resumo

PURPOSE: To evaluate the differences of wavefront aberrations under cycloplegic, scotopic and photopic conditions. METHODS: A total of 174 eyes of 105 patients were measured using the wavefront sensor (WaveScan® 3.62) under different pupil conditions: cycloplegic 8.58 ± 0.54 mm (6.4 mm - 9.5 mm), scotopic 7.53 ± 0.69 mm (5.7 mm - 9.1 mm) and photopic 6.08 ± 1.14 mm (4.1 mm - 8.8 mm). The pupil diameter, standard Zernike coefficients, root mean square of higher-order aberrations and dominant aberrations were compared between cycloplegic and scotopic conditions, and between scotopic and photopic conditions. RESULTS: The pupil diameter was 7.53 ± 0.69 mm under the scotopic condition, which reached the requirement of about 6.5 mm optical zone design in the wavefront-guided surgery and prevented measurement error due to the pupil centroid shift caused by mydriatics. Pharmacological pupil dilation induced increase of standard Zernike coefficients Z3-3, Z4(0) and Z5-5. The higher-order aberrations, third-order aberration, fourth-order aberration, fifth-order aberration, sixth-order aberration, and spherical aberration increased statistically significantly, compared to the scotopic condition (P<0.010). When the scotopic condition shifted to the photopic condition, the standard Zernike coefficients Z4(0), Z4², Z6-4, Z6-2, Z6² decreased and all the higher-order aberrations decreased statistically significantly (P<0.010), demonstrating that accommodative miosis can significantly improve vision under the photopic condition. Under the three conditions, the vertical coma aberration appears the most frequently within the dominant aberrations without significant effect by pupil size variance, and the proportion of spherical aberrations decreased with the decrease of the pupil size. CONCLUSIONS: The wavefront aberrations are significantly different under cycloplegic, scotopic and photopic conditions. Using the wavefront sensor (VISX WaveScan) to measure scotopic wavefront aberrations is feasible for the wavefront-guided refractive surgery.

como citar · ABNT NBR 6023

FAN, Rong et al. Comparison of wavefront aberrations under cycloplegic, scotopic and photopic conditions using WaveScan. Arquivos Brasileiros de Oftalmologia, 2012. DOI: 10.1590/S0004-27492012000200009.

Referências

29 obras citadas

  1. 1RJ Duffey e D Leaming. US trends in refractive surgery: 2004 ISRS/AAO Survey. J Refract Surg, 2005quem mais cita →
  2. 2DS Kim, J Narvaez, J Krassin e mais 1. Comparison of the VISX wavescan and NIDEK OPD-scan aberrometers. J Refract Surg, 2009quem mais cita →
  3. 3A Carkeet, S Velaedan, YK Tan e mais 2. Higher order ocular aberrations after cycloplegic and non-cycloplegic pupil dilation. J Refract Surg, 2003quem mais cita →
  4. 4P Artal, L Chen, EJ Fernandez e mais 3. Neural compensation for the eye's optical aberrations. J Vis, 2004quem mais cita →
  5. 5JJ Rozema, DE Van Dyck e MJ Tassignon. Clinical comparison of 6 aberrometers: Part 2: statistical comparison in a test group. J Cataract Refract Surg, 2006quem mais cita →
  6. 6RH Wei, L Lim, WK Chan e mais 1. Higher order ocular aberrations in eyes with myopia in a Chinese population. J Refract Surg, 2006quem mais cita →
  7. 7AZ Burakgazi, B Tinio, A Bababyan e mais 2. Higher order aberrations in normal eyes measured with three different aberrometers. J Refract Surg, 2006quem mais cita →
  8. 8CL Liang, SH Juo e CJ Chang. Comparison of higher-order wavefront aberrations with 3 aberrometers. J Cataract Refract Surg, 2005quem mais cita →
  9. 9KA Tuan, S Somani e DA Chernyak. Changes in wavefront aberration with pharmaceutical dilating agents. J Refract Surg, 2005quem mais cita →
  10. 10Y Wang, K Zhao, Y Jin e mais 2. Changes of higher order aberration with various pupil sizes in the myopic eye. J Refract Surg, 2003quem mais cita →
  11. 11MR Jankov 2nd, HP Iseli, M Bueeler e mais 3. The effect of phenylephrine and cyclopentolate on objective wavefront measurements. J Refract Surg, 2006quem mais cita →
  12. 12L Wang e DD Koch. Ocular higher-order aberrations in individuals screened for refractive surgery. J Cataract Refract Surg, 2003quem mais cita →
  13. 13ST Awwad, M El-Kateb e JP McCulley. Comparative higher-order aberration measurement of the LADARWave and Visx WaveScan aberrometers at varying pupil sizes and after pharmacologic dilation and cycloplegia. J Cataract Refract Surg, 2006quem mais cita →
  14. 14L Wang, RM Santaella, M Booth e mais 1. Higher-order aberrations from the internal optics of the eye. J Cataract Refract Surg, 2005quem mais cita →
  15. 15C McAlinden e JE Moore. Higher order aberrations using the NIDEK OPD-Scan and AMO WaveScan. J Refract Surg, 2010quem mais cita →
  16. 16G Walsh. The effect of mydriasis on the pupillary centration of the human eye. Ophthalmic Physiol Opt, 1988quem mais cita →
  17. 17Y Yang, K Thompson e SA Burns. Pupil location under mesopic, photopic, and pharmacologically dilated conditions. Invest Ophthalmol Vis Sci, 2002quem mais cita →
  18. 18J Tabernero, DA Atchison e EL Markwell. Aberrations and pupil location under corneal topography and Hartmann-Shack illumination conditions. Invest Ophthalmol Vis Sci, 2009quem mais cita →
  19. 19SS Wickremasinghe, GT Smith e JD Stevens. Comparison of dynamic digital pupillometry and static measurements of pupil size in determining scotopic pupil size before refractive surgery. J Cataract Refract Surg, 2005quem mais cita →
  20. 20S MacRae, J Schwiegerling e RW Snyder. Customized and low spherical aberration corneal ablation design. J Refract Surg, 1999quem mais cita →
1–20 de 29 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações