acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Parameters calibration”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Mixed effect models for predicting breast height diameter from stump diameter of Oriental beech in Göldağ

    Ilker Ercanli, Alkan Gunlu e Emin Zeki BaşkentScientia Agricola2015citado por 1 artigo

    Diameter at breast height (DBH) is the simplest, most common and most important tree dimension in forest inventory and is closely correlated with wood volume, height and biomass. In this study, a number of linear and nonlinear models predicting diameter at breast height from stump diameter were developed and evaluated…

  2. Numerical simulation of anisotropic polymeric foams

    Volnei Tita e Mauricio Francisco Caliri JúniorLatin American Journal of Solids and Structures2012citado por 1 artigo

    This paper shows in detail the modelling of anisotropic polymeric foam under compression and tension loadings, including discussions on isotropic material models and the entire procedure to calibrate the parameters involved. First, specimens of poly(vinyl chloride) (PVC) foam were investigated through experimental…

  3. Parameters for Validating a Spectrometric System with Itinerant NaI(Tl) in the Activimeter Calibration

    D.A. Conceição, J.U. Delgado e O.L. Trindade FilhoBrazilian Journal of Radiation Sciences2025

    Abstract In radiopharmaceutical production centers and nuclear medicine services, short half-life radionuclides are essential. They have been used as radiotracers since their use increased significantly and aroused the interest of national metrology laboratories, which are responsible for providing traceability to…

  4. Antarctic biological soil crusts surface reflectance patterns from landsat and sentinel-2 images

    ELIANA L. FONSECA, EDVAN C. DOS SANTOS, ANDERSON R. DE FIGUEIREDO e mais 1Anais da Academia Brasileira de Ciências2022

    Abstract The remote sensing techniques must be used to obtain long-term information in remote areas, like the Antarctic continent, to monitor the environmental productivity and its changes. The aim of this work was to analyze the surface reflectance profile patterns for the Antarctic biological soil crusts (algae…

  5. Calibration of simulation parameters for wind erosion gas-solid two-phase flow in arid and semiarid soils

    Baoer Hao, Xin Tong, Zhi Chen e mais 1Revista Brasileira de Engenharia Agrícola e Ambiental2022citado por 1 artigo

    ABSTRACT To construct a coupled simulation model of soil wind erosion and two-phase flow in arid and semiarid regions, the proper contact parameters of the soil discrete element simulation model are obtained based on the angle of repose (AoR) calibration test. The coupled simulation model is established by combining…

  6. Efficient number of calibrated cross sections bottom levels on a hydrodynamic model using the SCE-UA algorithm. Case study: Madeira River

    João Paulo Lyra Fialho Brêda, Juan Martín Bravo e Rodrigo Cauduro Dias de PaivaRBRH2017citado por 1 artigo

    ABSTRACT Hydrodynamic models are important tools for simulating river water level and flow. A considerable fraction of the hydrodynamic model errors are related to parameters uncertainties. As cross sections bottom levels considerably affect water level simulation, this parameter has to be well estimated for flood…

  7. Neutron probe calibration correction by temporal stability parameters of soil water content probability distribution

    K. Reichardt, O. Portezan, O.O.S. Bacchi e mais 4Scientia Agricola1997citado por 1 artigo

    A neutron probe calibration correction is proposed in order to reduce soil water content variability, assumed to be a consequence of improper calibrations relations. The time stability of spatially measured soil water content data is used to correct the intercepts of linear calibration relations. This procedure…

  8. Calibration of Concrete Damaged Plasticity Model parameters for shear walls

    Leonardo Martins e Silva, André Luis Christoforo e Roberto Chust CarvalhoMatéria (Rio de Janeiro)2021citado por 2 artigos

    ABSTRACT Reinforced concrete structures are relatively complex to analyze, with nonlinear effects like cracking, crushing, steel yielding, aggregate interlock, dowel effect, concrete-rebar interaction and so on. The concrete damaged plasticity CDP model is a consolidated smeared-crack model which accounts for…

  9. CALIBRATION AND OPTIMIZATION OF DISCRETE ELEMENT PARAMETERS FOR COATED COTTON SEEDS

    Zenglu Shi, Meijing Wang, Xuejun Zhang e mais 2Engenharia Agrícola2024

    ABSTRACT The geometric characteristics, physical parameters and contact parameters of coated cotton seeds were obtained through theoretical analysis and experimental measurements. A discrete element model reflecting the intrinsic parameters of cotton seeds was established, the contact parameters of coated cotton seeds…

  10. Modeling, optimizing and simulating robot calibration with accuracy improvement

    José Maurício S. T. Motta e R. S. McmasterJournal of the Brazilian Society of Mechanical Sciences1999citado por 1 artigo

