acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Walton Nosé”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Sight-dependent quality of life and ophthalmic findings in a group of Brazilian patients with multiple sclerosis

    Yára Dadalti Fragoso, Ricardo Menon Nosé, Regina Aidar Menon Nosé e mais 3Arquivos de Neuro-Psiquiatria2011

    OBJECTIVE: To assess the visual quality of life in patients with multiple sclerosis (MS), and to observe whether this parameter could be correlated to the findings of the ophthalmologic examination. METHOD: The translated and validated 25-Item National Eye Institute Visual Function Questionnaire (VFQ-25) was used to…

  2. Ceratoplastia lamelar profunda com viscodissecção da membrana de Descemet

    Cláudia M. Francesconi, Adriana S. Forseto, Regina M. Nosé e mais 1Arquivos Brasileiros de Oftalmologia2001citado por 2 artigos

    Objetivo: Avaliar a eficácia da técnica de ceratoplastia lamelar profunda preservando a membrana de Descemet e as células endoteliais do paciente, com a utilização de botão esclero-corneano. Métodos: Foram realizadas 14 ceratoplastias lamelares com viscodissecção da membrana de Descemet do receptor usando sulfato de…

  3. Avaliação do envelhecimento do cristalino em olhos normais

    Lucila Grandberg, Adriana dos Santos Forseto, Renate Ferreira de Souza e mais 2Arquivos Brasileiros de Oftalmologia2001citado por 2 artigos

    Objetivo: Avaliar alterações do cristalino relacionadas à idade, em olhos normais, analisando-se sua densidade e espessura, além da profundidade da câmara anterior (PCA). Métodos: Foram estudados 120 olhos de 60 pacientes hígidos por meio do sistema Scheimpflug. Os pacientes foram distribuídos em 6 grupos: Grupo I, 10…

  4. Diplopia monocular pós excimer laser

    Cristiane S. Neves, Paulo Schor, Regina M. Nosé e mais 2Arquivos Brasileiros de Oftalmologia1995

    RESUMO Relata-se um caso de uma paciente submetida a Ceratectomia Fotorefrativa que no pós-operatório apresentou diplopia monocular devido a descentração do tratamento.

  5. Ceratocone suspeito em pacientes candidatos à ceratotomia radial

    Renato Augusto Neves, Paulo Schor, Regina M. Nosé e mais 1Arquivos Brasileiros de Oftalmologia1994citado por 2 artigos

    RESUMO Pacientes portadores de ceratocone inicial ou que apresentam cones em áreas fora do eixo visual, dificilmente podem ser identificados por métodos tradicionais como a refração e a ceratometria central. Portadores de ceratocone submetidos a Ceratotomia Radial (CR) podem ter resultados desastrosos que…

  6. PRK versus LASIK para correção de miopia baixa e moderada

    Adriana dos Santos Forseto, Regina Aidar Menon Nosé e Walton NoséArquivos Brasileiros de Oftalmologia2000citado por 4 artigos

    Objetivo: Comparar, por meio de um estudo prospectivo e bilateral randomizado, a eficácia, segurança e previsibilidade das técnicas de ceratectomia fotorrefrativa (PRK) e "excimer laser in situ keratomileusis" (LASIK) para o tratamento da miopia baixa e moderada. Métodos: Foram incluídos dezessete pacientes (34 olhos)…

  7. Implante de lente de câmara anterior para correção da miopia em olhos fácicos

    Luciana L. Vanzella, Walton Nosé, Paulo Schor e mais 3Arquivos Brasileiros de Oftalmologia1997citado por 2 artigos

    RESUMO Objetivo: O presente estudo avalia a segurança e a eficácia dos implantes de lentes de câmara anterior em olhos fácicos para a correção da miopia. Métodos: Foram estudadas, retrospectivamente, a acuidade visual com e sem correção, a refratometria, a contagem endotelial e a incidência de complicações intra e…

  8. Clinical experience with the first 40 cases with femtosecond laser cataract surgery technology: safety of the learning curve

    Joao Crispim, Ricardo Nose, Ana Claudia Medeiros A. Garcia e mais 2Revista Brasileira de Oftalmologia2015citado por 1 artigo

    ABSTRACT Objective: To evaluate the introduction of the femtosecond laser (FSL) to perform the key steps of the traditional cataract surgery process and the operational difficulties and safety of this new technology during routine use in an operating room in Brazil. Methods A retrospective study was conducted using…

  9. Keratoconus false-positive screening rates in eyes with pterygium: tomographic and biomechanical artifacts

    Pablo Felipe Rodrigues, Felipe A. Casseb dos Santos, Bernardo Kaplan Moscovici e mais 3Arquivos Brasileiros de Oftalmologia2026

    ABSTRACT Purpose: To investigate tomographic and biomechanical screening artifacts associated with primary pterygium that may mimic keratoconus-like patterns before and after surgical excision. Methods: Twenty-five eyes with primary pterygium underwent Scheimpflug corneal tomography and dynamic corneal response…

  10. Measurement of the visual axis through two different methods: quantification and differences for measuring chord μ

    Pablo Felipe Rodrigues, Bernardo Kaplan Moscovici, Luciano Lamazales e mais 4Arquivos Brasileiros de Oftalmologia2024

    ABSTRACT Purpose: To compare the differences between the apparent and actual chord μ. Methods: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion…

  11. Measurement of the visual axis through two different methods: quantification and differences for measuring chord μ

    Pablo Felipe Rodrigues, Bernardo Kaplan Moscovici, Luciano Lamazales e mais 4Arquivos Brasileiros de Oftalmologia2023citado por 10 artigos

    ABSTRACT Purpose: To compare the differences between the apparent and actual chord μ. Methods: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion…

  12. Association between keratoconus, ocular allergy, and sleeping behavior

    Rodrigo Teixeira Santos, Bernardo Kaplan Moscovici, Flávio Eduardo Hirai e mais 3Arquivos Brasileiros de Oftalmologia2021citado por 4 artigos

    ABSTRACT Purpose: To compare the severity and laterality of keratoconus according to allergic rhinitis, scratching and sleeping habits, and manual dexterity. Methods: Objective assessments regarding allergic rhinitis, eye itching, and slee­ping position among patients with keratoconus (diagnosed based on corneal…

  13. Descemet membrane endothelial keratoplasty in multifocal pseudophakic eyes

    Nicolas Cesário Pereira, Evandro Ribeiro Diniz, Ramon Coral Ghanem e mais 4Arquivos Brasileiros de Oftalmologia2018

    ABSTRACT Purpose: This report describes the use of Descemet membrane endothelial keratoplasty for the management of endothelial decompensation after multifocal intraocular lens implantation. Methods: In this retrospective study, we reviewed and assessed the surgical outcomes of 9 patients (9 eyes) who underwent…

  14. Thickness and immunohistochemistry of LASIK flaps created by different femtosecond lasers in eye-bank corneas

    Grazielly Martins Peixoto de Oliveira, Walton Nosé, Maria Lúcia Zaidan Dagli e mais 3Arquivos Brasileiros de Oftalmologia2018

    ABSTRACT Purpose: The aim of this study was to compare the corneal cell viability and thickness of LASIK flaps created by 3 femtosecond lasers in eye-bank human corneas. Methods: Forty-five eye-bank human sclerocorneal buttons (15 corneas in each group) were examined after the creation of 120 mm-thick laser-assisted…

  15. In vivo ultrathin Descemet stripping automated endothelial keratoplasty with a low-energy and high-frequency femtosecond laser

    Gustavo Victor, Walton Nosé, Sidney Júlio de Faria e Sousa e mais 2Arquivos Brasileiros de Oftalmologia2014

    This case report describes the production of an ultrathin endothelial donor corneal lamella using a femtosecond laser with low energy and a high frequency. In addition, we report its use in vivo in an eye with pseudophakic bullous keratopathy. The outcomes were observed 3 months after surgery in terms of the change in…

  16. Analysis of low-energy and high-frequency femtosecond laser for the construction of deep anterior donor corneal lamellae

    Gustavo Victor, Walton Nosé, Sidney Julio de Faria e Sousa e mais 2Revista Brasileira de Oftalmologia2014

    Purpose: To evaluate the efficacy and reliability of a low-energy femtosecond laser with a high repetition rate for construction of deep anterior donor corneal lamellae. Methods: This was a prospective laboratory investigation. Twenty-five human corneal buttons were femtosecond laser cut to create thick anterior…

  17. Intracapsular dexamethasone implant in patients undergoing phacoemulsification and intraocular lens implantation

    Lucas Monferrari Monteiro Vianna, Lincoln Leme Freitas, Walton Nosé e mais 4Arquivos Brasileiros de Oftalmologia2013citado por 1 artigo

    PURPOSE: To relate the outcomes of 7 eyes of 7 patients in which a dexamethasone 0.7 mg implant (Ozurdex®) was placed inside the capsule bag after phacoemulsification and intraocular lens (IOL) implantation and compare with the fellow eyes, that were operated by the same technique and received dexamethasone eyedrops…

  18. Congenital cataract surgery with intraocular lens implantation in microphthalmic eyes: visual outcomes and complications

    Marcelo Carvalho Ventura, Virgínia Vilar Sampaio, Bruna Vieira Ventura e mais 2Arquivos Brasileiros de Oftalmologia2013

    PURPOSE: To report the visual outcomes and complications of congenital cataract surgery with primary intraocular lens implantation in microphthalmic eyes of children younger than 4 years of age. METHODS:This retrospective interventional case series included 14 microphthalmic eyes from 10 children who underwent…

  19. Recanalização do ducto nasolacrimal com radiofrequência: estudo preliminar

    Eduardo Alonso Garcia, Marco Antonio Campos Machado, João Amaro Ferrari da Silva e mais 1Arquivos Brasileiros de Oftalmologia2012

    OBJETIVO: Avaliar a reconstituição do ducto nasolacrimal com o uso de radiofrequência para restabelecimento do fluxo lacrimal nos casos de obstrução da via lacrimal excretora. MÉTODOS: O procedimento foi realizado em 16 olhos de 16 pacientes (13 femininos e 3 masculinos) pelo mesmo cirurgião, utilizando aparelho de…

  20. Lentes fácicas de câmara anterior

    Walton Nosé e Adriana dos Santos ForsetoRevista Brasileira de Oftalmologia2012citado por 1 artigo

    Os implantes em olhos fácicos apresentam-se como uma opção para a correção de altas ametropias. De acordo com sua localização podem ser classificados como de câmara anterior ou posterior, sendo que os primeiros subdividem-se em fixação iriana ou de suporte angular. Além da correção da miopia, as lentes de fixação…