Clinics2008

Determining plasma morphine levels using GC-MS after solid phase extraction to monitor drug levels in the postoperative period

Veronica Santos, Karin Jannet Vera López, Luciana Moraes Santos, Mauricio Yonamine, Maria José Carvalho Carmona e Silvia Regina Cavani Jorge Santos

em inglês

cita 37 obras

resumo

OBJECTIVE: To implement a selective and sensitive analytical method to quantify morphine in small volumes of plasma by gas-liquid chromatography-mass spectrometry (GC-MS), aimed at post-operatively monitoring the drug. METHOD: A gas-liquid chromatographic method with mass detection has been developed to determine morphine concentration in plasma after solid phase extraction. Morphine-d3 was used as an internal standard. Only 0.5 mL of plasma is required for the drug solid-phase extraction in the Bond Elut-Certify®, followed by the quantification of morphine derivative by GC-MS using a linear temperature program, a capillary fused silica column, and helium as the carrier and make-up gas. The method was applied to determine morphine content in plasma samples of four patients during the postoperative period of cardiac surgery. Patient-controlled analgesia with morphine was performed by a venous catheter, and a series of venous blood samples were collected. After the oro-After the orotracheal extubation, morphine plasma levels were monitored for up to 36 hours. RESULTS: The run time was 16 minutes because morphine and the internal standard were eluted after 8.8 minutes. The GC-MS method had 0.5 -1000 ng/mL linearity range (r²=0.9995), 0.1 ng/mL limit of detection, intraday and interday precision equivalent to 1.9% and 6.8%, and 0.1% and 0.8% systematic error (intraday and interday, respectively). The analytical method showed optimal absolute (98%) and relative (100.7%) recoveries. Morphine dose requirements and plasma levels are discussed. CONCLUSION: The analytical gas-liquid chromatography-mass spectrometry method is selective and adequate for morphine measurements in plasma for applications in clinical studies.

como citar · ABNT NBR 6023

SANTOS, Veronica et al. Determining plasma morphine levels using GC-MS after solid phase extraction to monitor drug levels in the postoperative period. Clinics, 2008. Disponível em: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1807-59322008000300004. Acesso em: 27 nov. 2026.

Referências

37 obras citadas

  1. 1T Reisine e G Pasternak. Opioid analgesics and antagonists. The Pharmacological Basis of Therapeutics, 1996quem mais cita →
  2. 2FEM Benseñor e DD Cicarelli. Sedation and analgesia in intensive care. Rev Bras Anestesiol., 2003quem mais cita →
  3. 3M Momeni, M Crucitti e M De Kock. Patient-controlled analgesia in the management of postoperative pain. Drugs, 2006quem mais cita →
  4. 4B.E. Marshall e D.E. Longnecker. General anaesthetics. The Pharmacological Basis of Therapeutics, 1996quem mais cita →
  5. 5DJ Chapman, SP Joel e GW Aherne. Evaluation of a differential radioimmunoassay technique for the determination of morphine and morphine-6-glucuronide in human plasma. J Pharm Biomed Anal., 1994quem mais cita →
  6. 6JW Lee, JE Pedersen, TL Moravetz e mais 3. Sensitive and specific radioimmunoassays for opiates using commercially available materials: I: Methods for the determinations of morphine and hydromorphone. J Pharm Sci., 1991quem mais cita →
  7. 7R Caldwell e H Challenger. A capillary column gas-chromatographic method for the identification of drugs of abuse in urine samples. Ann Clin Biochem., 1989quem mais cita →
  8. 8AS Christophersen, A Biseth, B Skuterud e mais 1. Identification of opiates in urine by capillary column gas chromatography of two different derivatives. J Chromatogr., 1987quem mais cita →
  9. 9B Dahlstrom, L Paalzow e PO Edlund. Simultaneous determination of codeine and morphine in biological samples by gas chromatography with electron capture detection. Acta Pharmacol Toxicol., 1977quem mais cita →
  10. 10S Felby. Morphine: its quantitative determination in nanogram amounts in small samples of whole blood by electron-capture gas chromatography. Forensic Sci Int., 1979quem mais cita →
  11. 11JM Moore. Rapid and sensitive gas chromatographic quantitation of morphine codeine and O6-acetylmorphine in illicit heroin using an electron capture detector. 1. J Chromatogr., 1978quem mais cita →
  12. 12R Wasels, F Belleville, P Paysant e mais 2. Determination of morphine in plasma by gas chromatography using a macrobore column and thermoionic detection after Extrelut column extraction: application to follow-up morphine treatment in cancer patients. J Chromatogr., 1989quem mais cita →
  13. 13M Krogh, AS Christophersen e KE Rasmussen. Automated sample preparation by on-line dialysis and trace enrichment: Analysis of morphine, 6-monoacetylmorphine, codeine, ethylmorphine and pholcodine in plasma and whole blood by capillary gas chromatography and capillary gas chromatography-mass spectrometry. J Chromatogr., 1993quem mais cita →
  14. 14U Hofmann, S Seefried, E Schweizer e mais 3. Highly sensitive gas chromatographic-tandem mass spectrometric method for the determination of morphine and codeine in serum and urine in the femtomolar range. J Chromatogr B Biomed Sci Appl, 1999quem mais cita →
  15. 15HJ Leis, G Fauler, G Raspotnig e mais 1. Quantitative analysis of morphine in human plasma by gas chromatography-negative ion chemical ionization mass spectrometry. J Chromatogr B Biomed Sci Appl, 2000quem mais cita →
  16. 16EJ Cone, WD Darwin e WF Buchwald. Assay for codeine, morphine and ten potential urinary metabolites by gas chromatography: mass fragmentography. J Chromatogr., 1983quem mais cita →
  17. 17BE Dahlstrom e LK Paalzow. Pharmacokinetics of morphine in plasma and discrete areas of the rat brain. J Pharmacokinet Biopharm., 1975quem mais cita →
  18. 18B Fryirs, M Dawson e LE Mather. Highly sensitive gas chromatographic-mass spectrometric method for morphine determination in plasma that is suitable for pharmacokinetic studies. J Chromatogr B Biomed Sci Appl., 1997quem mais cita →
  19. 19BA Goldberger, WD Darwin, TM Grant e mais 3. Measurement of heroin and its metabolites by isotope-dilution electron-impact mass spectrometry. Clin Chem., 1993quem mais cita →
  20. 20J Schuberth e J Schuberth. Gas chromatographic-mass spectrometric determination of morphine, codeine and 6-monoacetylmorphine in blood extracted by solid phase. J Chromatogr., 1989quem mais cita →
1–20 de 37 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda