acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “biomechanical phenomena”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. FUNCTIONAL TESTS AND ISOKINETIC KNEE ASSESSMENT IN STREET RUNNER ATHLETES CORRELATION

    João Pedro Borges, Danilo Teixeira de Barros Duarte, Marcelo Camargo Saad e mais 1Revista Brasileira de Medicina do Esporte2024

    ABSTRACT Introduction: The assessment of biomechanical changes related to the lower limbs is necessary in clinical practice to measure the potential risks of injury and the influences on existing dysfunction. Biomechanical changes related to previous ankle injuries are known to influence the performance of the entire…

  2. BIOMECHANICAL ENERGY METABOLISM MODEL OF SPORTS MEDICINE

    Lu JinRevista Brasileira de Medicina do Esporte2021

    ABSTRACT Introduction: This is a study on the reasonable organization and collocation of sports health elements in different sports forms, and how this is reflected through scientific exercise instructors. Objective: To improve the effect of sports medicine on the biomechanical energy metabolism of human health…

  3. Is there a Difference in Interfragmentary Compression Strength Between Fully or Partially Threaded Screws? Results of an Experimental Biomechanical Pilot Study

    Tosan Okoro, Marcus Landgren, Edem Afenu e mais 3Revista Brasileira de Ortopedia2023

    Abstract Objective This study assessed differences between fully- and partially-threaded screws in the initial interfragmentary compression strength. Our hypothesis was that there would be an increased loss in initial compression strength with the partially-threaded screw. Methods A 45-degree oblique fracture line was…

  4. Are Anterior Plates More Effective than Iliosacral Screws to Fix the Sacroiliac Joint? Biomechanical Study

    Flavio Goldsztajn, Jose Ricardo L. Mariolani e William Dias BelangeroRevista Brasileira de Ortopedia2020

    Abstract Introduction Sacroiliac joint dislocations are caused by high energy trauma and commonly treated with the iliosacral screw fixation or the anterior plating of the sacroiliac joint (SIJ). However, there is a lack of consensus regarding which procedure is the most successful in treating sacroiliac joint…

  5. Keratoconus false-positive screening rates in eyes with pterygium: tomographic and biomechanical artifacts

    Pablo Felipe Rodrigues, Felipe A. Casseb dos Santos, Bernardo Kaplan Moscovici e mais 3Arquivos Brasileiros de Oftalmologia2026

    ABSTRACT Purpose: To investigate tomographic and biomechanical screening artifacts associated with primary pterygium that may mimic keratoconus-like patterns before and after surgical excision. Methods: Twenty-five eyes with primary pterygium underwent Scheimpflug corneal tomography and dynamic corneal response…

  6. FIXATION METHODS IN LATARJET: BIOMECHANICAL COMPARISON OF SCREW TYPES AND PLATE FIXATION

    UFUK ARZU, MEHMET ERSIN, MEHMET CHODZA e mais 3Acta Ortopédica Brasileira2023

    ABSTRACT Objective Latarjet procedure is often preferred in recurrent shoulder dislocations accompanied by glenoid bone loss. It is observed that the superiority of bone graft fixation methods is still controversial. The aim of this study is to biomechanically compare the bone graft fixation methods in the Latarjet…

  7. Thick Graft Versus Double-Bundle Technique on Posterior Cruciate Ligament Reconstruction: Experimental Biomechanical Study with Cadavers

    João Alberto Ramos Maradei-Pereira, Alexandre Estevão Vamos Kokron, César Augusto Martins Pereira e mais 1Revista Brasileira de Ortopedia2019

    Abstract Objective To evaluate the biomechanical effect of graft thickness compared with the double-bundle technique on posterior cruciate ligament (PCL) reconstruction in human cadaveric knees. Methods A total of 9 human cadaveric knees were tested in 5 conditions: intact knee (INT); single-bundle reconstruction with…

  8. Lower Limb Biomechanical Variables Are Indicators of the Pattern of Presentation of Patella Tendinopathy in Elite African Basketball and Volleyball Players

    Ayoola Aiyegbusi, Bidemi Tella e Chukwuebuka OkekeRevista Brasileira de Ortopedia2019

    Abstract Objective The present study determined the pattern of presentation and severity of patellar tendinopathy (PT) and its relationship with selected biomechanical variables in elite athletes. Methods The study involved 98 elite Nigerian basketball and volleyball players aged between 18 and 35 years. Clinical…

  9. Biomechanical Gait Analysis in Patients with Osteonecrosis of the Femoral Head

    Julia Silva e Lima Schleder, Danielly Caroline de Souza Ramello, Mauro Duarte Caron e mais 1Revista Brasileira de Ortopedia2023

    Abstract Objectives Although osteonecrosis of the femoral head is a prevalent condition, its effects on gait parameters have not been thoroughly studied and are not well-established in the current literature. The primary aim of the present study is to describe gait in patients with a diagnosis of osteonecrosis…

  10. Biomechanical Analysis of Two Types of Humerus Supracondylar Fracture Fixation in Anatomical Model

    Marcos Ceita Nunes, Ticiano Dozza Posser, Charles Leonardo Israel e mais 3Revista Brasileira de Ortopedia2019

    Abstract Objective To analyze the stability of humerus supracondylar fracture fixation with Kirschner wires comparing intramedullary and lateral (Fi), and two parallel lateral wires (FL) fixation in experimental models, to define which configuration presents greater stability. Methods A total of 72 synthetic humeri…

  11. Effect of corneal biomechanical properties on surgically-induced astigmatism and higher-order aberrations after cataract surgery

    Mustafa Koç, Çağrı İlhan, Yaran Koban e mais 3Arquivos Brasileiros de Oftalmologia2016

    ABSTRACT Purpose: To investigate the relationship between biomechanical properties of the cornea and postoperative refractive changes in patients with low-level astigmatism after cataract surgery. Methods: This prospective study recruited patients undergoing cataract surgery involving 2.8-mm superior incisions…

  12. Proximal Biceps Tenodesis – Biomechanical Analysis in Sheep: Comparison between Metallic Anchor, Onlay Bioabsorbable Knotless Anchor, and Interference Screw

    Amauri João Orso Júnior, Mateus Franceschi Dallanora, Paulo Cesar Faiad Piluski e mais 3Revista Brasileira de Ortopedia2024

    Abstract Objective To biomechanically evaluate different fixation devices for the proximal biceps in the humerus of sheep, comparing their fixation strength to failure, tendon displacement, and failure site in each technique. Methods A total of 27 humerus tests were performed on sheep, separating them into 3 groups…

  13. Biomechanical Study of Different Femoral Fixation Devices in the Reconstruction of the Medial Patellofemoral Ligament in Porcine Knees

    Lothar Schmechel Dobke, João Artur Bonadiman, Osmar Valadão Lopes Jr e mais 3Revista Brasileira de Ortopedia2020

    Abstract Objective To evaluate different femoral fixation devices for medial patellofemoral ligament reconstruction and compare their effectiveness regarding fixation strength up to failure in porcine knees. Methods Thirty porcine knees were used, divided into three groups of 10 knees. The removed grafts were…

  14. RADIOGRAPHIC UNION OVERESTIMATES BIOMECHANICAL STRENGTH: A CEILING EFFECT OF THE RUST SCORE IN RAT TIBIA MODELS

    Ana Letícia Pagotti Rubello, Ricardo Martins-Santos, Iverson Silva Correia e mais 4Acta Ortopédica Brasileira2026

    ABSTRACT Objective: To evaluate if the Radiographic Union Scale for Tibial Fractures (RUST) identifies bone consolidation in rat tibia osteotomies, correlating it with biomechanical parameters. Methods: Forty-five Wistar rats underwent right proximal tibia osteotomies, fixed with 0.8mm Kirschner wires. At 8 weeks…

  15. Biomechanical and morphological changes produced by ionizing radiation on bone tissue surrounding dental implant

    Priscilla Barbosa Ferreira Soares, Carlos José Soares, Pedro Henrique Justino Oliveira Limirio e mais 3Journal of Applied Oral Science2020citado por 1 artigo

    Abstract Objective: This study analyzed the effect of ionizing radiation on bone microarchitecture and biomechanical properties in the bone tissue surrounding a dental implant. Methodology: Twenty rabbits received three dental morse taper junction implants: one in the left tibia and two in the right tibia. The animals…

  16. Biomechanical evaluation in runners with Achilles tendinopathy

    Nathalie Ferrari Bechara Andere, Alexandre Leme Godoy-Santos, Luis Mochizuki e mais 7Clinics2021citado por 1 artigo

    OBJECTIVES: To evaluate the clinical characteristics, ground reaction force (GRF), and function of the plantar muscles and dorsiflexors of the ankle in runners with and without Achilles tendinopathy (AT) and in non-runners. METHODS: Seventy-two participants (42 men, 30 women; mean age: 37.3±9.9 years) were enrolled in…

  17. Cross-sectional Evaluation of the Mechanical Axis and Other Angular Parameters of the Lower Limbs in Male Professional Soccer Players

    Jean Klay Santos Machado, Eurineto Gomes do Nascimento e Erik Silva de MenezesRevista Brasileira de Ortopedia2026

    Abstract Objective To evaluate themechanical axis and angular parameters of the lower limbs in professional soccer players, relating themto age, limb dominance, and field position. Methods The present cross-sectional study included 102 male athletes from a Brazilian professional soccer team. Full-length radiographs in…

  18. VALIDATION OF AN OPTICAL METHOD FOR MEASURING THE GAP BETWEEN SUTURED TENDON STUMPS

    Luiz Sorrenti, Elcio Koodiro Yoshida, Antonio Isidoro de Sousa Neto e mais 3Acta Ortopédica Brasileira2026

    ABSTRACT Objective: This study aims to investigate the accuracy and precision of an optical measurement method based on backlight video analysis for measuring gap distances between tendon stumps in a rigid tendon model. Methods: A rigid 3D-printed tendon model was sutured and subjected to traction using a universal…

  19. Short-term orthokeratology effects on corneal biomechanics with a focus on SPA1 and stress-strain index (SSI) parameters in pediatric myopia

    Wenjuan Xie, Xue Li, Cheng Yang e mais 5Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: Although the orthokeratology effects on corneal biomechanics have been proven with clinical trials, reports of stiffness parameter change are scarce. This study investigated the short-term orthokeratology effects in pediatric myopia and compared stiffness parameter changes to those published in…

  20. Impact of radiotherapy in chemical composition and mechanical properties of human cervical dentin: an in vitro study

    Renata Borges RODRIGUES, Allyne Jorcelino Daloia de CARVALHO, Bruna Vanessa FELIPE E SILVA e mais 2Journal of Applied Oral Science2025

    Abstract Ionizing radiation directly affects hard dental tissues, compromising the dental structure, which results in damage to dentin collagen fibers and impacts the integrity of the dentin-enamel junction (DEJ). Objective To evaluate the effects of radiotherapy on the chemical composition and mechanical properties…