  1. Refractive errors in children and adolescents in Bucaramanga (Colombia)

    Virgilio Galvis, Alejandro Tello, Johanna Otero e mais 3Arquivos Brasileiros de Oftalmologia2017citado por 1 artigo

    ABSTRACT Purpose: The aim of this study was to establish the frequency of refractive errors in children and adolescents aged between 8 and 17 years old, living in the metropolitan area of Bucaramanga (Colombia). Methods: This study was a secondary analysis of two descriptive cross-sectional studies that applied…

  2. Prevalence of refractive errors in students in Northeastern Brazil

    Carlos Alexandre de Amorim Garcia, Fernando Oréfice, Gabrielle Fernandes Dutra Nobre e mais 3Arquivos Brasileiros de Oftalmologia2005citado por 6 artigos

    PURPOSE: To determine the prevalence of refractive errors in the public and private school system in the city of Natal, Northeastern Brazil. METHODS: Refractometry was performed on both eyes of 1,024 randomly selected students, enrolled in the 2001 school year and the data were evaluated by the SPSS Data Editor 10.0…

  3. Prevalence of refractive errors in Möbius sequence

    Monica Fialho Cronemberger, Mariza Polati, Iara Debert e mais 6Arquivos Brasileiros de Oftalmologia2013

    PURPOSE: To assess the prevalence of refractive errors in Möbius sequence. METHODS: This study was carried out during the Annual Meeting of the Brazilian Möbius Society in November 2008. Forty-four patients diagnosed with the Möbius sequence were submitted to a comprehensive assessment, on the following specialties…

  4. Prevalence of refractive errors and ocular disorders in preschool and school children of Ibiporã - PR, Brazil (1989 to 1996)

    Rui Barroso Schimiti, Vital Paulino Costa, Maria José Ferreira Gregui e mais 2Arquivos Brasileiros de Oftalmologia2001citado por 14 artigos

    Purpose: To establish the prevalence of refractive errors and ocular disorders in preschool and schoolchildren of Ibiporã, Brazil. Methods: A survey of 6 to 12-year-old children from public and private elementary schools was carried out in Ibiporã between 1989 and 1996. Visual acuity measurements were performed by…

  5. Comparison of the refractive prediction errors of artificial intelligence formula with 3 conventional formulas and 11 combination methods in cataract surgery on eyes with short axial length

    Song-A Che, Mincheol Seong, Kookyoung Kim e mais 1Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: To compare the refractive prediction error of Hill-radial basis function 3.0 with those of 3 conventional formulas and 11 combination methods in eyes with short axial lengths. Methods: The refractive prediction error was calculated using 4 formulas (Hoffer Q, SRK-T, Haigis, and Hill-RBF) and 11…

  6. Vertex distance variability of the Vision-S™ 700 refractors in normal population

    Alexandre Costa Neto, Jaime Guedes, Denisse J. Mora-Paez e mais 6Revista Brasileira de Oftalmologia2024

    ABSTRACT Objective: To study vertex-optical distance variation and estimate its impact on manifest refraction. Methods: Prospective study in a private clinic using the Vision-S™ 700 with five forehead positions. Forehead on the third position showed the closest vertex-optical distance of 12mm. Results: Analysis of 52…

  7. Clinical evaluation of reprocessed blades in LASIK

    Felipe Mallmann, Celina Murata, Ester Sakae Yamazaki e mais 1Arquivos Brasileiros de Oftalmologia2008

    PURPOSE: To evaluate outcome and complications in LASIK with reprocessed blades. METHODS: Retrospective analysis of patients' charts submitted to complete custom LASIK from January 2004 to June 2005. Inclusion criteria comprised surgical description of blade use and minimum follow-up of 1 month. The blade was…

  8. Refractive error blindness

    Rakhi Dandona e Lalit DandonaBulletin of the World Health Organization2001citado por 10 artigos

    Recent data suggest that a large number of people are blind in different parts of the world due to high refractive error because they are not using appropriate refractive correction. Refractive error as a cause of blindness has been recognized only recently with the increasing use of presenting visual acuity for…

  9. Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes

    Maria A. Henriquez, Samuel-Arba Mosquera, Jorge Camargo e mais 1Arquivos Brasileiros de Oftalmologia2022

    ABSTRACT Purpose: To evaluate the vision quality by measuring the objective light scatter index and objective optical quality parameters (Strehl Ratio and Modulation Transfer Function) in patients with emmetropia and ametropia. Methods: This prospective, cross-sectional study included 408 eyes. The ametropic group…

  10. Reasons not to select patients for corneal refractive surgery

    André Luiz Parolin Ribeiro, Paulo Schor, Norma Allemann e mais 2Arquivos Brasileiros de Oftalmologia2002

    Purpose: To present how the section of Refractive Surgery of the Federal University of São Paulo assesses the candidates and the reasons to indicate for corneal refractive surgery. Methods: We examined 1626 patients. Anamnesis, complete ophthalmologic examination and corneal topography were performed in all patients…

