acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Refractive surgical procedures”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Clinical evaluation of reprocessed blades in LASIK

    Felipe Mallmann, Celina Murata, Ester Sakae Yamazaki e mais 1Arquivos Brasileiros de Oftalmologia2008

    PURPOSE: To evaluate outcome and complications in LASIK with reprocessed blades. METHODS: Retrospective analysis of patients' charts submitted to complete custom LASIK from January 2004 to June 2005. Inclusion criteria comprised surgical description of blade use and minimum follow-up of 1 month. The blade was…

  2. Visual rehabilitation after LASIK complication: flap amputation, topo-guided surgery, and phacoemulsification

    Frederico França Marques, Daniel Filipe Oliveira Rabelo, Daniela Meira Villano Marques e mais 3Arquivos Brasileiros de Oftalmologia2024

    ABSTRACT We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable…

  3. Vertex distance variability of the Vision-S™ 700 refractors in normal population

    Alexandre Costa Neto, Jaime Guedes, Denisse J. Mora-Paez e mais 6Revista Brasileira de Oftalmologia2024

    ABSTRACT Objective: To study vertex-optical distance variation and estimate its impact on manifest refraction. Methods: Prospective study in a private clinic using the Vision-S™ 700 with five forehead positions. Forehead on the third position showed the closest vertex-optical distance of 12mm. Results: Analysis of 52…

  4. Clinical, tomographic, and biometric differences between regular and irregular astigmatism in Iraq refractive surgery candidates: a cross-sectional study

    Marrwan Hisham Mohmmed, Mustafa Tawfeeq Halboos e Noor HamadRevista Brasileira de Oftalmologia2026

    ABSTRACT Objective: To compare visual acuity, corneal tomography, and ocular biometry between regular and irregular astigmatism in Iraqi refractive surgery candidates and to examine relationships among key parameters. Methods: Retrospective cross-sectional study of consecutive adults screened for refractive surgery at…

  5. Centration in refractive surgery

    Lívia Cristina Rios, Patrícia Gomes da Silva, Aristófanes Mendonça Canamary Junior e mais 4Arquivos Brasileiros de Oftalmologia2020citado por 8 artigos

    ABSTRACT The point of centration for refractive surgery is a theme of great importance that generates considerable discussion among specialists and surgeons in the field. Notably, any changes in light can alter the size of the pupil, and the visual axis of the fixation line to the fovea is unique in each patient. A…

  6. Cyclotorsion measurement in laser refractive surgery

    Abrahão Rocha Lucena, Jório Almino de Alencar Arrais Mota, Descartes Rolim de Lucena e mais 2Arquivos Brasileiros de Oftalmologia2013

    PURPOSE: The aim of this study was to verify the presence of cyclotorsion in eyes that underwent laser refractive surgery. METHODS: This was a comparative observational study, which analyzed the medical records of 61 patients (104 eyes) who underwent laser refractive surgery and compared the axis of astigmatism of the…

  7. Wavefront-guided refractive surgery results of training-surgeons

    Iane Stillitano, Ester Yamazaki, Luiz Alberto Melo Jr e mais 2Arquivos Brasileiros de Oftalmologia2010

    PURPOSE: To assess clinical outcomes and changes on higher-order aberrations (HOA) after wavefront-guided laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) for correction of myopia and myopic astigmatism performed by training-surgeons. METHODS: One hundred and seventy patients had customized…

  8. Intrastromal corneal ring segment implantation for ectasia after refractive surgery

    Larissa Rossana Souza Stival, Belquiz R. do Amaral Nassaralla, Marisa Novaes Falleiro Chaves de Figueiredo e mais 2Arquivos Brasileiros de Oftalmologia2015

    ABSTRACTPurpose:To evaluate the clinical outcomes of intrastromal corneal ring segment (ICRS) implantation to correct ectasia in eyes with prior refractive surgery.Methods:Forty-one eyes of 25 patients (13 men, 12 women; mean age, 28.66 years) with ectasia after refractive surgery [photorefractive keratectomy (PRK) or…

  9. Reliability of a Scheimpflug-based tomographer compared with a Placido-based topographer and specular microscopy in healthy eyes

    Camyla Lemos Budib, Caio Henrique Peres Oliani, Guilherme de Oliveira Ferreira e mais 6Arquivos Brasileiros de Oftalmologia2026citado por 1 artigo

    ABSTRACT Purpose: To evaluate the reliability and comparability of a Scheimpflug-based tomographer relative to a Placido-based topographer and specular microscopy in healthy eyes. Methods: This cross-sectional study included 40 patients (80 eyes). Each eye underwent randomized imaging with a Scheimpflug-based…

  10. Keratoconus false-positive screening rates in eyes with pterygium: tomographic and biomechanical artifacts

    Pablo Felipe Rodrigues, Felipe A. Casseb dos Santos, Bernardo Kaplan Moscovici e mais 3Arquivos Brasileiros de Oftalmologia2026

    ABSTRACT Purpose: To investigate tomographic and biomechanical screening artifacts associated with primary pterygium that may mimic keratoconus-like patterns before and after surgical excision. Methods: Twenty-five eyes with primary pterygium underwent Scheimpflug corneal tomography and dynamic corneal response…

  11. Clinical experience with adjustable scleral lenses

    César Lipener e Juliana RosaArquivos Brasileiros de Oftalmologia2023citado por 1 artigo

    ABSTRACT Purpose: The aim of this study was to evaluate the fitting process of a scleral lens that allows several parameter adjustments during trials and after the initial period of use. In addition, we verified which adjustments were needed and used the most, their indications, and how often these resources were…

  12. Unexpectedly high corneal flap thickness and ectasia after mechanical LASIK

    José Belucio Neto, João Carlos Gonçalves Cruz, Celso Busnelo Moreno e mais 1Revista Brasileira de Oftalmologia2023

    ABSTRACT LASIK is a refractive surgical procedure in which a corneal flap is created to expose the corneal stromal bed. Preoperative estimation of corneal flap thickness is necessary to calculate the percentage tissue altered in LASIK, an important quantitative risk factor for ectasia. The objective of this study was…

  13. Vitamin A and the eye: an old tale for modern times

    Jacqueline Ferreira Faustino, Alfredo Ribeiro-Silva, Rodrigo Faeda Dalto e mais 5Arquivos Brasileiros de Oftalmologia2016citado por 1 artigo

    ABSTRACT Clinical presentations associated with vitamin A deficiency persist in poor regions globally with the same clinical features as those described centuries ago. However, new forms of vitamin A deficiency affecting the eyes, which have become widespread, as a result of modern societal habits are of increasing…

  14. Clinical experience with the first 40 cases with femtosecond laser cataract surgery technology: safety of the learning curve

    Joao Crispim, Ricardo Nose, Ana Claudia Medeiros A. Garcia e mais 2Revista Brasileira de Oftalmologia2015citado por 1 artigo

    ABSTRACT Objective: To evaluate the introduction of the femtosecond laser (FSL) to perform the key steps of the traditional cataract surgery process and the operational difficulties and safety of this new technology during routine use in an operating room in Brazil. Methods A retrospective study was conducted using…

  15. Intrastromal crosslinking in post-LASIK ectasia

    Bernardo Kaplan Moscovici e Mauro CamposArquivos Brasileiros de Oftalmologia2014

    We describe a case of early post-LASIK ectasia detected in the first 6 months after surgery. The patient was treated by means of intrastromal corneal crosslinking under the flap, without de-epithelialization, which resulted in a positive outcome. At the time of writing, 2 years after the procedure, the patient…

  16. ORA waveform-derived biomechanical parameters to distinguish normal from keratoconic eyes

    Allan Luz, Bruno Machado Fontes, Bernardo Lopes e mais 3Arquivos Brasileiros de Oftalmologia2013citado por 1 artigo

    PURPOSE: To evaluate the ability of the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) to distinguish between normal and keratoconic eyes, by comparing pressure and waveform signal-derived parameters. METHODS: This retrospective comparative case series study included 112 patients with…

  17. Interchangeability between Placido disc and Scheimpflug system: quantitative and qualitative analysis

    Vinícius Silbiger de Stefano, Luiz Alberto Soares Melo Junior, Felipe Mallmann e mais 1Arquivos Brasileiros de Oftalmologia2010

    PURPOSE: Many systems try to replace Placido disc-based topographers, such as those based in Scheimpflug principles. The purpose of this study is to check if they are interchangeable. METHODS: Quantitative analysis evaluated data obtained from EyeSys and Pentacam, i.e. simulated keratometric values, in addition to…

  18. Proposal for a new approach to corneal biomechanics: dynamic corneal opography

    José Américo Bonatti, Samir Jacob Bechara, Pedro Carlos Carricondo e mais 1Arquivos Brasileiros de Oftalmologia2009

    PURPOSE: To establish the literature basis that could support the idea that it would be possible to analyze changes at the anterior surface of the cornea induced by an air jet applied onto the eye. METHODS: The PUBMED/MEDLINE literature basis regarding the following subjects was searched: videokeratography, high-speed…