µm, GH=15.2 µm), mercaptan-polysulfide (AB = 36.0 µm, CD = 36.0 µm, EF = 39.6 µm, GH = 40.6 µm), polyether (AB = 35.2 µm, CD = 35.6 µm, EF = 39.4 µm, GH = 41.4 µm) and condensation silicone (AB = 69.2 µm, CD = 71.0 µm, EF = 80.6 µm, GH = 81.2 µm). All of the measurements found in gypsum dies were compared to those of a master cast. The results demonstrated that the addition silicone provides the best stability of the compounds tested, followed by polyether, polysulfide and condensation silicone. No statistical differences were obtained between polyether and mercaptan-polysulfide materials.

como citar · ABNT NBR 6023

PEREIRA, Jefferson Ricardo et al. Linear dimensional changes in plaster die models using different elastomeric materials. Brazilian Oral Research, 2010. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242010000300013. Acesso em: 27 nov. 2026.

Referências

17 obras citadas · 1 no acervo

  1. 1B. Millar. How to make a good impression (crown and bridge). Br Dent J., 2001quem mais cita →
  2. 2MR Dimashkieh e SM. Morgano. A procedure for making fixed prosthodontic impressions with the use of preformed crown shells. J Prosthet Dent., 1995quem mais cita →
  3. 3GH Johnson, LA Mancl, ER Schwedhelm e mais 2. Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays. J Prosthet Dent., 2010quem mais cita →
  4. 4TE Donovan e WW. Chee. Current concepts in gingival displacement. Dent Clin North Am., 2004quem mais cita →
  5. 5O Kumbuloglu, A User, S Toksavul e mais 1. Clinical evaluation of different gingival retraction cords. Quintessence Int., 2007quem mais cita →
  6. 6AJ. Cannistraci. A new approach to impression taking for crown and bridge. Dent Clin North Am., 1965quem mais cita →
  7. 7GJ. Livaditis. The matrix impression system for fixed prosthodontics. J Prosthet Dent., 1998quem mais cita →
  8. 8BS. Rubel. Impression materials: a comparative review of impression materials most commonly used in restorative dentistry. Dent Clin North Am., 2007quem mais cita →
  9. 9P Millstein, A Maya e C. Segura. Determining the accuracy of stock and custom tray impression/casts. J Oral Rehabil., 1998quem mais cita →
  10. 10TE Donovan e WW. Chee. A review of contemporary impression materials and techniques. Dent Clin North Am., 2004quem mais cita →
  11. 11JW Farah, AE Clark e PR. Ainpour. Elastomeric impression materials. Oper Dent., 1981quem mais cita →
  12. 12GH Johnson e RG. Craig. Accuracy of addition silicone as a function of technique. J Prosthet Dent., 1986quem mais cita →
  13. 13ACL Faria, RCS Rodrigues, AP Macedo e mais 2. Accuracy of stone casts obtained by different impression materials. Braz Oral Res., 2008no acervo →
  14. 14RW. Phillips. Skinner's science of dental materials. 1996quem mais cita →
  15. 15RA Walters e S. Spurrier. An effect of tray design and material retention on the linear dimensional changes in polysulfide impressions. J Prosthet Dent., 1990quem mais cita →
  16. 16GH Johnson e RG. Craig. Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of models. J Prosthet Dent., 1985quem mais cita →
  17. 17JL Boulton, JP Gage, PF Vincent e mais 1. A laboratory study of dimensional changes for three elastomeric impression materials using custom and stock trays. Aust Dent J., 1996quem mais cita →

Quem cita esta obra

3 artigos do acervo

ano a anomais citada em 2011 · 1 artigo
Mais citada em 2011, com 1 artigo.
  • 2011: citada em 1 artigo
  • 2012: citada em 1 artigo
  • 2019: citada em 1 artigo

quem fala desta obra

17 pessoas
ver as 17 pessoas e os artigos →