Acta Ortopédica Brasileira2024

SHORT-TERM EVALUATION BETWEEN POLYETHYLENE THICKNESS IN PRIMARY TOTAL KNEE ARTHROPLASTY

Rodrigo Sattamini Pires e Albuquerque, Thales Ramos Pizziolo, Octavio Augusto Tome da Silva, Marcelo Alfredo Guerra Monteiro, Sandra Tie Nishibe Minamoto e Alan de Paula Mozella

em inglês

cita 17 obras, 1 no acervo

resumo

ABSTRACT Objective: The objective of the research was to carry out a comparative study between Smith & Nephew ® or Zimmer ® prostheses with thick versus thin polyethylene, in patients undergoing primary total knee arthroplasty, during a short-term follow-up. Thus, the objective was to analyze the survival of the implants in question under the clinical and radiographic aspect. Methods: The sample was divided into two groups: Group 1 with thick polyethylene and group 2 with thin polyethylene. A clinical analysis of the patients was carried out and the implants were checked for loosening. Results: The groups were similar when compared. According to the Ahlbäck classification, 83% of the patients were in groups IV and V. The median functional score in the postoperative period was similar between the two groups. Postoperatively, the tibiofemoral angle fluctuated between 5 and 6 0 valgus on average. Two complications were observed in each group. None of the evaluated patients presented implant loosening Conclusion: Patients treated with thick polyethylene had the same functional score as the control group, as well as the absence of radiographic changes in this short-term follow-up, with implant survival and a similar rate of complications between both groups. Level of evidence III, Retrospective study.

como citar · ABNT NBR 6023

PIRES E ALBUQUERQUE, Rodrigo Sattamini et al. SHORT-TERM EVALUATION BETWEEN POLYETHYLENE THICKNESS IN PRIMARY TOTAL KNEE ARTHROPLASTY. Acta Ortopédica Brasileira, 2024. DOI: 10.1590/1413-785220243203E276755.

Referências

17 obras citadas · 1 no acervo

  1. 1E. Jämsen, P. Jäntti, T. Puolakka e mais 1. Primary knee replacement for primary osteoarthritis in the aged: gender differences in epidemiology and preoperative clinical state. Aging Clin Exp Res, 2012quem mais cita →
  2. 2M. C. Ferreira, J. C. P. Oliveira, F. F. Zidan e mais 3. Total knee and hip arthroplasty: the reality of assistance in Brazilian public health care. Rev Bras Ortop, 2018no acervo →
  3. 3J.R. Pécora e V. Romero. Avaliação do desgaste do polietileno de uma prótese de joelho nacional ultracongruente de base rotatória. Rev Bras Ortop, 2021quem mais cita →
  4. 4S. A. Edwards, H. G. Pandit, J. L. Ramos e mais 1. Analysis of polyethylene thickness of tibial components in total knee replacement. J Bone Joint Surg Am, 2002quem mais cita →
  5. 5M. S. Kuster e G. W. Stachowiak. Factors affecting polyethylene wear in total knee arthroplasty. Orthopedics, 2002quem mais cita →
  6. 6D. L. Bartel, V. L. Bicknell e T. M. Wright. The effect conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg Am, 1986quem mais cita →
  7. 7C. R. Schwartsmann, L. C. Boschin, M. S. Corrêa e mais 1. Análise da espessura do polietileno tibial usado nas artroplastias totais de joelho. Rev Bras Ortop, 2004quem mais cita →
  8. 8A. B. Weber e H. G. Morris. Thickness of tibial inserts in total knee arthroplasty. J Arthroplasty, 1996quem mais cita →
  9. 9M. E. Berend, P. J. Davis, M. A. Ritter e mais 3. Thicker” polyethylene bearings are associated with higher failure rates in primary total knee arthroplasty. J Arthroplasty, 2010quem mais cita →
  10. 10S. P. Garceau, Y. S. Warschawski, A. Tang e mais 3. The Effect of Polyethylene Liner Thickness on Patient Outcomes and Failure After Primary Total Knee Arthroplasty. J Arthroplasty, 2020quem mais cita →
  11. 11N. J. Greco, D. A. Crawford, K. R. Berend e mais 2. Thicker” polyethylene bearings are not associated with higher failure rates in primary total knee arthroplasty. J Arthroplasty, 2018quem mais cita →
  12. 12J. N. Insall, C. S. Ranawat, P. Aglietti e mais 1. A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg Am, 1976quem mais cita →
  13. 13R. M. Meneghini, M. A. Mont e D. B. Backstein. Development of a Modern Knee Society Radiographic Evaluation System and Methodology for Total Knee Arthroplasty. J Arthroplasty, 2015quem mais cita →
  14. 14G. W. Keyes, A. J. Carr, R. K. Miller e mais 1. The radiographic classification of medial gonarthrosis. Correlation with operation methods in 200 knees. Acta Orthop Scand, 1992quem mais cita →
  15. 15R. E. Leach, T. Gregg e F. J. Siber. Weight-bearing radiography in osteoarthritis of the knee. Radiology, 1970quem mais cita →
  16. 16G. Eknoyan. Adolphe Quetelet (1796-1874) – The average man and indices of obesity. Nephrol Dial Transplant, 2008quem mais cita →
  17. 17S. P. Garceau, Y. S. Warschawski, A. Tang e mais 3. The Effect of Polyethylene Liner Thickness on Patient Outcomes and Failure After Primary Total Knee Arthroplasty. J Arthroplasty, 2020quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações