acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Plasma monitoring”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Determining plasma morphine levels using GC-MS after solid phase extraction to monitor drug levels in the postoperative period

    Veronica Santos, Karin Jannet Vera López, Luciana Moraes Santos e mais 3Clinics2008

    OBJECTIVE: To implement a selective and sensitive analytical method to quantify morphine in small volumes of plasma by gas-liquid chromatography-mass spectrometry (GC-MS), aimed at post-operatively monitoring the drug. METHOD: A gas-liquid chromatographic method with mass detection has been developed to determine…

  2. Propranolol plasma monitoring in children submitted to surgery of tetralogy of Fallot by a micromethod using high performance liquid chromatography

    Cristina Sanches, Filomena R.B.G. Galas, Anne G.O. de M. Silva e mais 3Clinics2007

    OBJECTIVE: To evaluate the analytical micromethod using liquid chromatography for the quantification of propranolol in children submitted to surgery of tetralogy of Fallot (TLF). Methods: Only 0.2 mL of plasma is required for the assay. Peaks eluted at 8.4 (Propranolol) and 17.5 min (verapamil, internal standard) from…

  3. Pharmacokinetic-pharmacodynamic correlation of imipenem in pediatric burn patients using a bioanalytical liquid chromatographic method

    Silvia Regina Cavani Jorge Santos, Cristina Sanches-Giraud, Carlindo Vieira Silva Júnior e mais 1Brazilian Journal of Pharmaceutical Sciences2015

    A bioanalytical method was developed and applied to quantify the free imipenem concentrations for pharmacokinetics and PK/PD correlation studies of the dose adjustments required to maintain antimicrobial effectiveness in pediatric burn patients. A reverse-phase Supelcosil LC18 column (250 x 4.6 mm 5 micra), binary…

  4. Monitoring imatinib plasma concentrations in chronic myeloid leukemia

    Darlize Hübner Martins, Sandrine Comparsi Wagner, Tamyris Vianna dos Santos e mais 4Revista Brasileira de Hematologia e Hemoterapia2011citado por 2 artigos

    Imatinib has proved to be effective in the treatment of chronic myeloid leukemia, but plasma levels above 1,000 ng/mL must be achieved to optimize activity. Therapeutic drug monitoring of imatinib is useful for patients that do not present clinical response. There are several analytical methods to measure imatinib in…

  5. Standardization method for measurement of hydroxyurea by Ultra High Efficiency Liquid Chromatography in plasma of patients with sickle cell disease

    Darcielle Bruna Dias Elias, Teresa Maria de Jesus Ponte Carvalho, Janete Eliza de Sá Soares e mais 1Brazilian Journal of Pharmaceutical Sciences2014

    Sickle cell anemia (SCA) is a recessively inherited disease characterized by chronic hemolytic anemia, chronic inflammation, and acute episodes of hemolysis. Hydroxyurea (HU) is widely used to increase the levels of fetal hemoglobin (HbF). The objective of this study was to standardize and validate a method for the…

  6. A Reliable HPLC-UV Method for the Simultaneous Determination of Three Antiretroviral Drugs in Human Blood Plasma Applied to Therapeutic Drug Monitoring

    David R. Jaspe Lentino, Eder J. Lara Mercado, Indira B. Pájaro Bolívar e mais 3Journal of the Brazilian Chemical Society2025

    Acquired immunodeficiency syndrome is an infectious disease caused by human immunodeficiency virus (HIV). Pharmacological antiretroviral therapy, along with therapeutic monitoring of drug plasma concentrations, facilitates adequate and effective follow-up in each patient. Our main objective was to develop and validate…

  7. Validation of an ultra-high performance liquid chromatography/UV method to quantify busulfan in plasma: application to therapeutic drug monitoring

    Laura Ben Olivo, Gabriel Giron Corrêa, Bruna Bernar Dias e mais 6einstein (São Paulo)2025

    ABSTRACT Objective This study aimed to validate a sensitive, accurate, and precise bioanalytical ultra-high-performance liquid chromatography coupled with ultraviolet (UHPLC/UV) method for the determination of busulfan in human plasma using 1,6-bis-(methanesulfonyloxy) hexane as an internal standard for therapeutic…

  8. A Retrospective of Global Navigation Satellite System Ionospheric Irregularities Monitoring Networks in Brazil

    Eurico Rodrigues de Paula, João Francisco Galera Monico, Ítalo Hirokazu Tsuchiya e mais 5Journal of Aerospace Technology and Management2023citado por 1 artigo

    ABSTRACT The use of Global Navigation Satellite System (GNSS) for air and terrestrial navigation and for many applications is increasing in the last decades. However, the Earth’s ionosphere causes GNSS signal delay due to the total electron content (TEC) and scintillation in the signal phase and amplitude. This…

  9. Effects of staff education and standardizing dosing and collection times on vancomycin trough appropriateness in ward patients

    Drayton A. Hammond, Lexis N. Atkinson, Taylor B. James e mais 2Pharmacy Practice (Granada)2017

    Abstract Background: Many institutions have guidelines for initiation and monitoring, but not timing, of vancomycin. Objective: Our objective was to evaluate vancomycin trough collection appropriateness before and after an initiative to change the dosing and trough collection times in ward patients. Methods: A…

