Brazilian Journal of Radiation Sciences2025

Parameters for Validating a Spectrometric System with Itinerant NaI(Tl) in the Activimeter Calibration

D.A. Conceição, J.U. Delgado e O.L. Trindade Filho

em inglês

cita 11 obras

resumo

Abstract In radiopharmaceutical production centers and nuclear medicine services, short half-life radionuclides are essential. They have been used as radiotracers since their use increased significantly and aroused the interest of national metrology laboratories, which are responsible for providing traceability to radioactive standards. Therefore, knowledgement of the activity of administered radiopharmaceuticals must be obtained accurately. However, their short half-lives prevent the provision of traceability. To overcome these obstacles, an itinerant system based on a NaI(Tl)-type scintillator detector is being developed at the National Laboratory for Ionizing Radiation Metrology (LNMRI). This work aims to show the schematic arrangement of the system developed to calibrate activimeters, as well as the tests and experimental comparisons carried out in this study using performance indicator parameters to characterize and validate the itinerant NaI(Tl) detection system in the calibration of activimeters.

como citar · ABNT NBR 6023

CONCEIÇÃO, D.A.; DELGADO, J.U.; TRINDADE FILHO, O.L. Parameters for Validating a Spectrometric System with Itinerant NaI(Tl) in the Activimeter Calibration. Brazilian Journal of Radiation Sciences, 2025. DOI: 10.15392/2319-0612.2025.2810.

Referências

11 obras citadas

  1. 1IAEA. Quantitative Nuclear Medicine Imaging: Concepts, Requirements and Methods. Human Health Reports No 9, 2014quem mais cita →
  2. 2G. B. Saha. Fundamentals of Nuclear Pharmacy. 2004quem mais cita →
  3. 3C. Michotte, M. Nonis, P. Arenillas e mais 10. Activity measurements of the radionuclide 99mTc for the CNEA, Argentina and the LNMRI/IRD, Brazil in the ongoing comparison BIPM.RI(II)-K4.Tc-99m. Metrologia (Online), 2013quem mais cita →
  4. 4ISO. Measurement of radioactivity - Gamma-ray emitting radionuclides - Generic test method using gamma-ray spectrometry. ISO/20042, 2019quem mais cita →
  5. 5D. A. Azeredo, J. U. Delgado e A. E. Oliveira. Viabilidade para implantação de um sistema itinerante de referência para medição de radiofármacos no LNMRI. CBMRI, 2020quem mais cita →
  6. 6S. R. Cherry, J. A. Sorenson e M. E. Phelps. Physics in Nuclear Medicine. 2020quem mais cita →
  7. 7ISO. Requisitos gerais para a competência de laboratórios de ensaio e calibração. ISO/IEC 17025, 2017quem mais cita →
  8. 8Osprey. Universal Digital MCA Tube Base, 7066438E. User's Manual. 2012quem mais cita →
  9. 9F. L. Cacais, J. U. Delgado e V. M. Loayza. Uncertainty evaluation of a modified elimination weighing for source preparation. Brazilian Congress on Metrology, IOP Conf. Series: Journal of Physics: Conf. Series, 2017quem mais cita →
  10. 10INMETRO. Vocabulário Internacional de Metrologia: Conceitos fundamentais e gerais e termos associados (VIM 2012). 2012quem mais cita →
  11. 11ISO. Determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measurements of ionizing radiation - Fundamentals and application. ISO 11929, 2019quem mais cita →

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações