acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Rodrigo Ricci Vivan”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Effect of irrigant type, activation method, and contact time on dentin diffusion and ultrastructure

    Vanessa Abreu Sanches Marques Costa, Letycia Accioly Simões Coelho, Cláudia Cristina Biguetti e mais 7Brazilian Oral Research2026

    Abstract: This study aimed to evaluate the effects of different endodontic irrigation protocols on irrigant diffusion, dentin microhardness, and dentinal collagen organization. Bovine dentin specimens were irrigated with 2.5% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX), or 0.9% saline solution (SS) and…

  2. Removal of Obturation Material from Mesial Roots and Isthmus of Mandibular Molars by Activation of Irrigating Solution During Endodontic Retreatment: Micro-CT Analysis

    Eulália Mendes de Oliveira, Nathalie Murielly Rolim de Abreu, Alinne Patiery Pacífico Oliveira Feitosa e mais 5Pesquisa Brasileira em Odontopediatria e Clínica Integrada2026

    ABSTRACT Objective: To evaluate the effectiveness of high-volume irrigation and irrigant activation as methods to remove obturation material during endodontic retreatment in mesial canals of mandibular molars with isthmuses. Material and Methods: After micro-CT scanning, 30 mandibular molars were accessed, prepared…

  3. Evaluation of physicochemical and mechanical properties of two experimental premixed calcium silicate sealers

    Maria Carolina Guiotti de Oliveira, Stefani Jovedi Rosa, Bruno Carvalho de Vasconcelos e mais 3Brazilian Dental Journal2025

    Abstract The study aimed to evaluate the physicochemical properties of two experimental root canal sealers (CEO 1 and CEO 2) and compare them with Bio-C Sealer (BC) and AH Plus Bioceramic (AHPB). Setting time was evaluated following ISO 6876 Standard, radiopacity was assessed by radiographic analysis in millimeters of…

  4. Endodontic retreatment of curved canals using Reciproc, Hyflex CM and Prodesign Duo Hybrid Systems

    Amanda Garcia Alves MALIZA, Renata Maíra de Souza LEAL, Bruno Cavalini CAVENAGO e mais 3Brazilian Oral Research2025

    Abstract The aim of this ex vivo study was to evaluate the efficacy of the Reciproc, Hyflex CM, and ProDesign Duo Hybrid in the retreatment of mesial root canals with Vertucci Type 4 of mandibular molars with curvatures between 10 and 20 degrees. Forty-five mesial roots of mandibular molars were prepared up to size…

  5. Endodontists’ Self-Assessment about Pharmacological Strategies for Management of Endodontic Pain

    Letycia Accioly Simões Coelho, Marcos Dezotti Luiz, Artur Villas Bôas Weckwerth e mais 6Pesquisa Brasileira em Odontopediatria e Clínica Integrada2025

    ABSTRACT Objective: To assess the pharmacological strategies of a group of Brazilian endodontists regarding endodontic pain. Material and Methods: Specialists answered a questionnaire with two main themes: 1) Pharmacological prescription patterns and 2) Endodontic procedures and risk of postoperative pain. The…

  6. Influence of temperature on the torsional properties of two thermally treated NiTi rotary instruments

    Roberto Barreto Osaki, Clovis Monteiro Bramante, Rodrigo Ricci Vivan e mais 3Brazilian Dental Journal2023

    Abstract This study aimed to evaluate the influence of temperature on torsional strength and angular deflection of two experimental NiTi rotary instruments manufactured from Blue and Gold thermal treatments and with identical cross-sections. A total of 40 experimental NiTi instruments 25.06 and with a triangular…

  7. Divergence between confidence and knowledge of endodontists regarding non-odontogenic pain

    Marcos Dezotti LUIZ, Letycia Accioly Simões COELHO, Rodrigo Ricci VIVAN e mais 5Journal of Applied Oral Science2023

    Abstract This study aimed to assess the self-reported levels of confidence and knowledge related to non-odontogenic pain among a group of Brazilian endodontists. Methodology A total of one hundred and forty-six endodontists affiliated with the Brazilian Society of Endodontics participated in the survey. The…

  8. Laboratory study of tissue repair of resin-based endodontic sealers in critical surgical defects

    Guilherme Ferreira da SILVA, Letycia Accioly Simões COELHO, Vanessa Abreu Sanches COSTA e mais 6Journal of Applied Oral Science2022

    Abstract Filling materials should be restricted to the root canal space. However, sometimes it is impossible to control the apical extrusion, in this case, the fate of the filling material and the result of the treatment will depend on its physicochemical properties and biocompatibility. Objective To evaluate the…

  9. Root canal length changes during mechanical preparation due to different cervical enlargement patterns

    Jafra Carvalho FURTADO, Alinne Patierry Oliveira Pacifico FEIOSA, Nilton VIVACQUA-GOMES e mais 4Brazilian Oral Research2022

    Abstract This study aimed to evaluate the root canal real length (RL) changes due to the mechanical instrumentation use with different flaring magnitudes. After access cavity, 60 mesial root canals of mandibular molars were randomly separated in three groups: Hyflex EDM (HF; #25/.12, #10/.05 e #25/~), Reciproc Blue…

  10. Effect of nickel-titanium alloys on root canal preparation and on mechanical properties of rotary instruments

    Rodrigo Ricci VIVAN, Vanessa Abreu Sanches Marques COSTA, Leticia Citelli CONTI e mais 5Brazilian Oral Research2022citado por 1 artigo

    Abstract The aim of this study was to evaluate the quality of curved root canal preparation, torsional fatigue, and cyclic fatigue of rotary systems manufactured with different NiTi alloys. Ninety single-rooted canals with curvatures of 15° to 30o were scanned and divided into three groups according to the rotary…

