acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Pull technique”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. A safe "cut, tie and thread-pull" method for percutaneous endoscopic gastrostomy tube removal in children with congenital craniofacial anomalies and pharyngeal stenosis

    Adam Hermanowicz, Ewa Matuszczak, Katarzyna Kondej-Muszynska e mais 3Nutrición Hospitalaria2014

    Percutaneous endoscopic gastrostomy (PEG) is a widely used method for tube feeding with enteral nutrition. Both PEG´s insertion and PEG´s removal are usually easy and uncomplicated. The latter can be, however, of substantial difficulty in children with distorted anatomy, such as pharyngeal stenosis or endured…

  2. Minimally Invasive Suture Technique Pull-out to Repair the Acute Flexor Tendons in Zone II of the Hand

    João Carlos Belloti, Luis Antonio Buendia, Marcel Jun Tamaoki e mais 3Revista Brasileira de Ortopedia2024

    Abstract Objective: To evaluate the safety and effectiveness of a modified pull-out suture technique in patients undergoing primary repair surgery for injuries to the flexor tendons of the fingers with Total Active Motion (TAM) as the primary outcome. Method: A total of 29 patients (38 fingers) were chosen from both…

  3. Influence of Push and Pull Techniques on High-Speed Buried-Arc GMAW Process

    Natália Wendt Dreveck, Luiz Delagnelo Barbetta, Danielle Bond e mais 1Soldagem & Inspeção2020

    Abstract: The GMAW torch orientation, whether pulling or pushing, influences both arc welding and hybrid processes. In hybrid laser-arc welding, for example, when the torch is pulled, a greater bead penetration is obtained. To promote greater penetration, the literature also indicates the use of a buried arc in GMAW…

  4. Pullulan as a stabilizer agent of polymeric nanocapsules for drug delivery

    Janaíne Micheli Chassot, Luana Mota Ferreira, Felipe Pereira Gomes e mais 3Brazilian Journal of Pharmaceutical Sciences2016

    ABSTRACT Polymeric stabilizers have received attention in the preparation of nanostructured systems due to their ability to enhance formulation stability. Considering this, the objective of this work was to prepare poly(ε-caprolactone) nanocapsules using the pullulan as a polymeric stabilizer. The nanocapsules were…

  5. Continuous Modeling Technique of Fiber Pullout from a Cement Matrix with Different Interface Mechanical Properties Using Finite Element Program

    Leandro Ferreira Friedrich e Chong WangLatin American Journal of Solids and Structures2016citado por 2 artigos

    Abstract Fiber-matrix interface performance has a great influence on the mechanical properties of fiber reinforced composite. This influence is mainly presented during fiber pullout from the matrix. As fiber pullout process consists of fiber debonding stage and pullout stage which involve complex contact problem…

  6. Effects of different handle techniques during the back pull exercise on the angular kinematic and production of strength

    Luciano P. da Silva, Juliano Dal Pupo, Josiele V. Alves e mais 1Revista Portuguesa de Ciências do Desporto2007

    The present investigation aims to verify the kinematic pattern of movement in the back pull exercise through the evaluation of the articular angle of the joint of the elbow and shoulder between two different handle techniques in the bar: open and closed, considering the spans of the individuals. Furthermore, the…

  7. Effect of implant crestal position on primary stability before and after loading: an in vitro study

    Jessica Pires de CARVALHO, Umberto Demoner RAMOS, Luiz Gustavo de SOUSA e mais 4Revista de Odontologia da UNESP2022

    Abstract Introduction Primary stability is one of the goals of modern implant dentistry and if achieved, reduces treatment time for prosthetic rehabilitation and the number of interventions made in patients mouth. Several companies state as protocol for connical conection implants, a subcrestally positioning…

  8. Pull Off test to evaluate the compressive strength of concrete: an alternative to Brazilian standard techniques

    E. Pereira e M. H. F. de MedeirosRevista IBRACON de Estruturas e Materiais2012

    To estimate the compressive strength of concrete is necessary in many reinforced concrete structures inspection works. In Brazil, the standard tests for this purpose are: Compressive test in drilled cores, rebound hammer test and ultrasonic test. In the United States and Europe are also regulated other techniques. The…

  9. DIRECT PEDICLE SCREW INSERTION PULLOUT STRENGTH

    RÔMULO PEDROZA PINHEIRO, ARIANE ZAMARIOLI, THIBAULT CHANDANSON e mais 3Acta Ortopédica Brasileira2021

    ABSTRACT Objective: Study the in vitro pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw), a screw pedicle designed to be inserted using a direct insertion technique. Methods: DSG Screws of 5.5 mm and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF…

  10. A novel approach to lower rectal anastomosis: technique innovation and the preliminary report of twenty cases

    Abbas Alibakhshi, Yosra Jahangiri, Fereydoun Sirati e mais 4Journal of Coloproctology (Rio de Janeiro)2016

    Abstract Background and aims To describe a practical technique innovation (transanal ‘Pull-through’ approach) as a feasible, safe and effective alternative to the conventional transabdominal stapler low rectal anastomosis in lesions of minimal anatomical distinction from the adjacent intact mucosa. Material and…