RGO - Revista Gaúcha de Odontologia2017
The effect of different exposure parameters on proximal caries detection using the Kodak 9000 3D CBCT system
Amanda Katarinny Goes GONZAGA, Larissa Rangel PEIXOTO, Luciana Soares de Andrade Freitas OLIVEIRA, Saulo Leonardo Sousa MELO, Paulo Sérgio Flores CAMPOS e Daniela Pita de MELO
em inglês
resumo
ABSTRACT Objective: The objective of study was to evaluate the diagnostic quality of CBCT images for caries lesions detection using different exposure parameters. Methods: Sixty extracted human teeth were selected and scanned using Kodak 9000 3D CBCT system, with the following exposure parameters combinations: 74 kV, 10mA; 74 kV, 12mA; 74 kV, 8 mA; 70 kV, 10 mA; 70kV, 12 mA; 70 kV e 8 mA; 70 kV, 6.3 mA. Two observers evaluated the images for caries presence using CS 3D Imaging Software. Each observer scored the proximal surfaces of each tooth on a 5-point scale. The scores were compared to histological sections used as gold standard. Accuracy for caries lesion detection was assessed for each exposure parameter combination and evaluated by means of ROC curve analysis. Results: The mean values for the areas under the ROC curves for each exposure parameter combination varied from 0.35 to 0.60. There was no statistical significant difference among protocols 1, 2, 4, 6 and 7. However, protocols 3 and 5 differed from all protocols. Conclusion: Although the highest dose protocol was the most efficient for proximal caries detection, the lowest dose protocol should be chosen based on the ALADA principle.
como citar · ABNT NBR 6023
GONZAGA, Amanda Katarinny Goes et al. The effect of different exposure parameters on proximal caries detection using the Kodak 9000 3D CBCT system. RGO - Revista Gaúcha de Odontologia, 2017. DOI: 10.1590/1981-863720170002000053256.
Referências
22 obras citadas
- 1FF Demarco, MB Corrêa, MS Cenci e mais 2. Longevity of posterior composite restorations not only a matter of materials. Dent Mater, 2012quem mais cita →
- 2VV Gordan, JL Riley, RM Carvalho e mais 3. Methods used by dental practice-based research network (DPBRN) dentists to diagnose dental caries. Oper Dent, 2011quem mais cita →
- 3A Charuakkra, S Prapayasatok, A Janhom e mais 3. Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries. Imaging Sci Dent, 2011quem mais cita →
- 4DI Kim, UY Lee, SO Park e mais 2. Identification using frontal sinus by three-dimensional reconstruction from computed tomography. J Forensic Sci, 2013quem mais cita →
- 5S Rathore, D Tyndall, J Wright e mais 1. Ex vivo comparison of Galileos cone beam CT and intraoral radiographs in detecting occlusal caries. Dentomaxillofac Radiol, 2012quem mais cita →
- 6A Wenzel, E Hirsch, J Christensen e mais 3. Detection of cavitated approximal surfaces using cone beam CT and intraoral receptors. Dentomaxillofac Radiol, 2013quem mais cita →
- 7S Murat, K Kamburoglu, A Isayev e mais 2. Visibility of artificial buccal recurrent caries under restorations using different radiographic techniques. Oper Dent, 2013quem mais cita →
- 8D Jones, F Mannocci, M Andiappan e mais 2. The effect of alteration of the exposure parameters of a cone-beam computed tomographic scan on the diagnosis of simulated horizontal root fractures. J Endod, 2015quem mais cita →
- 9FM Jadu, ML Hill, MJ Yaffe e mais 1. Optimization of exposure parameters for cone beam computed tomography sialography. Dento Maxillofac Radiol, 2011quem mais cita →
- 10PP Jaju e SP Jaju. Cone-beam computed tomography Time to move from ALARA to ALADA. Imaging Sci Dent, 2015quem mais cita →
- 11S Valizadeh, MA Tavakkoli, H Karimi Vasigh e mais 2. Evaluation of cone beam computed tomography (CBCT) system comparison with intraoral periapical radiography in proximal caries detection. J Dent Res Dent Clin Dent Prospects, 2012quem mais cita →
- 12BG Akdeniz, HG Gröndahl e B Magnusson. Accuracy of proximal caries depth measurements comparison between limited cone beam computed tomography, storage phosphor and film radiography. Caries Res, 2006quem mais cita →
- 13D Maret, N Telmon, OA Peters e mais 3. Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT. Dentomaxillofac Radiol, 2012quem mais cita →
- 14M Moshfeghi, MA Tavakoli, ET Hosseini e mais 2. Analysis of linear measurement accuracy obtained by cone beam computed tomography (CBCT-NewTom VG). Dent Res J, 2012quem mais cita →
- 15MGG Torres, PSF Campos, NPN Segundo e mais 3. Evaluation of referential dosages obtained by Cone-Beam Computed Tomography examinations acquired with different voxel sizes. Dental Press J Orthod, 2010quem mais cita →
- 16JB Ludlow e M Ivanovic. Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2008quem mais cita →
- 17F Haiter-Neto, A Wenzel e E Gotfredsen. Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dento Maxillofac Radiol, 2008quem mais cita →
- 18SM Young, JT Lee, RJ Hodges e mais 3. A comparative study of high-resolution cone beam computed tomography and charge-coupled device sensors for detecting caries. Dentomaxillofac Radiol, 2009quem mais cita →
- 19ZL Zhang, XM Qu, G Li e mais 2. The detection accuracies for proximal caries by cone-beam computerized tomography, film, and phosphor plates. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2011quem mais cita →
- 20X Qu, G Li, Z Zhang e mais 1. Detection accuracy of in vitro approximal caries by cone beam computed tomography images. Eur J Radiol, 2011quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda