  1. Optimization of flight parameters for gamma radiation detection and mapping using drones

    F. Mamed, A. Vaz, A. Machado e mais 8Brazilian Journal of Radiation Sciences2025

    The application of drones in radiometric surveys has emerged as a promising solution, particularly for mapping radiation in areas that are difficult to access. This approach enables the creation of detailed distribution maps. However, the accuracy of the results is strongly influenced by the chosen flight strategy…

  2. Ionizing radiation-induced DNA injury and damage detection in patients with breast cancer

    Gissela Borrego-Soto, Rocío Ortiz-López e Augusto Rojas-MartínezGenetics and Molecular Biology2015

    Abstract Breast cancer is the most common malignancy in women. Radiotherapy is frequently used in patients with breast cancer, but some patients may be more susceptible to ionizing radiation, and increased exposure to radiation sources may be associated to radiation adverse events. This susceptibility may be related…

  3. Digital system to characterize solid state nuclear track detectors

    F. Pugliesi, V. Sciani, M.A. Stanojev Pereira e mais 1Brazilian Journal of Physics2007

    A digital system to characterize solid state nuclear track detectors(SSNTD) has been developed. It was used in the study of two detectors and its performance evaluated by comparing the obtained results with those determined by using an analog system, already in use for such purpose. The comparison of the results…

  4. Detection of Cosmic Radiation at Low Doses: Integrative Review of Biodosimetric Methodologies with Proposition of Aerospace Evaluation Index

    P. S. Abreu Junior, R. F. Soares, T. S. Costa e mais 4Brazilian Journal of Radiation Sciences2025

    Galactic cosmic radiation (GCR) is the major risk in long-duration spaceflight when considering biological damage. Hence, monitoring the absorbed dose is required and biodosimetry will be considered an important tool especially in scenarios where physical dosimetry does not work. This integrative review tries to find…

  5. Progress in the Design of New Gas-Based Neutron Detectors: A Critical Review

    D. Kreusch Filho, L. L. Caetano, A. M. Azevedo e mais 1Brazilian Journal of Radiation Sciences2025

    Abstract The detection of neutrons through gas detectors has been an established practice for decades, with significant applications in nuclear reactors and monitoring by international organizations responsible for safeguarding the use of nuclear energy. Historically, these detectors utilized Helium-3 (He-3) as the…

  6. Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors

    José Eduardo Manzoli, Vicente de Paulo de Campos e Mirian Saori DoiBrazilian Archives of Biology and Technology2006

    Measurement response of thermoluminescent dosimeter, TLD, used by workers or placed at positions where gamma radiation field could be in action affecting biological tissues, should be completely characterized, in order to achieve the radiation quantity with precision and confidence. Among the evaluations concerned to…

  7. Computer-aided diagnosis system versus conventional reading system in low-dose (< 2 mSv) computed tomography: comparative study for patients at risk of lung cancer

    Dong Wang, Lina Cao e Boya LiSao Paulo Medical Journal2023

    ABSTRACT BACKGROUND: Computer-aided diagnosis in low-dose (≤ 3 mSv) computed tomography (CT) is a potential screening tool for lung nodules, with quality interpretation and less inter-observer variability among readers. Therefore, we aimed to determine the screening potential of CT using a radiation dose that does not…

  8. Computer-aided diagnosis system versus conventional reading system in low-dose (< 2 mSv) computed tomography: comparative study for patients at risk of lung cancer

    Dong Wang, Lina Cao e Boya LiSao Paulo Medical Journal2022

    ABSTRACT BACKGROUND: Computer-aided diagnosis in low-dose (≤ 3 mSv) computed tomography (CT) is a potential screening tool for lung nodules, with quality interpretation and less inter-observer variability among readers. Therefore, we aimed to determine the screening potential of CT using a radiation dose that does not…

  9. Estimating 131I biokinetics and radiation doses to the red marrow and whole body in thyroid cancer patients: probe detection versus image quantification

    José Willegaignon, Rogério Alexandre Pelissoni, Beatriz Christine de Godoy Diniz Lima e mais 4Radiologia Brasileira2016

    Abstract Objective: To compare the probe detection method with the image quantification method when estimating 131I biokinetics and radiation doses to the red marrow and whole body in the treatment of thyroid cancer patients. Materials and Methods: Fourteen patients with metastatic thyroid cancer, without metastatic…

  10. Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis

    Márcio Luís Duarte, Lucas Ribeiro dos Santos, Acary Souza Bulle Oliveira e mais 2Sao Paulo Medical Journal2021

    BACKGROUND: Computed tomography (CT) accounts for 13% of all radiological examinations in the United States and 40-70% of the radiation that patients receive. Even with the advent of magnetic resonance imaging (MRI), CT continues to be the gold standard for diagnosing bone fractures. There is uncertainty as to whether…

  11. In vivo monitoring in radiological or nuclear emergencies: a program for intercomparison of detection efficiency in NaI(Tl) portable detectors

    Alexandre B. Soares, José U. Delgado, Alfredo Lopes Ferreira Filho e mais 1Brazilian Journal of Radiation Sciences2025

    In vivo internal monitoring is a laboratory technique used to assess and quantify the incorporation of radionuclides in the human body. Demand for such services may increase significantly in a radiological or nuclear emergency. In addition to dedicated laboratories, researchers have proposed the calibration of…

  12. Pyroelectric composite film for X-ray intensity detection

    Walter Katsumi Sakamoto, Giuliano Pierre Estevam, Aparecido Augusto de Carvalho e mais 2Materials Research2012

    Composite material obtained with modified lead titanate (Pz34) ferroelectric ceramic and polyether-ether-ketone (PEEK) polymer matrix was used as sensitive component to measure X-ray intensity in a novel detection system. The sensing element works as a thermal transducer, converting a non-quantified thermal flux into…

  13. Role of tube current variation and metal artifact reduction tool in CBCT for detection of missing MB2 canal

    Caio Alencar-Palha, Marcyele Natane da Silva Morais, Fernanda Bulhões Fagundes e mais 3Brazilian Dental Journal2025

    Abstract We aimed to evaluate the effect of varying the tube current and the Metal Artifact Reduction (MAR) tool on the detection of the missing second mesiobuccal (MB2) canal. Forty maxillary molars (20 with and 20 without MB2) were selected and confirmed by micro-CT. The teeth underwent endodontic preparation, with…

  14. The effect of different exposure parameters on proximal caries detection using the Kodak 9000 3D CBCT system

    Amanda Katarinny Goes GONZAGA, Larissa Rangel PEIXOTO, Luciana Soares de Andrade Freitas OLIVEIRA e mais 3RGO - Revista Gaúcha de Odontologia2017

    ABSTRACT Objective: The objective of study was to evaluate the diagnostic quality of CBCT images for caries lesions detection using different exposure parameters. Methods: Sixty extracted human teeth were selected and scanned using Kodak 9000 3D CBCT system, with the following exposure parameters combinations: 74 kV…

  15. Evaluation of Synthesized 2D Mammography Combined with Tomosynthesis: A Potential Approach to Reduce Radiation Exposure in Breast Cancer Diagnostic Exams

    Paula Medina Maciel Gomes Curi Bonotto, Léonie Marie Catherine Lefebvre, Carlos Frederico Motta Vasconcelos e mais 3Revista Brasileira de Cancerologia2026

    ABSTRACT Introduction: Breast cancer is the most common globally among the female population. Conventional 2D Full-Field Digital Mammography (FFDM) is the standard screening tool but limited in dense breasts. Digital Breast Tomosynthesis (DBT) reduces this limitation, especially in extremely dense and heterogeneously…

  16. Practical leak detection and leak rate measurement applied to a hot cell for radiopharmaceuticals preparations in a GMP compliant Laboratory

    Rodrigo da Silveira Santos, Carlos Leonel Zapparoli, Joel Mendes dos Santos e mais 3Brazilian Journal of Radiation Sciences2026

    Abstract Hot cells are containment systems used in radiopharmaceutical production, designed to ensure radiation protection and product quality. Leak tightness testing is a mandatory requirement under CNEN NN 6.13 standard, as it directly impacts worker safety, environmental protection, and product integrity. This…