Arquivos Brasileiros de Oftalmologia2010
Interchangeability between Placido disc and Scheimpflug system: quantitative and qualitative analysis
Vinícius Silbiger de Stefano, Luiz Alberto Soares Melo Junior, Felipe Mallmann e Paulo Schor
em inglês
resumo
PURPOSE: Many systems try to replace Placido disc-based topographers, such as those based in Scheimpflug principles. The purpose of this study is to check if they are interchangeable. METHODS: Quantitative analysis evaluated data obtained from EyeSys and Pentacam, i.e. simulated keratometric values, in addition to flattest and steepest keratometric values. Sixty-three maps from each device (EyeSys scale=0.5 D; Pentacam scale= 0.25 D) were used for the comparison. Qualitative analysis selected 10 EyeSys and 15 Pentacam topographies used in the quantitative evaluation. Aspheric, keratoconus suspects (KS) and established keratoconus corneas were included. Four groups (children [CH], non-physicians adults [AD], residents in ophthalmology [OP] and refractive surgeons [RS]) were asked to match the topographies belonging to the same eye. RESULTS: Analysis showed that the parameters are correlated; however they are not clinically similar. In the qualitative analysis, the percent of correct matches increased when KS was removed. CH group was statistically different from every group in these comparisons. When only KS was considered, CH vs. OP, CH vs. RS and AD vs. RS remained statistically different. AD vs. OP showed no relevant difference in any comparison. CONCLUSIONS: The systems are not fully interchangeable, yet they are correlated. Practitioners who are adapting to Pentacam should use the 0.25 D scale maps and transform formulas that use EyeSys parameters. Only with persistent training may the topographies be properly matched; KS corneas are more difficult to be correctly paired.
como citar · ABNT NBR 6023
STEFANO, Vinícius Silbiger de et al. Interchangeability between Placido disc and Scheimpflug system: quantitative and qualitative analysis. Arquivos Brasileiros de Oftalmologia, 2010. DOI: 10.1590/S0004-27492010000400013.
Referências
24 obras citadas
- 1SK Rao e P Padmanabhan. Understanding corneal topography. Curr Opin Ophthalmol, 2000quem mais cita →
- 2FA Guarnieri e JC Guarnieri. Comparison of Placido-based, rasterstereography, and slit-scan corneal topography systems. J Refract Surg, 2002quem mais cita →
- 3MR Nilforoushan, M Speaker, M Marmor e mais 4. Comparative evaluation of refractive surgery candidates with Placido topography, Orbscan II, Pentacam, and wavefront analysis. J Cataract Refract Surg, 2008quem mais cita →
- 4Y Mejía-Barbosa e D Malacara-Hernández. A review of methods for measuring corneal topography. Optom Vis Sci, 2001quem mais cita →
- 5YS Rabinowitz. Keratoconus. Surv Ophthalmol, 1998
- 6G Cairns e CN McGhee. Orbscan computerized topography: attributes, applications, and limitations. J Cataract Refract Surg, 2005quem mais cita →
- 7WA Douthwaite e EA Mallen. Cornea measurement comparison with Orbscan II and EyeSys videokeratoscope. Optom Vis Sci, 2007quem mais cita →
- 8T Swartz, L Marten e M Wang. Measuring the cornea: the latest developments in corneal topography. Curr Opin Ophthalmol, 2007quem mais cita →
- 9SC Pflugfelder, Z Liu, W Feuer e mais 1. Corneal thickness indices discriminate between keratoconus and contact lens-induced corneal thinning. Ophthalmology, 2002quem mais cita →
- 10S Quisling, S Sjoberg, B Zimmerman e mais 2. Comparison of Pentacam and Orbscan IIz on posterior curvature topography measurements in keratoconus eyes. Ophthalmology, 2006quem mais cita →
- 11A Konstantopoulos, P Hossain e DF Anderson. Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?. Br J Ophthalmol, 2007quem mais cita →
- 12H Shankar, D Taranath, CT Santhirathelagan e mais 1. Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements. J Cataract Refract Surg, 2008quem mais cita →
- 13W Buehl, D Stojanac, S Sacu e mais 2. Comparison of three methods of measuring corneal thickness and anterior chamber depth. Am J Ophthalmol, 2006quem mais cita →
- 14SE Wilson e SD Klyce. Quantitative descriptors of corneal topography: A clinical study. Arch Ophthalmol, 1991quem mais cita →
- 15CG Arce, M Campos e P Schor. Determining corneal power using Orbscan II videokeratography for IOL calculation after excimer laser surgery for myopia. J Cataract Refract Surg, 2007quem mais cita →
- 16CG Arce, M Campos e P Schor. Overlooked features of corneal topographers. J Cataract Refract Surg, 2008quem mais cita →
- 17JM Bland e DG Altman. Measuring agreement in method comparison studies. Stat Methods Med Res, 1999quem mais cita →
- 18HJ Shammas, KJ Hoffer e MC Shammas. Scheimpflug photography keratometry readings for routine intraocular lens power calculation. J Cataract Refract Surg, 2009quem mais cita →
- 19G Savini, P Barboni, M Carbonelli e mais 1. Accuracy of Scheimpflug corneal power measurements for intraocular lens power calculation. J Cataract Refract Surg, 2009quem mais cita →
- 20G Savini, P Barboni, M Carbonelli e mais 1. Agreement between Pentacam and videokeratography in corneal power assessment. J Refract Surg, 2009quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda