acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “multivariate calibration”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Multivariate calibration transfer employing variable selection and subagging

    Marcelo N. Martins, Roberto K. H. Galvão e Maria Fernanda PimentelJournal of the Brazilian Chemical Society2010

    This paper proposes a new technique for calibration transfer, which combines the Successive Projections Algorithm (SPA) for robust variable selection with the subsampling and model aggregation technique known as subagging. The proposed technique is aimed at building Multiple Linear Regression (MLR) models that are…

  2. Simultaneous spectrophotometric determination and classical least squares method: a simple experiment to introduce the concept of multivariate calibration

    Jhonatas R. Carvalho, Larissa R. Lopes, Luciano N. Vidal e mais 1Química Nova2021

    We herein present an experiment where the concentrations of tartrazine, sunset yellow and amaranth in samples containing these three food dyes are determined by system of equations (SE) and classical least squares (CLS) multivariate calibration methods using light absorption data. Firstly, concentrations are obtained…

  3. Spectrophotometric determination of phenol in the presence of congeners by multivariated calibration

    KELY VIVIANE DE SOUZA e PATRICIO PERALTA-ZAMORAAnais da Academia Brasileira de Ciências2001

    The generation of poly-hydroxilated transient species during the photochemical treatment of phenol usually impedes the spectrophotmetric monitoring of its degradation process. Frequently, the appearance of compounds such as pyrocatechol, hydroquinone and benzoquinone produces serious spectral interference, which…

  4. Simultaneous spectrophotometric determination of lamivudine and zidovudine in fixed dose combinations using multivariate calibration

    Severino Grangeiro Jr., Miracy M. Albuquerque, Davi P. Santana e mais 3Química Nova2011

    The simultaneous determination of two or more active components in pharmaceutical preparations, without previous chemical separation, is a common analytical problem. Published works describe the determination of AZT and 3TC separately, as raw material or in different pharmaceutical preparations. In this work, a method…

  5. Effect of the subsampling ratio in the application of subagging for multivariate calibration with the successive projections algorithm

    Arlindo R. Galvão Filho, Roberto K. H. Galvão e Mário César U. AraújoJournal of the Brazilian Chemical Society2011

    This paper concerns the effect of the subsampling ratio on the subagging approach for multiple linear regression with variable selection by the successive projections algorithm. Investigations involving simulated data, as well as near-infrared spectrometric determination of moisture and protein in wheat and…

  6. Simultaneous voltammetric determination of dypirone and paracetamol with carbon paste electrode and multivariate calibration methodology

    Tatiane Skeika, Mariane Ferreira de Faria, Noemi Nagata e mais 1Journal of the Brazilian Chemical Society2008citado por 1 artigo

    This paper shows the simultaneous electrochemical determination of dypirone (DIP) and paracetamol (PAR) by differential pulse voltammetry technique (DPV) using an unmodified carbon paste electrode. Because of the overlapping of the voltammetric peaks of DIP and PAR, the multivariate calibration methodology based on…

  7. Development and validation of a multivariate calibration model for determination of dipyrone in oral solutions by near infrared spectroscopy

    Marcus H. Ferreira, Jorge F. F. Gomes e Marcelo M. SenaJournal of the Brazilian Chemical Society2009

    This work developed a new method for determination of dipyrone (DIP) in oral pharmaceutical formulations, through the use of near infrared (NIR) transflectance measurements and multivariate calibration. The studied range varied from 300.0 to 569.2 mg mL-1. The best PLS (partial least squares) model was obtained with…

  8. Validation of multivariate calibration models in the determination of sugar cane quality parameters by near infrared spectroscopy

    Patrícia Valderrama, Jez W. B. Braga e Ronei J. PoppiJournal of the Brazilian Chemical Society2007citado por 3 artigos

    The determination of soluble solids (BRIX), polarizable sugars (POL) and reducing sugars (RS) sugar cane juice by using near infrared spectroscopy (NIR) and multivariate calibration was developed and validated by calculation of figures of merit. Due to the heterogeneity of the samples, first it was necessary to…

  9. Multivariate Calibration to Determine Phorbol Esters in Seeds of Jatropha curcas L. Using Near Infrared and Ultraviolet Spectroscopies

    Jussara V. Roque, Luiz A. S. Dias e Reinaldo F. TeófiloJournal of the Brazilian Chemical Society2017citado por 1 artigo

    The building of partial least squares (PLS) regression models using near infrared (NIR) and ultraviolet (UV) spectroscopies to estimate the concentrations of phorbol esters (PEs) in Jatropha curcas L. is presented. The models were built using two algorithms for variable selection, ordered predictors selection (OPS)…

  10. Use of an Automatic System in the Preparation of Gas Mixtures for Multivariate Calibration: A Case Study Involving NIR Analysis of Natural Gas

    Barbosa Barbosa, Hebertty V. Dantas, Pablo N. T. Moreira e mais 2Journal of the Brazilian Chemical Society2015

    This paper investigates the use of an automatic system for preparation of gas mixtures in a multivariate calibration problem involving near-infrared (NIR) spectrometric analysis of natural gas. The automatic system is used to prepare calibration mixtures according to a Brereton experimental design, in order to exploit…

  11. Simultaneous voltammetric determination of dopamine and ascorbic acid using multivariate calibration methodology performed on a carbon paste electrode modified by a mer-[RuCl3(dppb)(4-pic)] complex

    Poliana M. Santos, Bianca Sandrino, Tiago F. Moreira e mais 3Journal of the Brazilian Chemical Society2007

