Anodizing has proven an effective method for preparing bioactive titanium and has been the subject of many studies regarding the performance and biological characterization of the layers obtained. However, the fatigue behavior of titanium alloys, after undergoing this process is still poorly studied. This study aims to investigate the influence of MAO (Micro-Arc Oxidation) process on the fatigue properties of titanium alloy Ti-6Al-4V. Therefore axial fatigue tests were performed to obtain SxN curves, of specimens in polished and anodized (MAO processed, phosphate salt solution, potential of 290 V) conditions. Roughness measurements, SEM, Raman spectra and X-ray photoelectron spectroscopy (XPS) analyses were used to characterize the features of the modified surface. SEM was also used to analyze the fatigue fractures of the tested specimens. The MAO process, with the parameters used in this investigation, had no influence on the fatigue behavior of the Ti-6Al-4V alloy, when compared to specimens without surface modification.

como citar · ABNT NBR 6023

POTOMATI, Fernanda et al. Fatigue behavior and physical characterization of surface-modified Ti-6Al-4V ELI alloy by micro-arc oxidation. Materials Research, 2012. DOI: 10.1590/S1516-14392012005000012.

Referências

31 obras citadas

  1. 1L Le Guéhennec, A Soueidan, P Layrolle e mais 1. Surface treatments of titanium dental implants for rapid osseointegration. Dental Materials, 2007quem mais cita →
  2. 2B Yang, M Uchida, H-M Kim e mais 2. Preparation of bioactive titanium metal via anodic oxidation treatment. Biomaterials, 2004quem mais cita →
  3. 3X Liu, PK Chu e C. Ding. Surface modification of titanium, titanium alloys, and related materials for biomedical applications. Materials Science and Engineering R, 2004quem mais cita →
  4. 4PT De Oliveira e A. Nanci. Nanotexturing of titanium-based surfaces upregulates expression of bone sialoprotein and osteopontin by cultured osteogenic cells. Biomaterials, 2004quem mais cita →
  5. 5D Krupa, J Baszkiewicz, JW Sobczak e mais 3. Influence of anodic oxidation on the bioactivity and corrosion resistance of phosphorus-ion implanted titanium. Vacuum, 2003quem mais cita →
  6. 6B Setzer, M Bächle, MC Metzger e mais 1. The gene-expression and phenotypic response of hFOB 1.19 osteoblasts to surface-modified titanium and zirconia. Biomaterial, 2009quem mais cita →
  7. 7S Vanzillotta, MS Sader, IN Bastos e mais 1. Improvement of in vitro titanium bioactivity by three different surface treatments. Dental Materials, 2006quem mais cita →
  8. 8S Cheng, D Wei, Y Zhou e mais 1. Preparation, cell response and apatite-forming ability of microarc oxidized coatings containing Si, Ca and Na on titanium. Ceramics International, 2011quem mais cita →
  9. 9Y Gao, B Gao, R Wang e mais 3. Improved biological performance of low modulus Ti-24Nb-4Zr-7.9Sn implants due to surface modification by anodic oxidation. Applied Surface Science, 2009quem mais cita →
  10. 10GB Souza, GG Lima, NK Kuromoto e mais 3. Tribo-mechanical characterization of rough, porous and bioactive Ti anodic layers. Journal of the Mechanical Behavior of Biomedical Materials, 2011quem mais cita →
  11. 11X Cui, H-M Kim, M Kawashita e mais 3. Preparation of bioactive titania films on titanium metal via anodic oxidation. Dental Materials, 2009quem mais cita →
  12. 12HJ Song, SH Park, SH Jeong e mais 1. Surface characteristics and bioactivity of oxide films formed by anodic spark oxidation on titanium in different electrolytes. Journal of Materials Processing Technology, 2009quem mais cita →
  13. 13NK Kuromoto, RA Simão e GA. Soares. Titanium oxide films produced on commercially pure titanium by anodic oxidation with different voltages. Materials Caracterization, 2007quem mais cita →
  14. 14D Krupa, J Baszkiewicz, JA Kozubowski e mais 3. Corrosion resistance and bioactivity of titanium after surface treatment by three different methods: ion implantation, alkaline treatment and anodic oxidation. Analytical and Bioanalytical Chemistry, 2005quem mais cita →
  15. 15I Apachitei, B Lonyuk, LE F-Apachitei e mais 2. Fatigue response of porous coated titanium biomedical alloys. Scripta Materialia, 2009quem mais cita →
  16. 16M. Niinomi. Fatigue characteristics of metallic biomaterials. International Journal of Fatigue, 2007quem mais cita →
  17. 17C Leinenbach e D. Eifler. Fatigue and cyclic deformation behaviour of surface-modified titanium alloys in simulated physiological media. Biomaterials, 2006quem mais cita →
  18. 18M Long e HJ. Rack. Titanium alloys in total joint replacement - a materials science perspective. Biomaterials, 1998quem mais cita →
  19. 19AL Yerokhin, X Nie, A Leyland e mais 2. Plasma electrolysis for surface engineering. Surface and Coatings Technology, 1999quem mais cita →
  20. 20CEB Marino, PAP Nascente, SR Biaggio e mais 2. XPS characterization of anodic titanium oxide films grown in phosphate buffer solutions. Thin Solid Films, 2004quem mais cita →
1–20 de 31 obras citadas

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

7 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações