acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Mini-implants”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Mini-implants and miniplates generate sub-absolute and absolute anchorage

    Alberto ConsolaroDental Press Journal of Orthodontics2014citado por 3 artigos

    The functional demand imposed on bone promotes changes in the spatial properties of osteocytes as well as in their extensions uniformly distributed throughout the mineralized surface. Once spatial deformation is established, osteocytes create the need for structural adaptations that result in bone formation and…

  2. Biomechanics of extra-alveolar mini-implants

    Marcio R. AlmeidaDental Press Journal of Orthodontics2019citado por 2 artigos

    ABSTRACT It is undeniable that extra-alveolar mini-implants anchorage has revolutionized Orthodontics. Correspondingly, the proper understanding of mini-implants biomechanics allowed to broaden the range of dental movements as never seen before in clinical practice. However, in order to produce better treatments…

  3. Evaluation of stability of three different mini-implants, based on thread shape factor and numerical analysis of stress around mini-implants with different insertion angle, with relation to en-masse retraction force

    Safiya Sana, Rekha Reddy, Ashok Kumar Talapaneni e mais 3Dental Press Journal of Orthodontics2020

    ABSTRACT Objectives: Assess the stability of three different mini-implants, based on thread shape factor (TSF), and evaluate stresses at the mini-implant site and surrounding cortical bone on application of retraction force, at two different insertion angles. Methods: Mini-implants of three different diameters (M1 -…

  4. Why are mini-implants lost: The value of the implantation technique!

    Fabio Lourenço Romano e Alberto ConsolaroDental Press Journal of Orthodontics2015citado por 2 artigos

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant…

  5. Reasons for mini-implants failure: choosing installation site should be valued!

    Alberto Consolaro e Fábio Lourenço RomanoDental Press Journal of Orthodontics2014citado por 3 artigos

    Mini-implant loss is often associated with physical and mechanical aspects that result from choosing an inappropriate placement site. It is worth highlighting that: a) Interdental alveolar bone crests are flexible and deformable. For this reason, they may not offer the ideal absolute anchorage. The more cervical the…

  6. Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants

    Celha Borges Costa Alves, Márcio Nunes Segurado, Miriam Cristina Leandro Dorta e mais 3Dental Press Journal of Orthodontics2016citado por 1 artigo

    ABSTRACT Objective: To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Methods: Six mini-implants (Conexão(tm), Neodent(tm) and SIN(tm)) were separately immersed in artificial saliva (pH 6.76) for 30 and 60…

  7. Stress and displacement of mini-implants and appliance in Mini-implant Assisted Rapid Palatal Expansion: analysis by finite element method

    Pedro Lima Emmerich OLIVEIRA, Kayque Euclides Moreira SOARES, Rafhael Milanezi de ANDRADE e mais 4Dental Press Journal of Orthodontics2021

    ABSTRACT Objective: In this study, simulations were performed by the finite element method (FEM) to determine the tension and displacement in mini-implants and in expander appliance during rapid maxillary expansion, by varying the number and location of the mini-implants. Methods: For the computational simulation, a…

  8. Treatment of bimaxillary protrusion using intra- and extra-alveolar miniscrews associated to self-ligating brackets system

    Henrique Mascarenhas VillelaDental Press Journal of Orthodontics2020

    ABSTRACT Introduction: Moderate and severe bimaxillary protrusion impair the passive lip sealing and the facial and smile esthetics. The extraction of premolars can be avoided by the use of skeletal anchorage to retract both dental arches. This approach brings many advantages such as: prevents premolars extraction…

  9. Flexural strength of mini-implants developed for Herbst appliance skeletal anchorage: a study in Minipigs br1 cadavers

    Klaus Barretto Lopes, Gladys Cristina Dominguez, Caio Biasi e mais 1Dental Press Journal of Orthodontics2013citado por 1 artigo

    OBJECTIVE: The present study was designed to verify if mini-implant prototypes (MIP) developed for Herbst appliance anchorage are capable of withstanding orthopedic forces, and to determine whether the flexural strength of these MIP varies depending on the site of insertion (maxilla and mandible). METHODS: Thirteen…

  10. The intra- and inter-rater reproducibility of bone level measurements at strategic mini-implants using dental panoramic radiography

    Martin Strauch, Ahmad Al Jaghsi, Christian Schwahn e mais 1Clinics2024

    Abstract Objectives: This experimental study focused on the intra- and inter-rater reproducibility of vertical bone level (VBL) measurements at strategic mini-implants (MI) using digital panoramic radiographs (PR). Study design: VBLs of 152 MIs for removable partial denture stabilization at 50 randomly chosen PRs from…

  11. Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study

    Danielle GESHAY, Phillip CAMPBELL, Larry TADLOCK e mais 3Dental Press Journal of Orthodontics2021

    ABSTRACT Introduction: Shorter miniscrew implants (MSIs) are needed to make orthodontics more effective and efficient. Objective: To evaluate the stability, insertion torque, removal torque and pain associated with 3 mm long MSIs placed in humans by a novice clinician. Methods: 82 MSIs were placed in the buccal…

  12. Survival rate and stability of surface-treated and non-surface-treated orthodontic mini-implants: a randomized clinical trial

    Janani RAVI, Sangeetha DURAISAMY, Krishnaraj RAJARAM e mais 2Dental Press Journal of Orthodontics2023

    ABSTRACT Objectives: This clinical trial was conducted to evaluate the stability and failure rate of surface-treated orthodontic mini-implants and determine whether they differ from those of non-surface-treated orthodontic mini-implants. Trial Design: Randomized clinical trial with a split-mouth study design. Setting…

  13. Fracture strength of orthodontic mini-implants

    Tatiana Feres Assad-Loss, Flávia Mitiko Fernandes Kitahara-Céia, Giordani Santos Silveira e mais 2Dental Press Journal of Orthodontics2017citado por 1 artigo

    ABSTRACT Objective: This study aimed at evaluating the design and dimensions of five different brands of orthodontic mini-implants, as well as their influence on torsional fracture strength. Methods: Fifty mini-implants were divided into five groups corresponding to different manufactures (DEN, RMO, CON, NEO, SIN)…

  14. Overall treatment outcome achieved during distal movement of the entire maxillary dentition using mini-implants - A single-center analytical observational clinical study

    A. Sumathi Felicita e Lirin Ann ThomasRevista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial2022citado por 1 artigo

    Abstract Objectives: To evaluate the overall treatment outcome and undesirable side effects during distal movement of the entire maxillary dentition using mini-implants. Methods: Seventeen patients older than fifteen years with a mild-to-moderate arch length/tooth size discrepancy were selected. Leveling and aligning…

  15. Corrosion effects related to bending fracture resistance of orthodontic mini-implants

    Alef da Silva, Felipe Gomes Dallepiane, Letícia Copatti Dogenski e mais 7Brazilian Journal of Oral Sciences2025

    Aim this study is to evaluate the effect of corrosion on flexural fracture resistance in orthodontic mini-implants composed of two materials and submerged in salivary substitutes with or without fluoride. Methods twenty mini-implants were used, 10 from SIN Company (Ti6AL4V alloys) and 10 from Morelli (steel alloys)…

  16. Prevalence of orthodontically induced inflammatory root resorption (OIIRR) associated with distal movement of the maxillary teeth with mini-implants - A preliminary CBCT cohort study

    A. Sumathi Felicita e T.N. Uma MaheswariRevista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial2025

    Abstract Objectives: To investigate the prevalence of orthodontically induced inflammatory root resorption (OIIRR) during distal movement of the entire maxillary dentition with mini-implants using cone-beam computed tomography. Methods: A total of 224 teeth from 16 patients were evaluated. Distal movement of the…

  17. Comparative evaluation of orthodontic mini-implants hygiene protocols on subgingival bacterial load

    Amanda Osório Ayres de FREITAS, Ana Paula Vieira COLOMBO, Celuta Sales ALVIANO e mais 5Dental Press Journal of Orthodontics2025

    ABSTRACT Objective: The aim of this study was to evaluate the effectiveness of four hygiene protocols for orthodontic mini-implants in reducing the subgingival bacterial load in the peri-implant sulcus. Methods: Thirty-nine healthy individuals who had fifty-nine as-received mini-implants (20 men, 19 women, 20 to 42…

  18. Insertion torque, flexural strength and surface alterations of stainless steel and titanium alloy orthodontic mini-implants: an in vitro study

    Gustavo Lopes PULS, Guido Artemio MARAÑÓN-VÁSQUEZ, Christian Andrew Vargas RAMOS e mais 5Dental Press Journal of Orthodontics2024

    ABSTRACT Objective: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. Methods: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks…

  19. MARPE expander activation load with different configurations of extender arms heights: in-vitro evaluation

    Staell Ribeiro de FARIA, Túlio Rodrigues de ANDRADE, Cristiane Barros ANDRÉ e mais 3Dental Press Journal of Orthodontics2024

    ABSTRACT Objective: Evaluate the load mini-implants exert on the artificial bone when expanding the MARPE EX in three different extension arm configurations. Methods: A device simulating the human palate was fabricated and attached to a universal testing machine, for conducting tests with different MARPE expanders…