  10. Ultra-trace monitoring of copper in environmental and biological samples by inductively coupled plasma atomic emission spectrometry after separation and preconcentration by using octadecyl silica membrane disks modified by a new schiff's base

    Mohammad Reza Ganjali, Mohammad Reza Pourjavid, Leila Haji-agha Babaei e mais 1Química Nova2004

    Ultra-trace amounts of Cu(II) were separated and preconcentrated by solid phase extraction on octadecyl-bonded silica membrane disks modified with a new Schiff,s base (Bis- (2-Hydroxyacetophenone) -2,2-dimethyl-1,3-propanediimine) (SBTD) followed by elution and inductively coupled plasma atomic emission spectrometric…

  11. In vitro Monitoring of Macro and Microelements in Multimineral Preparations across Dissolution Profiles by Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES)

    Aníbal de F. Santos Júnior, Ramon R. Sá, Laiana O. B. Silva e mais 3Journal of the Brazilian Chemical Society2017

    In this study, inductively coupled plasma optical emission spectrometry (ICP OES) was used for multi-element analysis in five multimineral preparations from a dissolution test, in accordance with the United States Pharmacopeia (USP 34 method): apparatus 1, 75 rpm and 900 mL of 0.1 mol L-1 HCl. Element releases in all…

  12. A novel method for fast enrichment and monitoring of hexavalent and trivalent chromium at the ppt level with modified silica MCM-41 and its determination by inductively coupled plasma optical emission spectrometry

    Mohammad Reza Ganjali, Leila Hajiagha Babaei, Alireza Badiei e mais 4Química Nova2006

    Chromium(III) at the ng L-1 level was extracted using partially silylated MCM-41 modified by a tetraazamacrocyclic compound (TAMC) and determined by inductively coupled plasma optical emision spectrometry (ICP OES). The extraction time and efficiency, pH and flow rate, type and minimum amount of stripping acid, and…

  13. Ultra-performance liquid chromatographic method for simultaneous quantification of HIV non-nucleoside reverse transcriptase inhibitors and protease inhibitors in human plasma

    Marina V. Antunes, Júlia Poeta, Jorge P. Ribeiro e mais 2Journal of the Brazilian Chemical Society2011citado por 1 artigo

    A fast ultra-performance liquid chromatographic with diode-array detection method has been developed and validated for the determination of six protease inhibitors (indinavir, amprenavir, saquinavir, atazanavir, lopinavir, and ritonavir) and two non-nucleoside reverse transcriptase inhibitors (efavirenz and…

  14. Ultra-performance liquid chromatographic method for measurement of voriconazole in human plasma and oral fluid

    Paula Boeira, Marina V. Antunes, Huander F. Andreolla e mais 2Journal of the Brazilian Chemical Society2012

    A simple, sensitive and selective ultra-performance liquid chromatography method for the determination of voriconazole in plasma and oral fluid was developed and validated. After a liquid-liquid extraction with methyl-tert-butyl ether, the analyte and internal standard were separated on a Hypersil Gold C18 column (2.1…

  15. Long-term assessment of systemic microcirculatory function and plasma cytokines after coronavirus disease 2019 (COVID-19)

    Letícia Sabioni, Andrea De Lorenzo, Hugo Caire Castro-Faria-Neto e mais 2Brazilian Journal of Infectious Diseases2023

    Abstract Systemic microvascular dysfunction has been shown to be present in COVID-19, and serum cytokines are known to be involved in the regulation of vascular function. We sought to evaluate systemic microvascular endothelial function, with laser doppler perfusion monitoring (LDPM), and plasma levels of cytokines…

  16. High-Throughput Laser Diode Thermal Desorption-Tandem Mass Spectrometry Method for Rapid Determination of Lamotrigine in Human Plasma

    Glauco Cézar F. F. Soares, Danillo F. M. C. Veloso, Iram M. Mundim e mais 3Journal of the Brazilian Chemical Society2025

    We present the development and validation of a laser diode thermal desorption coupled with mass spectrometry (LDTD-MS/MS) as a high-throughput method for bioanalysis. This technique was applied clinically to determine the pharmacokinetics (PK) of the anticonvulsant drug lamotrigine (LAM) after administering two…

  17. Influence of the clinical profile of patients with refractory epilepsy on lamotrigine plasma concentration

    André Oliveira Baldoni, Priscila Freitas-Lima, Veriano Alexandre e mais 5Brazilian Journal of Pharmaceutical Sciences2018

    ABSTRACT The purpose of this work was to evaluate the influence of the clinical profile on lamotrigine (LTG) plasma concentrations from patients with refractory epileptic seizures. In this cross-sectional study, therapeutic monitoring of LTG, and questionnaires with 75 patients with refractory epileptic seizures of a…

  18. Stir bar-sorptive extraction, solid phase extraction and liquid-liquid extraction for levetiracetam determination in human plasma: comparing recovery rates

    Priscila Freitas-Lima, Flavia Isaura Santi Ferreira, Carlo Bertucci e mais 5Brazilian Journal of Pharmaceutical Sciences2015citado por 1 artigo

    Levetiracetam (LEV), an antiepileptic drug (AED) with favorable pharmacokinetic profile, is increasingly being used in clinical practice, although information on its metabolism and disposition are still being generated. Therefore a simple, robust and fast liquid-liquid extraction (LLE) followed by high-performance…