    This work describes techniques for modeling, optimizing and simulating calibration processes of robots using off-line programming. The identification of geometric parameters of the nominal kinematic model is optimized using techniques of numerical optimization of the mathematical model. The simulation of the actual…

  11. AVANÇOS ANALÍTICOS BASEADOS EM MODELOS DE CALIBRAÇÃO DE PRIMEIRA ORDEM E ESPECTROSCOPIA UV-VIS PARA AVALIAÇÃO DA QUALIDADE DA ÁGUA: UMA REVISÃO - PARTE 1

    Grazielle R. Santos, Gabriela S. P. Paulino, Grazielle P. I. Borges e mais 2Química Nova2022

    This work aimed to infer about the scientific progress of the use of ultraviolet-visible (UV-Vis) spectrophotometry for evaluations of water quality. The research started in the 60s, when the imminence of obtaining characteristics of the UV-Vis spectrum that estimated the water quality. From a temporal perspective…

  12. Validation of multivariate calibration models in the determination of sugar cane quality parameters by near infrared spectroscopy

    Patrícia Valderrama, Jez W. B. Braga e Ronei J. PoppiJournal of the Brazilian Chemical Society2007citado por 3 artigos

    The determination of soluble solids (BRIX), polarizable sugars (POL) and reducing sugars (RS) sugar cane juice by using near infrared spectroscopy (NIR) and multivariate calibration was developed and validated by calculation of figures of merit. Due to the heterogeneity of the samples, first it was necessary to…

  13. Calibration of TLM Model for Semiconductor Optical Amplifier by Heuristic Parameters' Extraction

    P. Rocha, C. M. Gallep, T. Sutili e mais 1Journal of Microwaves, Optoelectronics and Electromagnetic Applications2018citado por 3 artigos

    Abstract The systemic behavior of a Semiconductor Optical Amplifier model was optimized through extensive simulations, reaching reasonable approximation to experimental obtained from commercial devices for the optical gain versus bias current, for different optical inputs powers (-25 up to 0 dBm), and for the gain…

  14. Sensitivity analysis of the AquaCrop parameters for rainfed corn in the South of Brazil

    Luiz Carlos Pittol MartiniPesquisa Agropecuária Brasileira2018

    Abstract: The objective of this work was to perform a sensitivity analysis of the main input parameters required for the AquaCrop water balance model, using biomass and grain yield data of a rainfed-simulated corn crop, obtained along the climate data series of 1987-2016 in the South of Brazil. The levels of…

  15. Corrections to prediction of backfat thickness and relationships among model parameters in INRAPORC®

    Sebastião Ferreira Magagnin, Lucélia Hauptli e Marson Bruck WarpechowskiRevista Brasileira de Zootecnia2020

    ABSTRACT We evaluated whether the procedure for correcting backfat thickness (BT) equation coefficients and lipid mass (LM) initial values in animal profiles, as well as actual model parameter (MP) data and their interrelationships, could reduce errors in predicting body weight (BW) and BT in pigs reared in Southern…

  16. THE USE OF FUZZY RULE-BASED SYSTEMS IN DETERMINING HORIZONTAL PCO PARAMETERS OF GNSS ANTENNAS

    Nassau de Nogueira Nardez, Cláudia Pereira Krueger, Rosana Sueli da Motta Jafelice e mais 1Boletim de Ciências Geodésicas2018

    Abstract Knowledge concerning Phase Center Offset (PCO) is an important aspect in the calibration of GNSS antennas and has a direct influence on the quality of high precision positioning. Studies show that there is a correlation between meteorological variables when determining the north (N), east (E) and vertical Up…

  17. Prediction of parameters (soluble solid and pH) in intact plum using NIR spectroscopy and wavelength selection

    Rosangela C. Costa e Kássio M. G. de LimaJournal of the Brazilian Chemical Society2013

    The aim of this study was to evaluate the potential of near-infrared reflectance spectroscopy (NIRS) as a rapid and nondestructive method to determine the soluble solid content (SSC) and pH of intact plums. Samples of plum with total solid contents ranging from 5.7 to 15% and pH from 2.72 to 3.84 were collected from…

  18. Rapid non-invasive assessment of quality parameters in ground soybean using near-infrared spectroscopy

    Larissa Rocha dos Santos, Marcela de Souza Zangirolami, Núbia Oliveira Silva e mais 2Pesquisa Agropecuária Brasileira2018

    Abstract: The objective of this work was to evaluate multivariate calibration models to predict total lipids, crude protein, and moisture content in grinded soybean grains using near-infrared spectroscopy and partial least squares (PLS). Three hundred samples of grinded soybean, evaluated in duplicate, were used for…