acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Optometry”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Corneal sensitivity recovery after phacoemulsification: quantitative esthesiometric analysis

    Isabella Passarelli Giabardo Marques, Christiana Velloso Rebello Hilgert, Caio Henrique Peres Oliani e mais 4Arquivos Brasileiros de Oftalmologia2026

    ABSTRACT Purpose: To quantitatively assess changes in central corneal sensitivity after phacoemulsification and to characterize recovery patterns up to 90 days using standardized esthesiometry. Methods: This prospective observational study included 44 patients (88 eyes) undergoing uncomplicated phacoemulsification…

  2. Effect of superior blepharoplasty on tear film: objective evaluation with the Keratograph 5M - a pilot study

    Andreia Soares, Fernando Faria-Correia, Nuno Franqueira e mais 1Arquivos Brasileiros de Oftalmologia2018citado por 1 artigo

    ABSTRACT Purpose: To evaluate the effect of superior blepharoplasty on the tear film using the corneal topographer Keratograph 5M. Methods: A prospective study was performed of 27 eyes of 14 patients with superior dermatochalasis who underwent superior blepharoplasty between May and June 2016. Conservative upper…

  3. Asthenopic symptoms prevalence in undergraduate students

    Flávio Marconiedson Nunes, Henrique Nunes Pereira Oliva, Gabriella de Sá Oliveira e mais 1Revista Brasileira de Oftalmologia2018citado por 1 artigo

    Abstract Objective: To analyze the prevalence of asthenic symptoms in students of higher education and to assess their influence on academic performance and learning. Methods: Descriptive research with cross-sectional design through the application of the College of Optometrists Questionnaire in Vision Development…

  4. Interchangeability between Placido disc and Scheimpflug system: quantitative and qualitative analysis

    Vinícius Silbiger de Stefano, Luiz Alberto Soares Melo Junior, Felipe Mallmann e mais 1Arquivos Brasileiros de Oftalmologia2010

    PURPOSE: Many systems try to replace Placido disc-based topographers, such as those based in Scheimpflug principles. The purpose of this study is to check if they are interchangeable. METHODS: Quantitative analysis evaluated data obtained from EyeSys and Pentacam, i.e. simulated keratometric values, in addition to…

  5. Preliminary results of a high-resolution refractometer using the Hartmann-Shack wave-front sensor: part I

    Luis Alberto Carvalho, Antonio Carlos Romao, Marcos Stefani e mais 7Arquivos Brasileiros de Oftalmologia2003

    In this project we are developing an instrument for measuring the wave-front aberrations of the human eye using the Hartmann-Shack sensor. A laser source is directed towards the eye and its diffuse reflection at the retina generates an approximately spherical wave-front inside the eye. This wave-front travels through…