  11. Prevalence of refractive error and spectacle coverage in schoolchildren in two urban areas of Chile

    Fernando Barria, Francisco Conte, Sergio Muñoz e mais 2Revista Panamericana de Salud Pública2018

    ABSTRACT Objective. To assess the impact of efforts to reduce visual impairment by detecting and treating refractive errors (REs) among schoolchildren in two urban areas of Chile. Methods. In 2013, in the communities of Concepción and La Florida, we conducted a multicenter, multistage-sampling, cross-sectional study…

  12. Myopia control strategies: a survey of Brazilian ophthalmologists

    Raíra Fortuna Cavaliere Mendes Moraes, Carolina Pelegrini Barbosa Gracitelli, Célia Regina Nakanami e mais 1Arquivos Brasileiros de Oftalmologia2026

    ABSTRACT Purpose: This study aimed to identify the strategies adopted by Brazilian ophthalmologists to control myopia in clinical practice. Methods: This was a prospective cross-sectional study. Data were collected using an online questionnaire. Results: Responses from 148 participants were collected between March and…

  13. Ophthalmologic manifestations in children with autism spectrum disorder

    Lucía Pereira, Ivana Ormazábal, Geraldine Kohn e mais 3Arquivos Brasileiros de Oftalmologia2026

    ABSTRACT Purpose: To determine the frequency and clinical characteristics of ophthalmologic manifestations in children aged ≤16 years with autism spectrum disorder who were evaluated at a private academic healthcare network and a public tertiary hospital. Methods: This retrospective descriptive study was conducted…

  14. Prevalence of myopic eyes in private practice and public care services in Brazil: 11 years of retrospective analysis

    André A. Homsi Jorge, Harley E. A. Bicas, Bruno Henrique Silva e mais 4Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: This study aimed to examine the prevalence of myopic eyes over 11 years (2008-2018) in a private clinic and a public assistance service. Methods: We retrospectively evaluated 6332 individuals (12,664 eyes) between 5 and 25 years old, seen at a private clinic-CEMO (2,663 individuals) and a public…

  15. Impact of screen use on tear breakup time: associations with ophthalmological factors and break frequency in office workers

    Berire Şeyma Durmuş Ece e İremnur AltındaşArquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: To examine how ophthalmological features, screen exposure duration, and break habits among office employees affect ocular surface parameters. Methods: This single-center cross-sectional study involved two assessments on the same day: one before and one after a visual display terminal task. During the…

  16. Longitudinal evaluation of corneal stability and tear film changes in first-time soft-contact lens wearers

    Neşe Arslan, Şule Barman Kakil, Bahar Aydoğdu e mais 1Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: Using advanced imaging techniques, this study aimed to evaluate corneal stability, epithelial remodeling, and tear film changes over a one-year period in first-time soft-contact lens wearers. Methods: A retrospective study was conducted on 100 eyes of 50 first-time daily soft-contact lens users aged…

  17. Comparison of refractometric measurements obtained with a portable autorefractor and conventional methods of refraction in schoolchildren

    Juliana Albano de Guimarães, Nilza Minguini e Keila Miriam Monteiro de CarvalhoRevista Brasileira de Oftalmologia2024

    ABSTRACT Objective: To assess the performance of a portable autorefractor as refractor and screening tool for refractive errors in schoolchildren. Methods: Cross-sectional observational study. Refractometric measurements of children between 5 and 10 years old were obtained through four methods: 2WIN under…

  18. Biometric error analysis after cataract surgery performed by residents, in patients with high myopia with SRK/T formula and Wang-Koch formula adjustment

    André Beckencamp, Bernardo Kaplan Moscovici, Daniel Diniz da Gama e mais 6Revista Brasileira de Oftalmologia2024citado por 3 artigos

    ABSTRACT Objective To evaluate intraocular lens power calculation and postoperative refractive errors in patients with high myopia undergoing cataract surgery, comparing predicted target refraction and actual postoperative refraction measured 30 days after surgery with SRK/T formula. Methods This retrospective…

  19. Clinical correlation between automated vision screening under cycloplegia and retinoscopy in young children

    Adriana Geremias, Nathalia Perussi Garcia, Caio Amadeo Silva Moreira e mais 2Arquivos Brasileiros de Oftalmologia2023

    ABSTRACT Purpose: To evaluate the clinical performance of the Spot Vision Screener and establish clinical correlations between automated screening and retinoscopy following induction of cycloplegia in preverbal children. Methods: In this prospective, cross-sectional study, children aged 6-36 months were evaluated…

  20. Vision screening using a smartphone platform

    Iara Debert, Douglas Rodrigues da Costa, Mariza Polati e mais 2Revista Paulista de Pediatria2022

    ABSTRACT Objective: The main aim of this study was to evaluate the performance of a platform designed for pediatricians to screen amblyopia using a smartphone. Methods: The medical records of consecutive children who received visual screening using a smartphone platform were retrospectively reviewed. The smartphone…