Arquivos Brasileiros de Oftalmologia2024
Measurement of the visual axis through two different methods: quantification and differences for measuring chord μ
Pablo Felipe Rodrigues, Bernardo Kaplan Moscovici, Luciano Lamazales, Marcela Mara Silva Freitas, José Álvaro Pereira Gomes, Walton Nosé e Mauro Silveira Campos
em inglês
resumo
ABSTRACT Purpose: To compare the differences between the apparent and actual chord μ. Methods: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion criteria were patients aged 21-71 years, able to provide informed consent, myopia up to 4D, and anterior topographic astigmatism up to 1D. Patients using contact lenses, those with previous eye diseases or surgeries, corneal opacities, corneal tomographic changes, or suspected keratoconus were excluded. Results: Altogether, 116 eyes of 58 patients were analyzed. The patients’ mean age was 30.69 (±7.85) years. In the correlation analyses, Pearson’s correlation coefficient of 0.647 indicates a moderate positive linear relationship between apparent and actual chord μ. The mean actual and apparent chord μ were 226.21 ± 128.53 and 278.66 ± 123.90 μm, respectively, with a mean difference of 52.45 μm (p=0.01). The analysis of mean pupillary diameter resulted in 5.76 mm using the HD Analyzer and 3.31 mm using the Pentacam. Conclusions: We found a correlation between the two measurement devices, and even though we found considerable differences, both can be used in daily practice. Given their differences, we should respect their peculiarities as well.
como citar · ABNT NBR 6023
RODRIGUES, Pablo Felipe et al. Measurement of the visual axis through two different methods: quantification and differences for measuring chord μ. Arquivos Brasileiros de Oftalmologia, 2024. DOI: 10.5935/0004-2749.2022-0035.
Referências
18 obras citadas · 1 no acervo
- 1H Basmak, A Sahin, N Yildrim e mais 2. Measurement of angle kappa with synoptophore and Orbscan II in a normal population. J Refract Surg, 2007quem mais cita →
- 2DA Atchison, G Smith e WN Charman. Error in determining the direction of the visual axis in the presence of defocus. Ophthalmic Physiol Opt, 1998quem mais cita →
- 3DH Chang e GO Waring 4th. The subject-fixated coaxially sighted corneal light reflex: a clinical marker for centration of refractive treatments and devices. Am J Ophthalmol, 2014quem mais cita →
- 4O Kermani, U Oberheide, K Schiedt e mais 2. Outcomes of hyperopic LASIK with the NIDEK NAVEX platform centered on the visual axis or line of sight. J Refract Surg, 2009quem mais cita →
- 5M Pande e JS Hillman. Optical zone centration in keratorefractive surgery. Entrance pupil center, visual axis, coaxially sighted corneal reflex or geometric corneal center?. Ophthalmology, 1993quem mais cita →
- 6DZ Reinstein, M Gobbe e TJ Archer. Coaxially sighted corneal light reflex versus entrance pupil center centration of moderate to high hyperopic corneal ablation in eyes with small and large angle kappa. J Refract Surg, 2013quem mais cita →
- 7H Uozato e DL Guyton. Centering corneal surgical procedures. Am J Ophthalmol, 1987quem mais cita →
- 8R Solomon, A Barsam, A Voldman e mais 3. Argon laser iridoplasty to improve visual function following intraocular lens implantation. J Refract Surg, 2012quem mais cita →
- 9S Okamoto, K Kimura, M Funakura e mais 3. Comparison of myopic LASIK centered on the coaxially sighted corneal light reflex or line of sight. J Refract Surg, 2009quem mais cita →
- 10E Guilbert, A Saad e D. Gatinel. AcuTarget measurements: repeatability and comparison to OPD-Scan III. J Refract Surg, 2014quem mais cita →
- 11JT. Holladay. Apparent chord mu and actual chord mu and their clinical value. J Cataract Refract Surg, 2019quem mais cita →
- 12JM Bland e DG. Altman. Calculating correlation coefficients with repeated observations. Part 1-correlation with subjects. BMJ, 1995quem mais cita →
- 13JM Bland e DG. Altman. Calculating Correlation Coefficients with Repeated Observations. Part 2-Correlation Between Subjects. BMJ, 1995quem mais cita →
- 14M Rodrigues-Vallejo, DP Piñero e J Fernández. Avoiding misinterpretations of kappa angle for clinical research studies with Pentacam. J Optom, 2019quem mais cita →
- 15LC Rios, PG Silva, AM Canamary Junior e mais 3. Centration in refractive surgery. Arq Bras Oftalmol [Internet], 2020no acervo →
- 16P Narang, J Holladay, A Agarwal e mais 3. Application of Purkinje images for pinhole pupilloplasty and relevance to chord length mu. J Cataract Refract Surg, 2019quem mais cita →
- 17S Arba Mosquera, S Verma e C McAlinden. Centration axis in refractive surgery. Eye Vis (Lond), 2015quem mais cita →
- 18JM Bland e DG Altman. Measuring agreement in method comparison studies. Stat Methods Med Res, 1999quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda