acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Dental prosthesis”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Impact of cement- and screw- retained implant prostheses on marginal bone loss: overview of systematic reviews

    João Vicente Calazans Neto, Cícero Andrade Sigilião Celles, Maria Helena Rossy Borges e mais 4Brazilian Journal of Oral Sciences2025

    Aim The choice between retention systems in implant-supported prostheses impacts marginal bone loss (MBL), a key factor for implant longevity. Due to variability in the findings of systematic reviews, this overview aims to assess the methodological quality and synthesize available evidence from systematic reviews on…

  2. Screwed and cement implant prosthesis: current clinical considerations

    Bruna Palmeira COSTA, Julliana Cariry Palhano FREIRE, Waleska Ohana de Souza MELO e mais 3RGO - Revista Gaúcha de Odontologia2021

    ABSTRACT Introduction: There is no consensus as to which cemented or screwed retention system is best to avoid bone loss around the implant from a fixed implant-supported restoration. Objective: To evaluate the prosthesis retention systems on screw and cemented implants, regarding: bone loss, survival and failure…

  3. Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis

    Grazielle Franco Gomes, Mónica Estefanía Tinajero Aroni, Lucas Portela Oliveira e mais 3Brazilian Journal of Oral Sciences2023

    Aim To analyze the accuracy of extraoral systems (Ceramill Map400+, AutoScan-DS200+, and E2) in full implant-prosthetic rehabilitation three-dimensionally. Methods A metallic edentulous maxilla with four implants was digitalized by a contact scanner (MDX-40 - Roland, control) and used as a control image to compare…

  4. Load-Application Devices: A Comparative Strain Gauge Analysis

    Renato Sussumu Nishioka, Luis Gustavo Oliveira de Vasconcellos, Renata Pilli Jóias e mais 1Brazilian Dental Journal2015

    In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and…

  5. Effect of veneering material on the deformation suffered by implant-supported fixed prosthesis framework

    Antônio Francisco GRANDO, Carlos Eduardo Edwards REZENDE, Edson Antônio Capello SOUSA e mais 1Journal of Applied Oral Science2014

    Knowing how stresses are dissipated on the fixed implant-supported complex allows adequate treatment planning and better choice of the materials used for prosthesis fabrication. Objectives: The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast…

  6. Total removal of the buccal flange in maxillary prosthetic preparation: a necessity?: case report

    Stephanie Gomes Assunção Alves, Lorena Gonçalves Alexandrino, Gustavo Eduardo Casagrande e mais 2RGO - Revista Gaúcha de Odontologia2024

    ABSTRACT Fixed implant-supported complete maxillary dentures aim to rehabilitate aesthetic, phonetic, and functional aspects of edentulous arches. A previous prosthetic preparation without a flange in the anterior sector makes it possible to evaluate the labial support and the existing space for the future prosthesis…

  7. Connecting accuracy of interchanged prosthetic abutments to different dental implants using scanning electron microscopy

    Piero Rocha Zanardi, Bruno Costa, Roberto Chaib Stegun e mais 3Brazilian Dental Journal2012citado por 2 artigos

    The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments…

  8. Success and survival rates of mandibular overdentures supported by two or four implants: a systematic review

    Isabelle de Sousa Dantas, Mariana Barbosa Câmara de Souza, Maria Helena de Siqueira Torres Morais e mais 2Brazilian Oral Research2014citado por 3 artigos

    This systematic review evaluated the influence played by the number of implants on the results of rehabilitation treatment with mandibular overdentures on 2 or 4 implants. The literature search was conducted using PubMed, Embase and Cochrane databases. Specific terms were used in performing a search from January 1980…

  9. Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis

    Luis Gustavo Oliveira de Vasconcellos, Renato Sussumu Nishioka, Luana Marotta Reis de Vasconcellos e mais 1Journal of Applied Oral Science2011citado por 2 artigos

    OBJECTIVES: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. MATERIAL AND METHODS: Three internal hexagon implants were linearly…

  10. Machined and plastic copings in three-element prostheses with different types of implantabutment joints: a strain gauge comparative analysis

    Renato Sussumu Nishioka, Lea Nogueira Braulino de Melo Nishioka, Celina Wanderley Abreu e mais 2Journal of Applied Oral Science2010citado por 2 artigos

    OBJECTIVE: Using strain gauge (SG) analysis, the aim of this in vitro study was quantify the strain development during the fixation of three-unit screw implant-supported fixed partial dentures, varying the types of implant-abutment joints and the type of prosthetic coping. The hypotheses were that the type of…

  11. Cost-effectiveness of implant-supported dental prosthesis compared to conventional dental prosthesis

    Livia Fernandes Probst, Tazio Vanni, Denise de Fátima Barros Cavalcante e mais 4Revista de Saúde Pública2019citado por 3 artigos

    ABSTRACT OBJECTIVE To conduct a cost-effectiveness analysis of alternatives for rehabilitation treatment of mandibular edentulism in the context of the Brazilian Unified Health System (implant-supported total dental prosthesis versus conventional total dental prosthesis). METHODS A Markov model was developed to…

  12. Evaluation of Factors Determining the Causes of Removable Partial Dentures Replacement

    Hanan Ali Hameed, Zainab Mahmood Al-Jammali e Mohammad Khursheed AlamPesquisa Brasileira em Odontopediatria e Clínica Integrada2025

    ABSTRACT Objective: To evaluate the correlation of different problems that lead to the replacement of removable partial dentures (RPD). Material and Methods: The sample included 231 patients with an RPD [Temale (n=120) and male (n=111)], age range (22-74) years. We take general information including name, age, gender…

  13. Biofilm Formation on Different Materials Used in Oral Rehabilitation

    Júlio C. M. Souza, Raquel R. C. Mota, Mariane B. Sordi e mais 3Brazilian Dental Journal2016

    Abstract The aim of this study was to evaluate the density and the morphological aspects of biofilms adhered to different materials applied in oral rehabilitation supported by dental implants. Sixty samples were divided into four groups: feldspar-based porcelain, CoCr alloy, commercially pure titanium grade IV and…

  14. Influence of metal bar lever-arm on screws detorque for dental prosthesis implant supported

    Wilson MATSUMOTO, Ana Paula MACEDO, Rossana Pereira de ALMEIDA e mais 2Revista de Odontologia da UNESP2020

    Abstract Introduction The cantilever length of implant-supported fixed prosthesis metal structure has been considered an important factor to transfer occlusion forces to the dental implant. Objective This study evaluated the influence of different extensions of cantilevers of Branemark protocol implant prosthesis when…

  15. Manufacturing Technique of an Impression Compound Applicator Gun

    Frederico Santos Lages, Lia Silva de Castilho, Danilo Rocha Dias e mais 1Pesquisa Brasileira em Odontopediatria e Clínica Integrada2025

    ABSTRACT Objective: To describe a practical way of applying impression compound in stick form using a safe electrical instrument. Material and Methods: Impression compound is a thermoplastic, rigid, reversible molding material in dentistry that requires a temperature of 55-60 °C for plasticization. Take a hot-glue gun…

  16. Relation between implant/abutment vertical misfit and torque loss of abutment screws

    Gustavo Augusto Seabra Barbosa, Sérgio Rocha Bernardes, Flávio Domingues das Neves e mais 3Brazilian Dental Journal2008citado por 6 artigos

    This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four…

  17. Implant/abutment vertical misfit of one-piece cast frameworks made with different materials

    Gustavo Augusto Seabra Barbosa, Flávio Domingues das Neves, Maria da Gloria Chiarello de Mattos e mais 2Brazilian Dental Journal2010citado por 4 artigos

    This study compared vertical and passive fit of one-piece cast frameworks made with 3 different materials: commercially pure titanium (CP Ti - G1), cobalt-chromium alloy (Co-Cr - G2) and nickel-chromium-titanium alloy (Ni-Cr-Ti - G3). Fifteen frameworks were obtained simulating bars for fixed prosthesis in a model…

  18. Failure of prosthetic screws on 971 implants

    Carolina Schäffer Morsch, Caroline Freitas Rafael, Juan Felipe Montero Dumes e mais 3Brazilian Journal of Oral Sciences2015

    Abstract Aim: To evaluate the presence of failures in prosthetic screws and whether these failures are related to the type of prosthesis, abutment angulation and presence or not of intermediate. Methods: Two-hundred and sixty-seven patients were evaluated at the Federal University of Santa Catarina, totaling 971…

  19. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

    Adil Othman ABDULLAH, Effrosyni A TSITROU e Sarah POLLINGTONJournal of Applied Oral Science2016citado por 1 artigo

    ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation…

  20. Effect of phosphate-bonded investments on titanium reaction layer and crown fit

    Sicknan Soares da Rocha, Fabiane Nogueira, Anelise Rodolfo Ferreira Pieralini e mais 2Brazilian Oral Research2010citado por 1 artigo

    This study analyzed the reaction layer and measured the marginal crown fit of cast titanium applied to different phosphate-bonded investments, prepared under the following conditions (liquid concentration/casting temperature): Rema Exakt (RE) - 100%/237°C, 75%/287°C, Castorit Super C (CS)-100%/70°C, 75%/141°C and…