acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “automation laboratory”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Harmonization study of results between biochemical analyzers Labmax 240® and Labmax 240 Premium®

    Luisa D. Scapin, Vanessa P. Ramos, Marion de Marco e mais 2Jornal Brasileiro de Patologia e Medicina Laboratorial2018

    ABSTRACT Introduction: The harmonization of equipment is recommended in clinical laboratory practice aiming for the homogeneity of results when similar or equivalent analyzers are used to perform routine testing. Objectives: To conduct a study of equivalence between the biochemical analyzers Labmax 240® (E1) and…

  2. Pseudothrombocytopenia: incidence and strategy for resolution in clinical laboratory

    Romário F. Prates, Robson C. Viana, Márcio V. Oliveira e mais 1Jornal Brasileiro de Patologia e Medicina Laboratorial2017

    ABSTRACT Introduction: Pseudothrombocytopenia is an important source of pre-analytical problems in clinical laboratory; therefore it must be correctly evaluated. Low spurious platelet counts can lead to misdiagnosis. Objective: This study aims to study the resolution of pseudothrombocytopenia in the laboratory routine…

  3. Validation of the Sysmex sp-1000i automated slide preparer-stainer in a clinical laboratory

    Eberson Damiao dos Santos de Bitencourt, Carlos Franco Voegeli, Gabriela dos Santos Onzi e mais 3Revista Brasileira de Hematologia e Hemoterapia2013

    Background: The speed and quality of information have become essential items in the release of laboratory reports. The Sysmex®SP1000-I device has been developed to prepare and stain smear slides. However, for a device to be cleared for use in the laboratory routine it must pass through a validation process. Objective…

  4. Immature platelets: A useful tool for thrombocytopenia etiology classification in adults

    Raphael Ferreira Pimentel, Tayná Regina Leal dos Santos, Marcos André Cavalcanti Bezerra e mais 2Hematology, Transfusion and Cell Therapy2026

    Abstract Introduction The etiology of thrombocytopenia is diverse with heterogenous clinical manifestations which demand the correct diagnosis and appropriate management. The immature platelet fraction is associated with new platelet release from the bone marrow by thrombopoiesis. The clinical utility of this…

  5. Validation of the mindray BC6000 hematology analyzer for erythroblast counting in peripheral blood

    Lacy Brito Junior, Adna dos Santos Caldas, Vanessa Ingrid Cardoso Pereira e mais 2Jornal Brasileiro de Patologia e Medicina Laboratorial2022

    ABSTRACT Introduction Differential counting of erythroblasts in blood samples by hematology analyzers still has limitations. Technological advances in blood count equipment have proposed the fully automated counting of these cells, however, not without its validation. Objective Validate the automated count of…

  6. Automated immature granulocyte count in patients of the intensive care unit with suspected infection

    Letícia R. Lima, Gustavo S. P. Cunha, Keite S. Nogueira e mais 1Jornal Brasileiro de Patologia e Medicina Laboratorial2019citado por 2 artigos

    ABSTRACT Introduction: Diagnosing infections in intensive care unit (ICU) patients is vital to provide appropriate therapies. Hematological analyzers perform automated immature granulocyte counts (IG) quickly and with no additional cost when compared to traditional microbiological cultures. Elevated IG is directly…

  7. Evaluation of pleural and ascitic fluid analysis on the Sysmex XE-5000 hematology analyzer

    Regielly Caroline R. Cognialli, Samuel Ricardo Comar, Angela Maria de Souza e mais 1Jornal Brasileiro de Patologia e Medicina Laboratorial2017

    ABSTRACT Introduction: Body fluid (BF) analysis is critical to the diagnosis and monitoring of several pathological conditions. The limitations of manual cell counts have led to greater interest in the development of automated BF analysis. Objective: To evaluate the analytical performance of the Sysmex XE-5000…

  8. Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements

    Grace Kelly Martins Carneiro, Juliano Alves Roque, Aguinaldo Silva Garcez Segundo e mais 1Dental Press Journal of Orthodontics2015citado por 1 artigo

    OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled…

  9. Evaluation of RDW-CV, RDW-SD, and MATH-1SD for the detection of erythrocyte anisocytosis observed by optical microscopy

    Fernando Augusto Caporal e Samuel Ricardo ComarJornal Brasileiro de Patologia e Medicina Laboratorial2013

    INTRODUCTION AND OBJECTIVE: To evaluate the performance of red cell distribution width reported statistically as coefficient of variation (RDW-CV), standard deviation (RDW-SD), and mathematical deduction of 1 standard deviation (SD) around mean corpuscular volume (MATH-1SD) in identifying anisocytosis in automated…

  10. Are the review criteria for automated complete blood counts of the International Society of Laboratory Hematology suitable for all hematology laboratories?

    Samuel Ricardo Comar, Mariester Malvezzi e Ricardo PasquiniRevista Brasileira de Hematologia e Hemoterapia2014citado por 2 artigos

    OBJECTIVE: to verify whether the review criteria for automated blood counts suggested by the International Consensus Group for Hematology Review of the International Society for Laboratory Hematology are suitable for the Hematology Laboratory of Hospital de Clinicas, Universidade Federal do Paraná.METHODS: initially…

  11. An irrigation controller mechanically actuated by soil-water tension: I - Design, development and laboratory evaluations

    Alexsandro C. S. Almeida, Tarlei A. Botrel, Steven R. Raine e mais 3Revista Brasileira de Engenharia Agrícola e Ambiental2017

    ABSTRACT The objective of this study was to develop and evaluate an irrigation controller that was mechanically actuated by soil-water tension within laboratory conditions. The controller was designed and constructed using readily available hydraulic fittings and other componentry. The main components of the…