  11. Evaluation of in vitro experimental model for analysis of bioceramic sealers

    Ericke Mucke SILVA, Murilo Priori ALCALDE, Rodrigo Ricci VIVAN e mais 3Brazilian Oral Research2022citado por 1 artigo

    Abstract This study aimed to evaluate physicochemical properties of three ready-to-use calcium silicate-based endodontic sealers: Endosequence BC Sealer, Bio C Sealer, and Sealer Plus BC. Radiopacity was evaluated using specimens of 10 mm in diameter and 1 mm in height, along with an aluminum step wedge. For the flow…

  12. Can kinematics, file diameter, and PUI influence the intracanal decontamination and apical bacterial extrusion?

    Maricel Rosario Cardenas Cuellar, Evelyn Giuliana Velásquez-Espedilla, Victor Feliz Pedrinha e mais 3Brazilian Oral Research2021

    Abstract: The present study investigated the intracanal decontamination and apical extrusion of bacteria and debris from root canals instrumented with rotary and reciprocating systems (ProDesign Logic or ProDesign R), with different file diameters and using conventional syringe irrigation (CSI) or passive ultrasonic…

  13. Evaluation of type of kinematics on glide path procedures and torsional fatigue resistance after preparation of moderately curved canals

    Murilo Priori Alcalde, Marco Antonio Hungaro Duarte, Pedro Henrique Souza Calefi e mais 4Brazilian Oral Research2021

    Abstract: Sixty moderately curved canals of mandibular molars classified as Vertucci’s type IV canal configuration were selected by micro-CT 1174. The teeth were divided into two groups according to the kinematics used, whether reciprocating or rotary motion (n=30, totaling 60 mesial root canals). The instruments used…

  14. Influence of Different Coronal Preflaring Protocols on Electronic Foramen Locators Precision

    Andrélia Maciel Melo, Nilton Vivacqua-Gomes, Ricardo Affonso Bernardes e mais 3Brazilian Dental Journal2020citado por 1 artigo

    Abstract: The aim of this study was to evaluate the influence of different coronal preflaring protocols (absent, conservative and conventional) on the accuracy of Root ZX II, Raypex 6, and RomiApex A-15 electronic foramen locators (EFLs). Twenty mandibular molars with Vertucci’s type IV mesial roots were subjected to…

  15. Knowledge about Coronavirus disease 19 (COVID-19) and its professional repercussions among Brazilian endodontists

    George Táccio de Miranda CANDEIRO, Giulio GAVINI, Rodrigo Ricci VIVAN e mais 3Brazilian Oral Research2020citado por 1 artigo

    Abstract The aim of this study was to assess Brazilian endodontists’ level of knowledge about the coronavirus disease (COVID-19) and examine its professional repercussions. The link to the online survey that was created for this study was shared with Brazilian endodontists through social networking applications. The…

  16. Ultrasonic tips as an auxiliary method for the instrumentation of oval-shaped root canals

    Melissa Esther RIVERA-PEÑA, Marco Antônio Húngaro DUARTE, Murilo Priori ALCALDE e mais 3Brazilian Oral Research2019citado por 4 artigos

    Abstract To evaluate the influence of novel ultrasonic tips as an auxiliary method for the rotary preparation of flattened/oval-shaped canals. Forty-five mandibular incisors were selected and divided into one of three experimental groups (n = 15): Group PFCP – ProDesign Logic 25/.05 + Flatsonic + Clearsonic +…

  17. Torsional fatigue strength of reciprocating and rotary pathfinding instruments manufactured from different NiTi alloys

    Rodrigo Ricci VIVAN, Murilo Priori ALCALDE, George CANDEIRO e mais 3Brazilian Oral Research2019citado por 2 artigos

    Abstract To evaluate the torsional properties of engine-driven pathfinding instruments manufactured from different NiTi alloys – R-Pilot (tip size 12.5;.04 taper; M-Wire) and One G (tip size 14;.03 taper; Conventional NiTi). A total of 40 NiTi instruments from engine-driven pathfinding instruments (n = 20) were used…

  18. Evaluation of Physicochemical Properties of New Calcium Silicate-Based Sealer

    Aline Teixeira Mendes, Paula Barcellos da Silva, Bruna Barcelos Só e mais 5Brazilian Dental Journal2018citado por 10 artigos

    Abstract This study aimed to evaluate the physicochemical properties of a calcium silicate-based sealer (Sealer Plus BC; MK Life, Porto Alegre, Brazil) compared with an epoxy-resin sealer (AH Plus; Dentsply DeTrey GmbH, Konstanz, Germany). Initial and final setting time was assessed based on ISO 6876:2012 and ASTM…

  19. Debris extrusion and foraminal deformation produced by reciprocating instruments made of thermally treated NiTi wires

    Myrna Maria Arcanjo Frota, Ricardo Affonso Bernardes, Rodrigo Ricci Vivan e mais 3Journal of Applied Oral Science2018citado por 3 artigos

    Abstract Objective To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different…

  20. Do different strains of E. faecalis have the same behavior towards intracanal medications in in vitro research?

    Rafaela Fernandes Zancan, Lyz Cristina Furquim Canali, Talita Tartari e mais 3Brazilian Oral Research2018

    Abstract: The aim of this study was to evaluate the antimicrobial action of different endodontic pastes against Enterococcus faecalis ATCC 29212, isolated from the urinary tract, and compare the action with E. faecalis ATCC 4083, isolated from the root canal. For this purpose, dentin blocks were infected for 21 days…