Influence of Different Coronal Preflaring Protocols on Electronic Foramen Locators Precision
Andrélia Maciel Melo, Nilton Vivacqua-Gomes, Ricardo Affonso Bernardes, Rodrigo Ricci Vivan, Marco Antônio Húngaro Duarte e Bruno Carvalho de Vasconcelos
em inglês
citado por 1 artigocita 25 obras, 4 no acervo
resumo
Abstract: The aim of this study was to evaluate the influence of different coronal preflaring protocols (absent, conservative and conventional) on the accuracy of Root ZX II, Raypex 6, and RomiApex A-15 electronic foramen locators (EFLs). Twenty mandibular molars with Vertucci’s type IV mesial roots were subjected to endodontic exploration and foraminal patency confirmation. Under 16x magnification, its real lengths (RL) were measured and registered (RL1). The canals were then irrigated with 2.5% sodium hypochlorite and electronically measured (EM1) employing the alginate model; all measurements were performed in triplicate by a blind operator using adjusted endodontic hand-files introduced until the apex foramen. Coronal preflaring procedures were sequentially performed with #25/.06 (conservative) and #25/.12 (conventional) instruments; new RLs extents were performed after each coronal preparation protocol (RL2/RL3), as same as electronic measurements (EM2/EM3). The devices error (mm) was evaluated considering the difference between RLs and EMs at each preparation stage; their precision was stablished adopting ±0.5 mm as tolerance margin. The EFLs error significantly reduced after conventional coronal preflaring protocol (p<0.05), which not occur after the conservative one. The best precisions values were noted after conventional preparation as 90% (Root ZX II), 97.5% (Raypex 6), and 92.5% (RomiApex A-15). No significant differences were found in EFLs comparisons, regardless of the coronal protocol tested (p>0.05). Under the conditions tested it can be concluded that the EFLs evaluated were precise. Moreover, the preflaring protocols influences its accuracy’s, where the less conservative one produced the best results.
como citar · ABNT NBR 6023
MELO, Andrélia Maciel et al. Influence of Different Coronal Preflaring Protocols on Electronic Foramen Locators Precision. Brazilian Dental Journal, 2020. DOI: 10.1590/0103-6440202003282.
Referências
25 obras citadas · 4 no acervo
- 1D Riccuci e K Langeland. Apical limit of root canal instrumentation and obturation, part 2: histological study. Int Endod J, 1998quem mais cita →
- 2EH Ponce e JA Vilar Fernandez. The cemento-dentino-canal junction, the apical foramen and the apical constriction: evaluation by optical microscopy. J Endod, 2003quem mais cita →
- 3S Ravanshad, A Adl e J Anvar. Effect of working length measurement by electronic foramen locator or radiography on the adequacy of final working length: a randomized clinical trial. J Endod, 2010quem mais cita →
- 4BC Vasconcelos, MM Bueno, SM Luna-Cruz e mais 2. Accuracy of five electronic foramen locators with different operating systems: an ex vivo study. J Appl Oral Sci, 2013no acervo →
- 5I Tsesis, T Blazer, G Ben-Izhack e mais 3. The precision of electronic apex locators in working length determination: a systematic review and meta-analysis of the literature. J Endod, 2015quem mais cita →
- 6BC Vasconcelos, RD Verissimo-Chavez, N Vivacqua-Gomes e mais 3. Ex vivo evaluation of the accuracy of electronic foramen locators in root canals with an obstructed apical foramen. J Endod, 2015quem mais cita →
- 7BC Vasconcelos, LM Bastos, AS Oliveira e mais 3. Changes in root canal length determined during mechanical preparation stages and their relationship with the accuracy of Root ZX II. J Endod, 2016quem mais cita →
- 8L Marigo, L Gervasi, F Somma e mais 2. Comparison of two electronic foramen locators on human cadavers. Clin Oral Invest, 2016quem mais cita →
- 9TN Oliveira, N Vivacqua-Gomes, RA Bernardes e mais 3. Determination of the accuracy of 5 electronic Foramen locators in the function of different employment protocols. J Endod, 2017quem mais cita →
- 10AT Goes Cruz, C Wichnieski, E Carneiro e mais 3. Accuracy of 2 Endodontic Rotary Motors with Integrated Foramen locator. J Endod, 2017quem mais cita →
- 11D Altunbas, A Kustarcı e M Toyoglu. The Influence of various irrigants on the accuracy of 2 electronic foramen locators in locating simulated root perforations. J Endod, 2017quem mais cita →
- 12BC Vasconcelos, LA Matos, EC Pinheiro-Júnior e mais 2. Ex vivo accuracy of three electronic foramen locators using different apical file sizes. Braz Dent J, 2012quem mais cita →
- 13JL Ibarrola, BL Chapman, JH Howard e mais 2. Effect of preflaring on Root ZX foramen locators. J Endod, 1999quem mais cita →
- 14EJ Camargo, RO Zapata, PL Medeiros e mais 3. Influence of preflaring of the accuracy of length determination with four electronic Foramen locators. J Endod, 2009quem mais cita →
- 15M Brito-Júnior, CC Camilo, G Moreira-Júnior e mais 2. Effect of preflaring and file size on the accuracy of two electronic foramen locators. J Appl Oral Sci, 2012quem mais cita →
- 16GS Ibelli, JM Barroso, A Capelli e mais 2. Influence of cervical preflaring on apical file size determination in maxillary lateral incisors. Braz Dent J, 2007no acervo →
- 17K Yuan, C Niu, Q Xie e mais 3. Comparative evaluation of the impact of minimally invasive preparation vs. conventional straight-line preparation on tooth biomechanics: a finite element analysis. Eur J Oral Sci, 2016quem mais cita →
- 18R Krishan, F Paqué, A Ossareh e mais 3. Impacts of conservative endodontic cavity on root canal instrumentation efficacy and resistance to fracture assessed in incisors, premolars, and molars. J Endod, 2014quem mais cita →
- 19JR Vanni, R Santos, O Limongi e mais 3. Influence of cervical preflaring on determination of apical file size in maxillary molars: SEM analysis. Braz Dent J, 2005no acervo →
- 20AH Borges, TM Pereira, AN Porto e mais 3. The influence of cervical preflaring on the amount of apically extruded debris after root canal preparation using different instrumentation systems. J Endod, 2016quem mais cita →
Quem cita esta obra
1 artigo do acervo
quem fala desta obra
7 pessoas- Ricardo Affonso BERNARDESautocitação1 artigo · 2022
- Marco Antônio Hungaro DUARTEautocitação1 artigo · 2022
- Alinne Patierry Oliveira Pacifico FEIOSA1 artigo · 2022
- Jafra Carvalho FURTADO1 artigo · 2022
- Bruno Carvalho de VASCONCELOSautocitação1 artigo · 2022
- Nilton VIVACQUA-GOMESautocitação1 artigo · 2022
- Rodrigo Ricci VIVANautocitação1 artigo · 2022
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda