Arquivos Brasileiros de Oftalmologia2022

Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes

Maria A. Henriquez, Samuel-Arba Mosquera, Jorge Camargo e Luis Izquierdo Jr.

em inglês

cita 21 obras

resumo

ABSTRACT Purpose: To evaluate the vision quality by measuring the objective light scatter index and objective optical quality parameters (Strehl Ratio and Modulation Transfer Function) in patients with emmetropia and ametropia. Methods: This prospective, cross-sectional study included 408 eyes. The ametropic group comprised of eyes with best-corrected visual acuity of 0.0 logMAR or better and present at least a refractive error of ≥0.25 D. Patients underwent slit lamp examination, visual acuity, refraction, and vision quality using the HD Analyzer. Results: The mean objective light scatter indices were 0.62 ± 0.63, 0.77 ± 0.70, 0.74 ± 0.30, 0.93 ± 0.55, and 0.85 ± 0.61, and mean Strehl Ratio and Modulation Transfer Function scores were 38.17 ± 10.4, 37.37 ± 10.06, 29.84 ± 9.71, 33.2 ± 12.11, and 33.13 ± 10.09 in emmetropes, myopia, hyperopia, spherical equivalent of ≥0, and spherical equivalent of <0, respectively. Differences in all variables were significant between emmetropic and corrected hyperopic and between spherical equivalent of ≥0, and spherical equivalent of <0 eyes (p<0.05). Conclusion: In spectacle-corrected conditions (with trial frames), emmetropic and simple myopic eyes had significantly better vision quality compared to hyperopic and astigmatic eyes. The clinical significance of these results should be investigated in further studies.

como citar · ABNT NBR 6023

HENRIQUEZ, Maria A. et al. Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes. Arquivos Brasileiros de Oftalmologia, 2022. DOI: 10.5935/0004-2749.20220050.

Referências

21 obras citadas

  1. 1DO Mutti, GL Mitchell, LA Jones e mais 3. Axial growth and changes in lenticular and corneal power during emmetropization in infants. Invest Ophthalmol Vis Sci, 2005quem mais cita →
  2. 2G Westheimer. Image quality in the human eye. Opt Acta (Lond), 1970quem mais cita →
  3. 3IL Bailey e JE Lovie. New design principles for visual acuity letter charts. Am J Optom Physiol Opt, 1976quem mais cita →
  4. 4A Cerviño, SL Hosking, R Montes-Mico e mais 1. Clinical ocular wavefront analyzers. J Refract Surg, 2007quem mais cita →
  5. 5FL Ferris, A Kassoff, GH Bresnick e mais 1. New visual acuity charts for clinical research. Am J Ophthalmol, 1982quem mais cita →
  6. 6E Logean, E Dalimier e C Dainty. Measured double-pass intensity point-spread function after adaptive optics correction of ocular aberrations. Opt Express, 2008quem mais cita →
  7. 7JL Güell, J Pujol, M Arjona e mais 2. Optical quality analysis system; instrument for objective clinical evaluation of ocular optical quality. J Cataract Refract Surg, 2004quem mais cita →
  8. 8F Díaz-Doutón, A Benito, J Pujol e mais 3. Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument. Invest Ophthalmol Vis Sci, 2006quem mais cita →
  9. 9B Cochener, SR Patel e F Galliot. Correlational analysis of objective and subjective measures of cataract quantification. J Refract Surg, 2016quem mais cita →
  10. 10C Garrido, G Cardona, JL Güell e mais 1. Visual outcome of penetrating keratoplasty, deep anterior lamellar keratoplasty and Descemet membrane endothelial keratoplasty. J Optom, 2018quem mais cita →
  11. 11M Zhang, Q Jing, J Chen e mais 1. Analysis of corneal higher-order aberrations in cataract patients with high myopia. J Cataract Refract Surg, 2018quem mais cita →
  12. 12K Kamiya, K Shimizu, A Igarashi e mais 1. Time course of optical quality and intraocular scattering after refractive lenticule extraction. PLoS One [Internet], 2013quem mais cita →
  13. 13P Artal, A Benito, GM Pérez e mais 3. An objective scatter index based on double-pass retinal images of a point source to classify cataracts. PLoS One [Internet], 2011quem mais cita →
  14. 14K Kamiya, K Umeda, H Kobashi e mais 3. Effect of aging on optical quality and intraocular scattering using the double-pass instrument. Curr Eye Res, 2012quem mais cita →
  15. 15A Guirao, C González, M Redondo e mais 3. Average optical performance of the human eye as a function of age in a normal population. Invest Ophthalmol Vis Sci, 1999quem mais cita →
  16. 16JL Güell, J Pujol, M Arjona e mais 2. Optical Quality Analysis System; instrument for objective clinical evaluation of ocular optical quality. J Cataract Refract Surg, 2004quem mais cita →
  17. 17EA Villegas, E Alcón e P Artal. Optical quality of the eye in subjects with normal and excellent visual acuity. Invest Ophthalmol Vis Sci, 2008quem mais cita →
  18. 18MY Peng, S Hannan, D Teenan e mais 2. Monovision LASIK in emmetropic presbyopic patients. Clin Ophthalmol [Internet], 2018quem mais cita →
  19. 19LG Carney. Is the quality of vision with contact lenses adequate? Not only adequate but often superior. Cornea, 1990quem mais cita →
  20. 20F Díaz-Doutón, A Benito, J Pujol e mais 3. Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument. Invest Ophthalmol Vis Sci, 2006quem mais cita →
1–20 de 21 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações