Abstract Objective This study assessed differences between fully- and partially-threaded screws in the initial interfragmentary compression strength. Our hypothesis was that there would be an increased loss in initial compression strength with the partially-threaded screw. Methods A 45-degree oblique fracture line was created in artificial bone samples. The first group (FULL, n = 6) was fixed using a 3.5-mm fully-threaded lag screw, while the second group (PARTIAL, n = 6) used a 3.5-mm partially-threaded lag screw. Torsional stiffness for both rotational directions were evaluated. The groups were compared based on biomechanical parameters: angle-moment-stiffness, time-moment-stiffness, maximal torsional moment (failure load), and calibrated compression force based on pressure sensor measurement. Results After loss of one PARTIAL sample, no statistically significant differences in calibrated compression force measurement were observed between both groups: [median (interquartile range)] FULL: 112.6 (10.5) N versus PARTIAL: 106.9 (7.1) N, Mann-Whitney U-test: p = 0.8). In addition, after exclusion of 3 samples for mechanical testing (FULL n = 5, PARTIAL n = 4), no statistically significant differences were observed between FULL and PARTIAL constructs in angle-moment-stiffness, time-moment-stiffness, nor maximum torsional moment (failure load). Conclusion There is no apparent difference in the initial compression strength (compression force or construct stiffness or failure load) achieved using either fully-or partially-threaded screws in this biomechanical model in high-density artificial bone. Fully-threaded screws could, therefore, be more useful in diaphyseal fracture treatment. Further research on the impact in softer osteoporotic, or metaphyseal bone models, and to evaluate the clinical significance is required.

como citar · ABNT NBR 6023

OKORO, Tosan et al. Is there a Difference in Interfragmentary Compression Strength Between Fully or Partially Threaded Screws? Results of an Experimental Biomechanical Pilot Study. Revista Brasileira de Ortopedia, 2023. DOI: 10.1055/S-0042-1750828.

Referências

24 obras citadas

  1. 1TT Roberts, CM Prummer, DN Papaliodis e mais 2. History of the orthopedic screw. Orthopedics, 2013quem mais cita →
  2. 2MW Downey, V Kosmopoulos e BB Carpenter. Fully Threaded Versus Partially Threaded Screws: Determining Shear in Cancellous Bone Fixation. J Foot Ankle Surg, 2015quem mais cita →
  3. 3AP Singh. Interfragmentary Screw or Lag Screw Fixationquem mais cita →
  4. 4J Eastman, B Deafenbaugh, B Christiansen e mais 2. Achieving interfragmentary compression without special drilling technique or screw design. J Orthop Res, 2018quem mais cita →
  5. 5E Rao, S Naveen, RC Rao e mais 3. Principle of Lag-Screw Fixation in Mandibular Trauma. J Int Soc Prev Community Dent, 2019quem mais cita →
  6. 6JB Giles, JC DeLee, JD Heckman e mais 1. Supracondylar-intercondylar fractures of the femur treated with a supracondylar plate and lag screw. J Bone Joint Surg Am, 1982quem mais cita →
  7. 7SJ Vijimohan, S Haque e D Ellis. An Alternate Technique of Applying Lag Screw for Fixation of Distal Fibula Fracture: Posterior to Anterior Interfragmentary Compression Screw. Foot Ankle Spec, 2017quem mais cita →
  8. 8GA Mencio, MF Swiontkowski e NE Green. Green’s skeletal trauma in children. 2015quem mais cita →
  9. 9M Greiwe. Shoulder and elbow trauma and its complications. Volume 2: The elbow. 2015quem mais cita →
  10. 10NP Sheth e JH Lonner. Gowned and Gloved Orthopaedics: Introduction to Common Procedures. 2009quem mais cita →
  11. 11F Miyanji, A Mahar, R Oka e mais 2. Biomechanical comparison of fully and partially threaded screws for fixation of slipped capital femoral epiphysis. J Pediatr Orthop, 2008quem mais cita →
  12. 12T Bulut, M Gursoy e H Ertem. Fully threaded headless compression screw versus partially threaded cancellous lag screw in medial malleolus fractures: clinical and radiological outcomes. Eur J Trauma Emerg Surg, 2021quem mais cita →
  13. 13JP Kassi, JE Hoffmann, M Heller e mais 2. Bewertung der Stabilität von Frakturfixationssystemen: Mechanische Vorrichtung zur Untersuchung der 3-D-Steifigkeit in vitro. Biomed Tech (Berl), 2001quem mais cita →
  14. 14G Duda. Muskuloskelettale Belastungen: Beitrag zu den mechanischen Rahmenbedingungen der Frakturheilung. 2001quem mais cita →
  15. 15S Crosbie e D Corliss. Are you dense? using kernel density estimation (kde) to connect the dots amidst uncertainty (Paper DV-06– 2012). 2012quem mais cita →
  16. 16JC Rozell, M Chin, DJ Donegan e mais 1. Biomechanical Comparison of Fully Threaded Solid Cortical Versus Partially Threaded Cannulated Cancellous Screw Fixation for Lisfranc Injuries. Orthopedics, 2018quem mais cita →
  17. 17A Salduz, F Birisik, G Polat e mais 3. The effect of screw thread length on initial stability of Schatzker type 1 tibial plateau fracture fixation: a biomechanical study. J Orthop Surg Res, 2016quem mais cita →
  18. 18E Keltz, AJ Mora e D Wulsten. Is initial interfragmentary compression made to last? An ovine bone in vitro study. Injury, 2021quem mais cita →
  19. 19A Hart, EJ Harvey, R Rabiei e mais 2. Fixation strength of four headless compression screws. Med Eng Phys, 2016quem mais cita →
  20. 20MR Miles, T Green, BG Parks e mais 3. Comparison of Lag Versus Nonlag Screw Fixation for Long Oblique Proximal Phalanx Fractures: A Biomechanical Study. J Hand Surg Am, 2021quem mais cita →
1–20 de 24 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações