acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Dental impression technique”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Dimensional Accuracy of Stone Casts Made from Silicone-Based Impression Materials and Three Impression Techniques

    Rafael Pino Vitti, Marcos Aurélio Bomfim da Silva, Rafael Leonardo Xediek Consani e mais 1Brazilian Dental Journal2013citado por 1 artigo

    The aim of this study was to measure and compare the dimensional accuracy of stone casts of a partially edentulous mandibular arch made by two condensation silicones, two addition silicones and three impression techniques (1-step putty/light-body, 2-step putty/light-body and monophase technique). A partially…

  2. Effect of a cordless retraction paste on titanium surface: a topographic, chemical and biocompatibility evaluation

    Katherine Cooper, Vincent Bennani, Andrew Tawse-Smith e mais 3Brazilian Oral Research2013

    Good exposure of the preparation margins and haemostasis in the sulcular gingiva are necessary for accurate impressions to produce precise restorations. The use of cordless retraction paste material in implant dentistry is a relatively novel application. However, few studies have been conducted on the use of…

  3. Effect of a cordless retraction paste material on implant surfaces: an in vitro study

    Yin-Szu (Madison) Chang, Vincent Bennani, Andrew Tawse-Smith e mais 1Brazilian Oral Research2011citado por 2 artigos

    Cordless retraction paste material for gingival retraction in implant dentistry has recently become of interest to the clinician. However, few studies have been conducted on the use of retraction pastes and their possible interaction with implant surfaces. This in vitro study evaluated the effect of a cordless…

  4. Linear dimensional changes in plaster die models using different elastomeric materials

    Jefferson Ricardo Pereira, Karina Yumi Murata, Accácio Lins do Valle e mais 2Brazilian Oral Research2010citado por 3 artigos

    Dental impression is an important step in the preparation of prostheses since it provides the reproduction of anatomic and surface details of teeth and adjacent structures. The objective of this study was to evaluate the linear dimensional alterations in gypsum dies obtained with different elastomeric materials, using…

  5. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

    Adil Othman ABDULLAH, Effrosyni A TSITROU e Sarah POLLINGTONJournal of Applied Oral Science2016citado por 1 artigo

    ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation…

  6. Dimensional stability of a novel polyvinyl siloxane impression technique

    Moira Pedroso Leão, Camila Paloma Pinto, Ana Paula Sponchiado e mais 1Brazilian Journal of Oral Sciences2014citado por 1 artigo

    AIM: To introduce a modification of the reline impression technique (MRIT), and compare the dimensional changes of impressions obtained by MRIT and by conventional reline impression technique (CRIT).METHODS: An acrylic resin tablet was milled by a CAD-CAM system to simulate three abutments (A, B and C) with different…

  7. Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis

    Grazielle Franco Gomes, Mónica Estefanía Tinajero Aroni, Lucas Portela Oliveira e mais 3Brazilian Journal of Oral Sciences2023

    Aim To analyze the accuracy of extraoral systems (Ceramill Map400+, AutoScan-DS200+, and E2) in full implant-prosthetic rehabilitation three-dimensionally. Methods A metallic edentulous maxilla with four implants was digitalized by a contact scanner (MDX-40 - Roland, control) and used as a control image to compare…

  8. Accuracy of stone casts obtained by different impression materials

    Adriana Cláudia Lapria Faria, Renata Cristina Silveira Rodrigues, Ana Paula Macedo e mais 2Brazilian Oral Research2008citado por 6 artigos

    Several impression materials are available in the Brazilian marketplace to be used in oral rehabilitation. The aim of this study was to compare the accuracy of different impression materials used for fixed partial dentures following the manufacturers' instructions. A master model representing a partially edentulous…

  9. Evaluation of the accuracy of different transfer impression techniques for multiple implants

    Júlio César Brigolini de Faria, Laís Regiane Silva-Concílio, Ana Christina Claro Neves e mais 2Brazilian Oral Research2011citado por 1 artigo

    The aim of this study was to evaluate the accuracy of three implant transfer impression techniques. Four groups (n = 5) were defined, according to the technique: TC - tapered copings without splint; SC - square copings without splint; SCS - square copings splinted with dental floss and acrylic resin, and CG (control…

  10. Effect of techniques, trays and materials on accuracy of impressions clinically made

    Aion Mangino MESSIAS, Stephania Caroline Rodolfo SILVA, Filipe de Oliveira ABI-RACHED e mais 2Revista de Odontologia da UNESP2019

    Abstract Introduction Making accurate and dimensionally stable impressions to duplicate oral conditions and tooth morphology is an essential step of prosthetic dentistry for fabricating well-fitted indirect restorations and, consequently, ensure the longevity and success of the treatment. Several authors describe pros…

  11. Kennedy class III and IV dental arches: Trueness analysis of digitization methods and 3D-printing step

    Lucas Moreira Mendonça, Marianna Soares Nogueira Borges, Ayodele Alves Amorim e mais 2Brazilian Dental Journal2024

    Abstract This study aims to evaluate the trueness of Kennedy Class III and IV dental arches digitized by different methods and three-dimensionally (3D) printed using stereolithography technology in an in vitro setup. Reference casts (maxillary Kennedy class III and IV) were produced by computer assisted design and…

  12. Comparison of three instruments (compass, digital caliper and 3d software) for dental linear measurements on plaster and digitalized models of infants and children: an agreement and reproducibility study

    Patricia NADELMAN, Eduardo Otero Amaral VARGAS, Camila Silva de AMORIM e mais 3Dental Press Journal of Orthodontics2025

    ABSTRACT Objective: The aim of the study was to evaluate the reproducibility and agreement of dental linear measurements made directly on plaster models with a compass, and a digital caliper, compared to digital measurements made through software on the same plaster models after digitalization. Methods: 40 plaster…

  13. Is functional impression essential for the success of removable partial dentures?

    Bianca Tavares Rangel, Carolina Yoshi Campos Sugio, Amanda Aparecida Maia Neves Garcia e mais 3RGO - Revista Gaúcha de Odontologia2025

    ABSTRACT Removable partial dentures are a viable option for the rehabilitation of partially edentulous arches in dentistry. Their success depends on biological, mechanical, psychological, and technical factors, with the impression process being fundamental to achieving proper fit and patient comfort. Functional…

  14. Trueness comparison of various intraoral scanners and hybrid workflow for ceramic restoration

    Taksid CHARASSEANGPAISARN, Kritsaya SRIMAKHAJON, Suchanan SASIWILASAKORN e mais 3Journal of Applied Oral Science2025

    Abstract The scanned abutment file for the digital design of restorations can be either obtained directly using the intraoral scanner (IOS) or scanning the impression or the working model with the extraoral scanner (EOS). The trueness of the scanned file pertains to its effect on the accuracy of the restoration…

  15. Effect of Gingival Retraction Method to Lateral Gingival Displacement Width

    Apsari Indriyani, Chaidar Masulili e Roselani Widajati Luddin OdangPesquisa Brasileira em Odontopediatria e Clínica Integrada2019

    Abstract Objective: To analyze the efficacy of retraction cord with a hemostatic agent in comparison with retraction paste on lateral gingival displacement, to achieve the success of fixed dental prostheses (FDP). Material and Methods: Test samples included 32 teeth that required treatment with metal-porcelain FDP at…

  16. Dimensional accuracy of different impression techniques of partially edentulous mandibular arch

    Rafael Pino VITTI, Victor Pinheiro FEITOSA, Ataís BACCHI e mais 3RGO - Revista Gaúcha de Odontologia2017

    ABSTRACT Objective: The purpose of this in vitro study was to assess and compare the dimensional accuracy of three impression techniques: 1-step putty/light-body, 2-step putty/light-body, and the monophase technique. Methods: A partially edentulous standard stainless steel mandibular arch cast with reference points on…

  17. In vitro accuracy of digital versus conventional implant impressions for the all on four concept: a three dimensional analysis

    Monica Estefanía Tinajero Aroni, Raphael Ferreira de Souza Bezerra Araujo, Lucas Portela Oliveira e mais 3Brazilian Journal of Oral Sciences2026

    Aim To compare, in vitro, the three-dimensional accuracy of digital and conventional impression techniques for the All-on-Four concept. Methods A metal reference cast was fabricated to simulate an All-on-Four concept scenario. The cast was scanned using a contact scanner to serve as a control image. Subsequently, two…

  18. Cytotoxicity of alginate for orthodontic use

    Matheus Melo Pithon, Rogério Lacerda dos Santos, Fernanda Otaviano Martins e mais 1Dental Press Journal of Orthodontics2012

    OBJECTIVE: To evaluate the cytotoxicity of three different alginate impression materials for orthodontic use. METHODS: Three different brands of alginate were divided into three groups, namely, Group JCO (Jeltrate Chromatic Ortho), OP (Orthoprint) and CO (Cavex Orthotrace). Three control groups were also included…

  19. Effect of the disinfection technique on the linear dimensional stability of dental impression materials

    Sávio Marcelo Leite Moreira da Silva e Milton Carlos Gonçalves SalvadorJournal of Applied Oral Science2004citado por 2 artigos

    The purpose of this study was to evaluate the dimensional stability of heavy and light bodied condensation silicones after immersion in disinfectant solution for 10 or 20 minutes. The impression materials were Optosil Comfort and Xantopren VL Plus and the disinfectant solutions were 1% sodium hypochlorite and 2%…

  20. Can Different Impression Techniques Affect the Chewing Efficiency of Mandibular Implant-Retained Overdentures?

    Esmail Ahmed Abdel-Gawwad, Mostafa I. Fayad, Mohamed Abdullah Quassem e mais 3Brazilian Dental Journal2024

    Abstract Several impression techniques and theories have been developed for implant-retained overdentures, each with its own set of advantages and limitations. This study aimed to assess the chewing efficiency of mandibular implant-retained overdentures fabricated using three distinct impression techniques…