Arquivos Brasileiros de Oftalmologia2021
Microperimetry differences in macular sensitivity threshold between first and second tested eyes
Natacha B. Junqueira, Luiz H. Lima, Rodrigo B. Ferreira, Denny Marcos Garcia, João M. Furtado e Rodrigo Jorge
em inglês
resumo
ABSTRACT Purpose: To comparatively assess the macular sensitivity threshold of microperimetry and the fixation stability between the first (right) and second (left) tested eye of normal participants. Methods: Thirty healthy patients were randomly assigned to two groups. The participants underwent microperimetry in the fast mode and expert mode in groups I and II, respectively. Each participant underwent a single test and the right eye was tested first. Results: The mean macular sensitivity threshold (± standard deviation [SD]) was 24.5 ± 2.3 dB and 25.7 ± 1.1 dB in the first (right) and second (left) eyes of group I, respectively (p=0.0415) and 26.7 ± 4.5 dB and 27.3 ± 4.0 dB in the first (right) and second (left) eyes of group II, respectively (p=0.58). There was no statistically significant difference between eyes in either group (p=0.1512). Regarding fixation stability (evaluated in the microperimetry expert mode group), the mean ± SD percentage of fixation points within the 1-degree central macula (P1) was 87.9 ± 11.5% in the right eye and 93.8 ± 6.6% in the left eye. The paired t-test did not show a statistically significant difference between eyes (p=0.140). Mean ± SD P2 value was 95.5 ± 4.9% in the right eye and 98.5 ± 2.1% in the left eye. The analysis demonstrated an increase in the percentage of fixation points in the second tested eye compared with the first one (paired t-test= 2.364; p=0.034). There was a negative correlation between the macular sensitivity threshold of the right eye and the duration of the examination for both groups (microperimetry expert mode: r=-0.717; p=0.0026; microperimetry in the fast mode: r=-0.843; p<0.0001). Conclusion: Mean macular sensitivity threshold was higher in the second tested eye in the microperimetry in the fast mode group and was similar in both eyes in the expert mode. Our data suggest that comprehension of the examination by the individual may impact the results of the microperimetry test.
como citar · ABNT NBR 6023
JUNQUEIRA, Natacha B. et al. Microperimetry differences in macular sensitivity threshold between first and second tested eyes. Arquivos Brasileiros de Oftalmologia, 2021. DOI: 10.5935/0004-2749.20210034.
Referências
13 obras citadas
- 1JM Wild. Techniques and developments in automated perimetry: a review. Ophthalmic Physiol Opt, 1988quem mais cita →
- 2K Rohrschneider, S Bultmann e C Springer. Use of fundus perimetry (microperimetry) to quantify macular sensitivity. Prog Retin Eye Res, 2008quem mais cita →
- 3H Imai e K Ohta. Microperimetric determination of retinal sensitivity in areas of dissociated optic nerve fiber layer following internal limiting membrane peeling. Jpn J Ophthalmol, 2010quem mais cita →
- 4A Heijl, G Lindgren e J Olsson. The effect of perimetric experience in normal subjects. Arch Ophthalmol, 1989quem mais cita →
- 5PR Jones, N Yasoubi, M Nardini e mais 1. Feasibility of macular integrity assessment (MAIA) microperimetry in children: sensitivity, reliability, and fixation stability in healthy observers. Invest Ophthalmol Vis Sci, 2016quem mais cita →
- 6MT Barboni, Z Szepessy, DF Ventura e mais 1. Individual test point fluctuations of macular sensitivity in healthy eyes and eyes with age-related macular degeneration measured with microperimetry. Trans Vis Sci Tech, 2018quem mais cita →
- 7MAIA. Macular Integrity Assessment. Microperimetry Handbookquem mais cita →
- 8S Balasubramanian, A Uji, J Lei e mais 3. Interdevice comparison of retinal sensitivity assessments in a healthy population: the CenterVue MAIA and the Nidek MP-3 microperimeters. Br J Ophthalmol, 2018quem mais cita →
- 9MU Morales, S Saker, C Wilde e mais 8. Reference Clinical Database for Fixation Stability Metrics in Normal Subjects Measured with the MAIA Microperimeter. Transl Vis Sci Technol, 2016quem mais cita →
- 10Z Wu, LN Ayton, RH Guymer e mais 1. Intrasession test-retest variability of microperimetry in age-related macular degeneration. Invest Ophthalmol Vis Sci, 2013quem mais cita →
- 11A Molina-Martín, DP Piñero e RJ Pérez-Cambrodí. Normal values for microperimetry with the MAIA microperimeter: sensitivity and fixation analysis in healthy adults and children. Eur JOphthalmol, 2017quem mais cita →
- 12MB Parodi, G Triolon, M Morales e mais 3. MP1 and MAIA fundus perimetry in healthy subjects and patients affected by retinal dystrophies. Retina, 2015quem mais cita →
- 13C Hudson, JM Wild e EC O'Neill. Fatigue effects during a single session of automated static threshold perimetry. Invest Ophthalmol Vis Sci, 1994quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda