acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Prosthesis Failure”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Symptomatic Aortic Paravalvular Leak: Percutaneous Treatment with Amplatzer Vascular Plug III Device as an Alternative to Surgery

    Gabriel E. Pérez Baztarrica, Gastón Heredia, Juan Arellano e mais 2Brazilian Journal of Cardiovascular Surgery2018

    Abstract A significant prosthetic paravalvular leak is an uncommon and severe postsurgical complication correlated to the occurrence of congestive heart failure and hemolytic anemia. Percutaneous treatment has become an attractive and effective proposal to relieve symptoms and reduce complications in patients whose…

  2. Evaluation of Polyethylene Wear in a Brazilian Ultracongruent Knee Prosthesis with a Rotating Platform

    José Ricardo Pécora e Valéria RomeroRevista Brasileira de Ortopedia2021citado por 1 artigo

    Abstract Objective To evaluate the wear of polyethylene in a Brazilian ultracongruent knee prosthesis with a rotating platform (Rotaflex, Víncula, Rio Claro, SP, Brasil). Methods We used the test method with the loading and preparation parameters mentioned in the standards regulation ISO 14243-1:2009, and the…

  3. Percutaneous Treatment of Mitral Paraprosthetic Regurgitation: an Alternative to Surgery

    Roney Orismar Sampaio, Alessandra Gomes de Oliveira, George Barreto Miranda e mais 3Arquivos Brasileiros de Cardiologia2015

    Paraprosthetic regurgitation occurs in approximately 7%–17% of patients undergoing mitral valve replacement and 2%–10% of patients undergoing aortic valve replacement1,2. Typically, this regurgitation is discrete and does imply major clinical complications; however, when it is moderate or severe, the consequences can…

  4. Failure of prosthetic screws on 971 implants

    Carolina Schäffer Morsch, Caroline Freitas Rafael, Juan Felipe Montero Dumes e mais 3Brazilian Journal of Oral Sciences2015

    Abstract Aim: To evaluate the presence of failures in prosthetic screws and whether these failures are related to the type of prosthesis, abutment angulation and presence or not of intermediate. Methods: Two-hundred and sixty-seven patients were evaluated at the Federal University of Santa Catarina, totaling 971…

  5. Clinical and radiographic outcomes of hip resurfacing arthroplasty after eight years - a retrospective study

    Felipe Spinelli Bessa, Ronald Delgadillo Fuentes, Helder de Souza Miyahara e mais 3Revista Brasileira de Ortopedia2018

    ABSTRACT Objective: To assess the clinical and radiographic outcomes of hip resurfacing arthroplasty for the treatment of hip osteoarthritis. Methods: This study retrospectively assessed 30 patients with hip osteoarthritis who underwent hip resurfacing arthroplasty between 2005 and 2014. Patients of both genders…

  6. Spontaneous extrusion of a Müller sphere 30 years after evisceration

    Camyla Lemos Budib, Jade Pinto de Queiroz Guerra, Bernardo Kaplan Moscovici e mais 3Revista Brasileira de Oftalmologia2026

    ABSTRACT We report a rare case of spontaneous extrusion of a Müller sphere implant three decades after ocular evisceration. A 44-year-old woman, with a history of evisceration of the left eye due to phthisis bulbi from congenital syphilis, presented with extrusion of an orbital implant. Surgical management consisted…

  7. SHORT-TERM EVALUATION BETWEEN POLYETHYLENE THICKNESS IN PRIMARY TOTAL KNEE ARTHROPLASTY

    Rodrigo Sattamini Pires e Albuquerque, Thales Ramos Pizziolo, Octavio Augusto Tome da Silva e mais 3Acta Ortopédica Brasileira2024

    ABSTRACT Objective: The objective of the research was to carry out a comparative study between Smith & Nephew ® or Zimmer ® prostheses with thick versus thin polyethylene, in patients undergoing primary total knee arthroplasty, during a short-term follow-up. Thus, the objective was to analyze the survival of the…

  8. Metallic artifact suppression with MAVRIC-SL in magnetic resonance imaging for assessing chronic pain after hip or knee arthroplasty

    Gustavo Mota Rios, Carolina Freitas Lins, Milson Carvalho Quadros Junior e mais 3Radiologia Brasileira2023

    Abstract Objective: To analyze the association between osteolysis at the prosthesis interfaces, as determined by magnetic resonance imaging (MRI) with multiacquisition variable-resonance image combination selective (MAVRIC-SL) sequences, and clinical severity after knee or hip arthroplasty, as well as to assess…

  9. Bone Integration and Prevalence of Radiolucent Lines around the Pegs of Minimally Cemented Glenoid Components in Total Shoulder Arthroplasty

    Márcio Schiefer, Gláucio Siqueira, Alan Figueira e mais 3Revista Brasileira de Ortopedia2022

    Abstract Objectives Glenoid component failure is the main cause of total shoulder arthroplasty (TSA) revision, and component design seems to influence the failure rate. The aim of the present study was to clinically and radiographically (through X-rays and computed tomography scan) evaluate the results of TSA using a…

  10. Evaluation of Removal Force in Prosthetic Components of Morse Taper Dental Implants

    Angelo Marcelo Tirado dos Santos, Glaykon Alex Vitti Stabile, Klissia Romero Felizardo e mais 5Brazilian Dental Journal2022

    Abstract The longevity of prosthetic rehabilitation is determined by the stability of the implant and abutment interfaces. True morse taper connections on dental restorations have been effective, however activation force still empirical. This work compared the activation strength and internal contact of Morse taper…

  11. METHOD FOR REMOVING BROKEN PROXIMAL FEMORAL NAILS USING EXISTING SCREW HOLE

    CHO HONG MAN e MIN WOONG BAEActa Ortopédica Brasileira2018

    ABSTRACT The use of intramedullary nailing to treat proximal femoral fractures has increased in recent years. Nail breakage is a rare complication of intramedullary nailing of the femur, and generally occurs at the non-united fracture site. Removal of the distal fragment of a broken nail is a challenging problem. In…

  12. Short implants versus longer implants with maxillary sinus lift. A systematic review and meta-analysis

    Ronaldo Silva CRUZ, Cleidiel Aparecido de Araújo LEMOS, Victor Eduardo de Souza BATISTA e mais 4Brazilian Oral Research2018citado por 1 artigo

    Abstract This study compared the survival rate of dental implants, amount of marginal bone loss, and rates of complications (biological and prosthetic) between short implants and long implants placed after maxillary sinus augmentation. This systematic review has been registered at PROSPERO under the number…

  13. Trocar-assisted intrascleral sutureless fixation of a dislocated three-piece sulcus intraocular lens

    Remzi Karadag, Bahar Gunes e Ahmet DemiorokArquivos Brasileiros de Oftalmologia2017

    ABSTRACT Trocar-assisted intraocular lens (IOL) reposition surgery using a scleral fixation method was performed for a patient with a dislocated sulcus IOL. Two 3-mm-long scleral tunnels 2 mm from and parallel to the limbus were formed using a 23-gauge vitrectomy trocar transconjunctivally entering the sclera at an…

  14. Advantages and limitations of national arthroplasty registries. The need for multicenter registries: the Rempro-SBQ

    Luiz Sérgio Marcelino Gomes, Milton Valdomiro Roos, Edmilson Takehiro Takata e mais 4Revista Brasileira de Ortopedia2017citado por 1 artigo

    Abstract While the value of national arthroplasty registries (NAR) for quality improvement in total hip arthroplasty (THA) has already been widely reported, some methodological limitations associated with observational epidemiological studies that may interfere with the assessment of safety and efficacy of prosthetic…

  15. Spontaneous dislocation of the polyethylene component following knee revision arthroplasty: case report

    Eduardo Zaniol Migon, Geraldo Luiz Schuck de Freitas, Marcos Wainberg Rodrigues e mais 3Revista Brasileira de Ortopedia2015

    Dislocation of the polyethylene component in knee arthroplasty is a rare complication. The main triggering factor is failure of the locking mechanism, which may result from technical errors of insertion, trauma or even implant failure. Here, a case of dislocation of the polyethylene component from the tibial base…

  16. Fracture resistance of endodontically treated teeth restored with different intraradicular posts with different lengths

    Jefferson Ricardo Pereira, Elias Manoel Ribeiro Neto, Saulo Pamato e mais 3Brazilian Journal of Oral Sciences2013

    AIM: This study compared the resistance to fracture of endodontically treated teeth restored with different intraradicular posts with different lengths and full coverage metallic crowns. METHODS: Sixty extracted human canine teeth were randomly divided into 6 groups. Groups CP5, CP75 and CP10 were restored using…

  17. Resistance of three implant-abutment interfaces to fatigue testing

    Cleide Gisele Ribeiro, Maria Luiza Cabral Maia, Susanne S. Scherrer e mais 2Journal of Applied Oral Science2011citado por 6 artigos

    The design and retentive properties of implant-abutment connectors affect the mechanical resistance of implants. A number of studies have been carried out to compare the efficacy of connecting mechanisms between abutment and fixture. Objectives: The aims of this study were: 1) to compare 3 implant-abutment interfaces…

  18. Transcatheter Valve-in-Valve Repositioning of CoreValve® Evolut™ Rin Aortic Prosthesis

    Ana Isabel Azevedo, Ricardo Ladeiras-Lopes, Alberto Rodrigues e mais 2Arquivos Brasileiros de Cardiologia2016

    A 41-year-old man with history of surgical replacement of the aortic valve with a 21mm-Mitroflow bioprosthesis (1A), presented with functional class IV heart failure. Transesophageal echocardiography confirmed severe bioprosthesis obstruction (1B). We implanted a 23mm-CoreValve® Evolut™ R (Medtronic, Minneapolis, USA)…

  19. Effect of restoration technique on stress distribution in extensively destroyed premolars: a finite element analysis study

    Wagner Araújo de NEGREIROS, Rômulo Rocha REGIS, Karina Matthes de Freitas PONTES e mais 2RGO - Revista Gaúcha de Odontologia2017

    ABSTRACT Objective: The objective of this study by the finite element method was to analyze the stress distribution on a single-rooted mandibular premolar tooth restored in two different ways. Methods: Laboratory simulation considered the following situations: 1) premolar restored with gold cast post and ceramic…

  20. Influence of anatomic reference on the buccal contour of prosthetic crowns

    Flávia Sabrina Queirós Vasconcelos, Ana Christina Claro Neves, Laís Regiane da Silva-Concílio e mais 2Brazilian Oral Research2009

    During clinical practice, when performing prosthetic rehabilitation with single crowns, improper reproduction of the dental contour by the dental laboratory is a common occurrence. Therefore, the present study evaluated the fidelity of the reproduction of the buccal contour in an upper left canine performed by three…