acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Titanium alloy (Ti-6Al-4V)”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Effect of Martensitic Transformation on Elastic Modulus Anisotropy of Ti-6Al-4V Alloy

    Zhongxue Feng, Yingxiang Yang, Zhichao Xu e mais 1Materials Research2018

    The Young's modulus (E), Poisson's ratio (ν) and anisotropy parameter (AG) of α' phase, which obtained from different solution treatment and water quenching temperature, were investigated using first-principles calculations based on density functional theory (DFT). The calculation results showed that the Z-axis value…

  2. Surface, microstructural, and adhesion strength investigations of a bioactive hydroxyapatite-titanium oxide ceramic coating applied to Ti-6Al-4V alloys by plasma thermal spraying

    Renan Carreiro Rocha, André Gustavo de Sousa Galdino, Sidnei Nicodemos da Silva e mais 1Materials Research2018citado por 1 artigo

    Ti-6Al-4V alloy is employed in implants because of its good mechanical strength, excellent biocompatibility, and good resistance to corrosion in biological environments. Herein, a composite (HAp-TiO2, 50% by volume of both components) coating surface employing Ti-6Al-4V was characterized. Samples were analyzed post…

  3. Selective Laser Melting of Ti-6Al-4V Alloy: Correlation Between Processing Parameters, Microstructure and Corrosion Properties

    Marcio Sangali, Alessandra Cremasco, Juliano Soyama e mais 2Materials Research2023

    Additive Manufacturing technology has continually advanced, allowing microstructure and property optimization. In recent years, several studies have been carried out with the aim of understanding mechanisms of formation and evolution of the microstructure and, consequently, their influence on mechanical properties…

  4. Effect of Duplex Aging Heat Treatment on the Stress Corrosion Cracking Behavior of Ti-6Al-4V α+β Titanium Alloy in Methanol

    Paulo César Paroli Santos Junior e Edmilson Otoni CorreaMaterials Research2021

    The influence of duplex aging (DA) heat treatment and consequent microstructural changes in the stress corrosion cracking (SCC) resistance of Ti-6Al-4V α+β titanium alloy was examined through constant load SCC test and metallographic examination. The time for fracture (TFF) of duplex aged samples in the SCC test was…

  5. Comparative corrosion behavior of titanium alloys (ti-15mo and ti-6al-4v) for dental implants applications: A review

    Cátia S. D. Lopes, Mariana T. Donato e P. RamgiCorrosão e Protecção de Materiais2016

    Nowadays there is an increasing need of biocompatible materials due to the toxicity of the metals used. Focusing in dental implants, there are several problems concerning the corrosion of implants, for example, the high concentration of fluoride ions, which make an acid medium. Considering that titanium has excellent…

  6. Deformation and fracture of an alpha/beta titanium alloy

    A. Andrade, A. Morcelli e R. LoboMatéria (Rio de Janeiro)2010citado por 2 artigos

    Titanium alloys are used in the aero-spatial, energy and biomaterial industries among others and exhibit high specific strength and fracture toughness. Their mechanical properties show a strong dependence on the microstructure, especially on the size and morphology of the constituent phases. An experimental evaluation…

  7. Analysis of surface roughness and hardness in titanium alloy machining with polycrystalline diamond tool under different lubricating modes

    Goutam Devaraya Revankar, Raviraj Shetty, Shrikantha Srinivas Rao e mais 1Materials Research2014citado por 1 artigo

    The present work deals with the investigation on machining of difficult-to-machine material titanium alloy (Ti-6Al-4V) using poly crystalline diamond (PCD) tool under different coolant strategies, namely dry, flooded and MQL. Taguchi technique has been employed and the optimization results indicated that MQL…

  8. Controlled Pre-Corrosion Attack and Ultrasonic Fatigue Endurance of Titanium Alloy Ti-6Al-4V

    Ishvari F. Zuñiga Tello, Gonzalo M. Domínguez Almaraz, Manuel Guzmán Tapia e mais 1Latin American Journal of Solids and Structures2017

    Abstract Ultrasonic fatigue tests were carried out on titanium alloy Ti-6Al-4V on the base material and the pre-corroded specimen to assess the pre-corrosion effect on the fatigue life of this alloy. The pre-corrosion was obtained by immersion of specimens in an acid solution: hydrochloric acid with 1.4 of pH during 8…

  9. Insertion torque, flexural strength and surface alterations of stainless steel and titanium alloy orthodontic mini-implants: an in vitro study

    Gustavo Lopes PULS, Guido Artemio MARAÑÓN-VÁSQUEZ, Christian Andrew Vargas RAMOS e mais 5Dental Press Journal of Orthodontics2024

    ABSTRACT Objective: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. Methods: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks…

  10. Vickers hardness of cast commercially pure titanium and Ti-6Al-4V alloy submitted to heat treatments

    Sicknan Soares da Rocha, Gelson Luis Adabo, Guilherme Elias Pessanha Henriques e mais 1Brazilian Dental Journal2006citado por 4 artigos

    The purpose of this study was to evaluate the effect of heat treatments on the Vickers hardness of commercially pure titanium and Ti-6Al-4V castalloys. Six-millimeter-diameter cylindrical specimens were cast in a Rematitan System. Commercially pure titanium and Ti-6Al-4V alloy specimens were randomly assigned to 3…

  11. Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments

    Emilena Maria Castor Xisto Lima, Wander José da Silva, Juliana Silva Moura e mais 2Brazilian Oral Research2006citado por 1 artigo

    The aim of this study was to evaluate surface free energy (SFE), surface roughness (SR) and surface hardness (SH) of two commercially available materials for fabricating dental implant abutments. In addition, the specimens were investigated by scanning electron microscopy (SEM) to determine the surface morphology…

  12. Influence of the final temperature of investment healting on the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy

    Pedro César Garcia Oliveira, Gelson Luis Adabo, Ricardo Faria Ribeiro e mais 3Journal of Applied Oral Science2007

    The aim of the work was to evaluate the influence of the temperature of investment healting on the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy casting. Were obtained for the tensile strength test dumbbell rods that were invested in the Rematitan Plus investment and casting in the Discovery…

  13. Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloy

    João Paulo Lyra e Silva, Alfredo Júlio Fernandes Neto, Luís Henrique Araújo Raposo e mais 4Brazilian Dental Journal2012citado por 1 artigo

    The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the…

  14. Influence of Reactive Sputtering-Deposited Nb2O5 Coating On the Ti-6Al-4V Alloy Surfaces: Biomineralization, Antibacterial Activity, and Cell Viability Tests

    J. P. L. Nascimento, G. T. L. Teixeira, M. M. S. Obata e mais 6Materials Research2023

    Biomedical engineering has been constantly looking for the development of new materials that have bioactive surfaces and that are responsible for new bone formation, induce osteoblast differentiation and present antibacterial properties. Here, we present innovative and applied research to evaluate the influence of…

  15. Fatigue behavior and physical characterization of surface-modified Ti-6Al-4V ELI alloy by micro-arc oxidation

    Fernanda Potomati, Enrico José Giordani, Laís Tereza Duarte e mais 2Materials Research2012citado por 1 artigo

    Anodizing has proven an effective method for preparing bioactive titanium and has been the subject of many studies regarding the performance and biological characterization of the layers obtained. However, the fatigue behavior of titanium alloys, after undergoing this process is still poorly studied. This study aims…

  16. Three-dimensional characterization of pores in Ti-6Al-4V alloy

    Márcia Regina Baldissera, Paulo Rangel Rios, Luis Rogério Oliveira Hein e mais 1Materials Research2011citado por 1 artigo

    The direct three-dimensional characterization of opaque materials through serial sectioning makes possible to visualize and better quantify a material microstructure, using classical metallographic techniques coupled with computer-aided reconstruction. Titanium alloys are used as biomaterials for bone implants because…

  17. Evaluation of shot peening on the fatigue strength of anodized Ti-6Al-4V alloy

    Midori Yoshikawa Pitanga Costa, Herman Jacobus Cornelis Voorwald, Walter Luis Pigatin e mais 2Materials Research2006citado por 2 artigos

    The increasingly design requirements for modern engineering applications resulted in the development of new materials with improved mechanical properties. Low density, combined with excellent weight/strength ratio as well as corrosion resistance, make the titanium attractive for application in landing gears. Fatigue…

  18. Corrosion Behavior Analysis of Plasma-assited PVD Coated Ti-6Al-4V alloy in 2 M NaOH Solution

    Verônica Mara Cortez Alves de Oliveira, Carla Aguiar, Amira Muci Vazquez e mais 2Materials Research2017

    The work aims the study of the corrosion behavior of nitride plasma-assisted PVD coated Ti-6Al-4V alloy in 2 M NaOH at 25 and 60°C, using open-circuit potential (OCP) versus time measurements, potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). The uncoated Ti-6Al-4V alloy showed a passive…

  19. Assessment of the Fatigue Behavior of Ti-6Al-4V ELI Alloy with Surface Treated by Nd:YAG Laser Irradiation

    Fernanda Potomati, Leonardo Contri Campanelli, Paulo Sergio Carvalho Pereira da Silva e mais 4Materials Research2019citado por 1 artigo

    The effect of a surface treatment by Nd:YAG laser irradiation on the fatigue behavior of Ti-6Al-4V ELI was studied. Axial fatigue tests were performed to obtain S-N curves in polished and laser treated conditions. Roughness measurements and scanning electron microscopy were used to characterize the features of the…

  20. Influence of Si Coating on Interfacial Microstructure of Laser Joining of Titanium and Aluminium Alloys

    Aline Capella de Oliveira, André Felipe Ribeiro Moreira, Carina Barros Mello e mais 2Materials Research2018

    A common phenomenon in the dissimilar joints is the presence of brittle compounds in the joining interface region. The brittle phases can decrease by introduction of interlayers in the joining interface, such as silicon, that inhibits the formation of Al3Ti and AlTi3 phases in joining process between titanium and…