    The preparation and electrochemical characterization of a carbon paste electrode (CPE) modified with mer-[Ru0Cl3(dppb)(4-pic)] (dppb=Ph2P(CH2)4PPh2, 4-pic=CH3C5H4N), referred to as Rupic, were investigated. The CPE/Rupic system displayed only one pair of redox peaks, with a midpoint potential at 0.28 V vs. Ag/AgCl…

  12. Modified hybrid particle swarm optimization: multivariate calibration of water supply networks

    Hugo Augusto Marinho Moreira, Juan Moises Mauricio Villanueva e Heber Pimentel GomesRBRH2025

    Abstract Calibration is essential to ensure the accuracy of hydraulic models, adjusting hydraulic parameters to reliably represent real systems. This work presents the implementation of the Modified Hybrid Particle Swarm Optimization with ‘fmincon’ (PSO-HM) evolutionary search method to propose efficient and robust…

  13. UV determination of epinephrine, uric acid, and acetaminophen in pharmaceutical formulations and some human body fluids using multivariate calibration

    Hanieh Montaseri, Habibollah Khajehsharifi e Saeed YousefinejadQuímica Nova2014

    In this work, a spectrophotometric methodology was applied in order to determine epinephrine (EP), uric acid (UA), and acetaminophen (AC) in pharmaceutical formulations and spiked human serum, plasma, and urine by using a multivariate approach. Multivariate calibration methods such as partial least squares (PLS)…

  14. Prediction of Sulfur Content in Diesel/Biodiesel Blends Using LED-Induced Fluorescence Associated with Multivariate Calibration

    Alessandra T. Campos, Cristina M. Quintella, Marilena Meira e mais 1Journal of the Brazilian Chemical Society2018

    The present paper concerns to predict the sulfur concentration in biodiesel/diesel blends in the range of 5-100 mg L-1 of sulfur using spectrofluorimetry and partial least squares multivariate calibration (PLS). The calibration set consisted of samples with 10 and 20% (B10 and B20) of biodiesel in diesel with sulfur…

  15. Comparison between Ultraviolet and Infrared Spectroscopies for the Simultaneous Multivariate Determination of Pyrantel and Praziquantel

    Mário S. Piantavini, Flávia L. D. Pontes, Leandro X. Weiss e mais 2Journal of the Brazilian Chemical Society2015

    Methods based on multivariate calibration and diffuse reflectance infrared Fourier transform (DRIFT) and ultraviolet (UV) spectroscopies were developed for the simultaneous determination of two veterinary pharmaceutical drugs, pyrantel pamoate and praziquantel, in commercial tablets. The best UV model was obtained…

  16. Multivariate spectroscopic determination of the lamivudine-zidovudine association

    Gilcélia A Cordeiro, Noemi Nagata, Iara Messerschmidt e mais 2Journal of the Brazilian Chemical Society2011

    The multivariate spectroscopic determination of lamivudine-zidovudine associations was carried out by partial least square regression (PLS). This model was developed from 20 synthetic mixtures using mean-centered spectral data acquired from 190 to 350 nm and with 3 latent variables. External validation was performed…

  17. VIS-NIR portable espectrometer for non-destructive assessment of maturity and quality of ‘Gala’ apples

    Jádina Cristina Vaz Moraes Bellotto, William Coser, Cassandro Vidal Talamini do Amarante e mais 3Revista Brasileira de Fruticultura2023

    Abstract Visible and near infrared (VIS-NIR) spectroscopy is a non-destructive, fast, practical and reliable technique to determine maturity and quality attributes in apple fruit. However, the effects of cultivar and growing conditions on the predictive performance of the equipment must be determined before its…

  18. A Mid-Infrared Spectrophotometric Method for Simultaneous Quantification of Naltrexone and Bupropion with Multivariate Calibration

    Andrea Cristina Novack, Alexandre F. Cobre, Camila Regina S. Madeira e mais 4Journal of the Brazilian Chemical Society2023

    Naltrexone (NTX) and bupropion (BUP) are used in combination in clinical practice for obesity; however, the existing analytical methods for this drug combination are not sustainable. This work aims to develop an analytical method that is faster, easier and less expensive compared with high performance liquid…

  19. AVANÇOS ANALÍTICOS BASEADOS EM MODELOS DE CALIBRAÇÃO DE PRIMEIRA ORDEM E ESPECTROSCOPIA UV-VIS PARA AVALIAÇÃO DA QUALIDADE DA ÁGUA: UMA REVISÃO - PARTE 1

    Grazielle R. Santos, Gabriela S. P. Paulino, Grazielle P. I. Borges e mais 2Química Nova2022

    This work aimed to infer about the scientific progress of the use of ultraviolet-visible (UV-Vis) spectrophotometry for evaluations of water quality. The research started in the 60s, when the imminence of obtaining characteristics of the UV-Vis spectrum that estimated the water quality. From a temporal perspective…

  20. Quantification of Carbon Dioxide (CO2), Methane (CH4), and Nitrous Oxide (N2O) Using Near Infrared Spectroscopy and Multivariate Calibration in High Humidity Levels

    Rafael L. Ribessi, Wilson F. Jardim, Jarbas J. R. Rohwedder e mais 1Journal of the Brazilian Chemical Society2022

    In this work we developed a promising analytical method combining Fourier transform near-infrared (FT-NIR) spectroscopic technique and first-order multivariate calibration using partial least-squares (PLS) model to simultaneously quantify the main greenhouse gases (GHG’s): methane (CH4), carbon dioxide (CO2), nitrous…