Journal of the Brazilian Chemical Society2009

Development and validation of a multivariate calibration model for determination of dipyrone in oral solutions by near infrared spectroscopy

Marcus H. Ferreira, Jorge F. F. Gomes e Marcelo M. Sena

em inglês

cita 8 obras

resumo

This work developed a new method for determination of dipyrone (DIP) in oral pharmaceutical formulations, through the use of near infrared (NIR) transflectance measurements and multivariate calibration. The studied range varied from 300.0 to 569.2 mg mL-1. The best PLS (partial least squares) model was obtained with two latent variables and the root mean square errors of calibration and prediction were 1.1 and 1.0 mg mL-1, respectively. The proposed method was validated in accordance with ANVISA, the Brazilian regulatory agency, and ICH, being considered selective, linear, precise, accurate and robust. By comparison with the main alternatives, iodimetric titration and HPLC, this method is simpler, non-destructive, does not use reagents or solvents and does not produce chemical waste. Besides, its rapidity is considered the major advantage over the other methods, since only about 50 s were spent per assay.

como citar · ABNT NBR 6023

FERREIRA, Marcus H.; GOMES, Jorge F. F.; SENA, Marcelo M. Development and validation of a multivariate calibration model for determination of dipyrone in oral solutions by near infrared spectroscopy. Journal of the Brazilian Chemical Society, 2009. DOI: 10.1590/S0103-50532009000900017.

Referências

8 obras citadas

  1. 3Farmacopéia Brasileira. 2002quem mais cita →
  2. 4European Pharmacopoeia. 2002quem mais cita →
  3. 19D. A. Burns e E. W. Ciurczak. Handbook of Near-Infrared Analysis. 2001quem mais cita →
  4. 25Agência Nacional de Vigilância Sanitária. Guia para Validação de Métodos Analíticos e Bioanalíticos. 2003quem mais cita →
  5. 26International Conference on Harmonization. Tripartite Guideline-Q2A Text on Validation of Analytical Procedures. 1995quem mais cita →
  6. 27International Conference on Harmonization. Tripartite Guideline-Q2B Validation of Analytical Procedures: Methodology. 1997quem mais cita →
  7. 30Annual Book of ASTM Standards. Standard Practices for Infrared Multivariate Quantitative Analysis-E1655-00. 2000quem mais cita →
  8. 33N. Broad, P. Graham, P. Hailey e mais 7. Handbook of Vibrational Spectroscopy. 2002quem mais cita →