acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Nilton Vivacqua-Gomes”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. In vitro evaluation of the effectiveness of the chemomechanical preparation against Enterococcus faecalis after single- or multiple-visit root canal treatment

    Eduardo Diogo Gurgel-Filho, Nilton Vivacqua-Gomes, Brenda Paula Figueiredo de Almeida Gomes e mais 3Brazilian Oral Research2007citado por 2 artigos

    The purpose was to assess the elimination of Enterococcus faecalis in vitro in human mandibular premolars after chemomechanical preparation with or without the use of a calcium hydroxide dressing. After 60 days of contamination with E. faecalis, the root canals were prepared using the Crown-Down technique combined…

  2. Root canal length changes during mechanical preparation due to different cervical enlargement patterns

    Jafra Carvalho FURTADO, Alinne Patierry Oliveira Pacifico FEIOSA, Nilton VIVACQUA-GOMES e mais 4Brazilian Oral Research2022

    Abstract This study aimed to evaluate the root canal real length (RL) changes due to the mechanical instrumentation use with different flaring magnitudes. After access cavity, 60 mesial root canals of mandibular molars were randomly separated in three groups: Hyflex EDM (HF; #25/.12, #10/.05 e #25/~), Reciproc Blue…

  3. Influence of Different Coronal Preflaring Protocols on Electronic Foramen Locators Precision

    Andrélia Maciel Melo, Nilton Vivacqua-Gomes, Ricardo Affonso Bernardes e mais 3Brazilian Dental Journal2020citado por 1 artigo

    Abstract: The aim of this study was to evaluate the influence of different coronal preflaring protocols (absent, conservative and conventional) on the accuracy of Root ZX II, Raypex 6, and RomiApex A-15 electronic foramen locators (EFLs). Twenty mandibular molars with Vertucci’s type IV mesial roots were subjected to…

  4. Debris extrusion and foraminal deformation produced by reciprocating instruments made of thermally treated NiTi wires

    Myrna Maria Arcanjo Frota, Ricardo Affonso Bernardes, Rodrigo Ricci Vivan e mais 3Journal of Applied Oral Science2018citado por 3 artigos

    Abstract Objective To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different…

  5. Ex vivo accuracy of three electronic apex locators using different apical file sizes

    Bruno Carvalho de Vasconcelos, Leonardo de Alencar Matos, Elilton Cavalcante Pinheiro-Júnior e mais 2Brazilian Dental Journal2012citado por 5 artigos

    This study evaluated the accuracy of three electronic apex locators (Root ZX, Novapex, and Justy II) in root canal length determinations using different apical file sizes, considering the apical constriction (AC) and the major foramen (MF) as anatomic references. The diameter of the apical foramina of 40 single-rooted…

  6. Penetration of bioceramic and epoxy-resin endodontic cements into lateral canals

    George Táccio de Miranda Candeiro, Amanda Bezerra Lavor, Ilana Thaís de Freitas Lima e mais 4Brazilian Oral Research2019citado por 1 artigo

    Abstract: The aim of the present study was to assess the penetration capacity of two endodontic cements, Endosequence BC Sealer and AH Plus, in artificial lateral canals. Twenty-six two-rooted, maxillary first premolars were instrumented to size 40.06 using K3 files. In each root, six lateral canals of two diameters…