acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Visual acuity tests”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Comparison of sweep visual evoked potential of visual acuity and Snellen visual acuity in healthy and amblyopic children

    Murat Kasikci, Tuncay Kusbeci, Guliz Yavas e mais 2Arquivos Brasileiros de Oftalmologia2023

    ABSTRACT Purpose: To evaluate the visual acuity of healthy and amblyopic children using sweep visual evoked potential and compare the results with those of Snellen visual acuity testing. Methods: A total of 160 children aged 6-17 years were included in the study. Of these, 104 (65%) were aged 7-17 years old, able to…

  2. Age norms for monocular grating acuity measured by sweep-VEP in the first three years of age

    Solange Rios Salomão, Fabio Ejzenbaum, Adriana Berezovsky e mais 2Arquivos Brasileiros de Oftalmologia2008citado por 6 artigos

    PURPOSE: To determine age norms for grating visual acuity and interocular acuity differences measured by the sweep-visually evoked potentials (VEP) technique in the first three years of life. METHODS: Monocular grating visual acuity was measured using the sweep-VEP in 67 healthy normal infants and children in the…

  3. Grating visual acuity impairment assessed by sweep visually evoked potentials in children with optic pathway tumors unable to perform optotype acuity tests

    Patrícia de Freitas Dotto, Adriana Berezovsky, Andrea Maria Cappellano e mais 6Arquivos Brasileiros de Oftalmologia2021

    ABSTRACT Purpose: To determine visual impairment due to optic pathway tumors in children unable to perform recognition acuity tests. Methods: Grating visual acuity scores, in logMAR, were obtained by sweep visually evoked potentials (SVEP) in children with optic pathway tumors. The binocular grating visual acuity…

  4. Microperimetry differences in macular sensitivity threshold between first and second tested eyes

    Natacha B. Junqueira, Luiz H. Lima, Rodrigo B. Ferreira e mais 3Arquivos Brasileiros de Oftalmologia2021

    ABSTRACT Purpose: To comparatively assess the macular sensitivity threshold of microperimetry and the fixation stability between the first (right) and second (left) tested eye of normal participants. Methods: Thirty healthy patients were randomly assigned to two groups. The participants underwent microperimetry in the…

  5. A need for standardization in visual acuity measurement

    Hina Patel, Nathan Congdon, Glenn Strauss e mais 1Arquivos Brasileiros de Oftalmologia2017

    ABSTRACT Standardization of terminologies and methods is increasingly important in all fields including ophthalmology, especially currently when research and new technology are rapidly driving improvements in medicine. This review highlights the range of notations used by vision care professionals around the world for…

  6. Tumbling-hand optotype: a novel gesture-based tool for visual acuity assessment in neurodivergent populations

    Juan Carlos Costa, Daniela Leite Pinto e Mariana Thayna OliveiraRevista Brasileira de Oftalmologia2026

    ABSTRACT Objective: This study aimed to validate the psychometric properties, feasibility, and clinical utility of the Tumbling-Hand test. Methods: The validation process involved two phases. In neurotypical participants, VA thresholds of the Tumbling-Hand test were compared with the printed Tumbling E test, with…

  7. Real-world evidence of the use of Cloudscaper optotypes versus LEA symbols for virtual or digital visual acuity measurement in children aged 3 to 16 years

    Cristiana Soares Ronconi, Julia Dutra Rossetto, Luisa Moreira Hopker e mais 3Arquivos Brasileiros de Oftalmologia2026

    ABSTRACT Purpose: This cross-sectional study compared best-corrected visual acuity obtained using Cloudscaper symbols, a novel optotype developed according to ETDRS specifications for children’s virtual screening, with that obtained using LEA symbols. Methods: A total of 560 children aged 3-16 yr underwent visual…

  8. Clinical validation of a cross-platform digital visual acuity measurement system

    Juan Carlos Costa, Daniel Machado de Amorim e Paulo Roberto LinsRevista Brasileira de Oftalmologia2024

    ABSTRACT Objective: To validate visual acuity measurements using a cross-platform system in an ophthalmological setting. Methods: Visual acuity was assessed at a distance of 5m using two different modalities: printed and digital optotypes. The devices included Android, LG WebOS and Samsung Tizen smart TVs. Optotypes…

  9. Remote visual screening education for teachers: a prospective longitudinal interventional study

    Laura Goldfarb Cyrino, Paulo Vigga, Matheus Enrico Dias Vaz Monteiro e mais 4einstein (São Paulo)2026

    ABSTRACT Objective: We aimed to assess the effectiveness of a remote training program designed to improve the ability of education professionals to conduct visual screening in children aged 2-5 years. Methods: This prospective longitudinal interventional study included 42 early childhood education professionals from a…

  10. Development of the Portuguese version of a standardized reading test: the Radner-Coimbra Charts

    Andreia Martins Rosa, Cláudia Louro Farinha, Wolfgang Radner e mais 3Arquivos Brasileiros de Oftalmologia2016citado por 1 artigo

    ABSTRACT Purpose: To develop 27 short sentence optotypes for the Portuguese version of the Radner Reading Charts. Methods: Thirty-four Portuguese sentences were constructed following the concept of the Radner Reading Charts to obtain highly comparable sentences in terms of lexical difficulty, syntactical complexity…

  11. Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique

    Frederico França Marques, Ricardo Mitsuo Sato, Brenda Biagio Chiacchio e mais 3Arquivos Brasileiros de Oftalmologia2009citado por 1 artigo

    PURPOSE: To evaluate the distance, intermediate and near visual acuity of patients with bilateral cataract operated on both eyes corrected for distance in one eye and for near in the fellow eye, as well as, their stereo acuity and their general satisfaction. SETTINGS: Hospital de Olhos de São Paulo and Complexo…

  12. Cognitive, motor, and visual development in healthy children in the first 42 months of life

    Ana Carla Ramos Vieira da Costa, Nívea Nunes Ferraz e Adriana BerezovskyArquivos Brasileiros de Oftalmologia2021

    ABSTRACT Purpose: The Bayley Scales of Infant and Toddler Development-Third Edition (Bayley-III) is a tool for measuring the developmental status of children, including cognitive and motor functioning, in the first three years of life. This study aims to evaluate the correlation between grating visual acuity and…