Arquivos Brasileiros de Oftalmologia2024

Normative data for macular perimetry using the MP-3 microperimeter in healthy individuals

Taurino dos Santos Rodrigues Neto, Epitácio Dias da Silva Neto, Alex Haruo Higashi, Bianca Partezani Megnis, Maria Aparecida Onuki Haddad, Mário Luiz Ribeiro Monteiro e Leandro Cabral Zacharias

em inglês

cita 14 obras

resumo

ABSTRACT Purpose: Microperimetry has been used for several years as a form of visual function testing in patients with retinal diseases. Normal microperimetry values obtained with microperimeter MP-3 have not yet been fully published, and baseline values for topographic macular sensitivity and correlations with age and sex are needed to establish degrees of impairment. This study aimed to determine values for light sensitivity thresholds and fixation stability using the MP-3 in healthy individuals. Methods: Thirty-seven healthy volunteers (age, 28-68 years), underwent full-threshold microperimetry using a 4-2 (fast) staircase strategy with the standard Goldmann III stimulus size and 68 test points positioned identically to those in the Humphrey Field Analyzer 10-2 test grid. The fixation stability was simultaneously recorded during the microperimetry test. The relationship between global sensitivity and age was calculated using linear regression analysis. Results: Microperimetry was performed on 37 participants (74 eyes). The global mean sensitivity was 29.01 ± 1.44 (range, 26-31) dB. The mean central sensitivity at 2° measured by the MP-3 was 28.5 ± 1.77 dB in the right eye (OD) and 28.75 ± 1.98 dB in the left eye (OS). The total median fixation stability values within 2° and 4° were 80% and 96%, respectively. The linear regression analysis also revealed an age-related global sensitivity decline per year of -0.051 dB ± 0.018 (OD) and -0.078 dB ± 0.021 (OS). Conclusions: Microperimetry performed with the MP-3 allows for an automatic, accurate, and topography-specific examination of retinal sensitivity thresholds. The results of this study provide a normal and age-matched database of MP-3 microperimetry.

como citar · ABNT NBR 6023

RODRIGUES NETO, Taurino dos Santos et al. Normative data for macular perimetry using the MP-3 microperimeter in healthy individuals. Arquivos Brasileiros de Oftalmologia, 2024. DOI: 10.5935/0004-2749.2021-0472.

Referências

14 obras citadas

  1. 1M Laishram, K Srikanth, AR Rajalakshmi e mais 2. Microperimetry - A new tool for assessing retinal sensitivity in macular diseases. J Clin Diagn Res, 2017quem mais cita →
  2. 2SN Markowitz e SV Reyes. Microperimetry and clinical practice: an evidence-based review. Can J Ophthalmol, 2013quem mais cita →
  3. 3JH Acton e VC Greenstein. Fundus-driven perimetry (microperimetry) compared to conventional static automated perimetry: similarities, differences, and clinical applications. Can J Ophthalmol, 2013quem mais cita →
  4. 4S Vujosevic, E Midena, E Pilotto e mais 3. Diabetic macular edema: correlation between microperimetry and optical coherence tomography findings. Invest Ophthalmol Vis Sci, 2006quem mais cita →
  5. 5N Yamaike, M Kita, A Tsujikawa e mais 2. Perimetric sensitivity with the micro perimeter 1 and retinal thickness in patients with branch retinal vein occlusion. Am J Ophthalmol, 2007quem mais cita →
  6. 6E Midena, S Vujosevic, E Convento e mais 3. Microperimetry and fundus autofluorescence in patients with early age-related macular degeneration. Br J Ophthalmol, 2007quem mais cita →
  7. 7S Palkovits, N Hirnschall, S Georgiev e mais 2. Test-retest reproducibility of the microperimeter MP-3 with fundus image tracking in healthy subjects and patients with macular disease. Transl Vis Sci Technol, 2018quem mais cita →
  8. 8E Midena, S Vujosevic e F Cavarzeran. Normal values for fundus perimetry with the microperimeter MP1. Ophthalmology, 2010quem mais cita →
  9. 9VA Shah e KV Chalam. Values for macular perimetry using the MP-1 microperimeter in normal subjects. Ophthalmic Res, 2009quem mais cita →
  10. 10R Fujino, R Asaoka, S Aoki e mais 3. The usefulness of the retinal sensitivity measurement with a microperimetry for predicting the visual prognosis of branch retinal vein occlusion with macular edema. Graefes Arch Clin Exp Ophthalmol, 2020quem mais cita →
  11. 11S Balasubramanian, A Uji, J Lei e mais 3. Interdevice comparison of retinal sensitivity assessments in a healthy population: the CenterVue MAIA and the Nidek MP-3 microperimeters. Br J Ophthalmol, 2018quem mais cita →
  12. 12BJ Lachenmayr, S Kojetinsky, N Ostermaier e mais 3. The different effects of aging on normal sensitivity in flicker and light-sense perimetry. Invest Ophthalmol Vis Sci, 1994quem mais cita →
  13. 13CA Johnson, AJ Adams e RA Lewis. Evidence for a neural basis of age-related visual field loss in normal observers. Invest Ophthalmol Vis Sci, 1989quem mais cita →
  14. 14MTS Barboni, Z Szepessy, DF Ventura e mais 1. Individual test point fluctuations of macular sensitivity in healthy eyes and eyes with age-related macular degeneration measured with microperimetry. Transl Vis Sci Technol, 2018quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações