Dental Press Journal of Orthodontics2014

Reasons for mini-implants failure: choosing installation site should be valued!

Alberto Consolaro e Fábio Lourenço Romano

em inglês

citado por 3 artigoscita 12 obras, 2 no acervo

resumo

Mini-implant loss is often associated with physical and mechanical aspects that result from choosing an inappropriate placement site. It is worth highlighting that: a) Interdental alveolar bone crests are flexible and deformable. For this reason, they may not offer the ideal absolute anchorage. The more cervical the structures, the more delicate they are, thus offering less physical support for mini-implant placement; b) Alveolar bone crests of triangular shape are more deformable, whereas those of rectangular shape are more flexible; c) The bases of the alveolar processes of the maxilla and the mandible are not flexible, for this reason, they are more likely to receive mini-implants; d) The more cervical a mini-implant is placed, the higher the risk of loss; the more apical a mini-implant is placed, the better its prognosis will be; e) 3D evaluations play a major role in planning the use of mini-implants. Based on the aforementioned considerations, the hypotheses about mini-implant loss are as follows: 1) Deflection of maxillary and mandibular alveolar processes when mini-implants are more cervically placed; 2) Mini-implants placed too near the periodontal ligament, with normal intra-alveolar tooth movement; 3) Low bone density, low thickness and low alveolar bone volume; 4) Low alveolar cortical bone thickness; 5) Excessive pressure inducing trabecular bone microfracture; 6) Sites of higher anatomical weakness in the mandible and the maxilla; 7) Thicker gingival tissue not considered when choosing the mini-implant.

como citar · ABNT NBR 6023

CONSOLARO, Alberto; ROMANO, Fábio Lourenço. Reasons for mini-implants failure: choosing installation site should be valued! Dental Press Journal of Orthodontics, 2014. DOI: 10.1590/2176-9451.19.2.018-024.OIN.

Referências

12 obras citadas · 2 no acervo

  1. 1MCD Andruciolli. Mini-implantes ortodônticos: avaliação microbiológica e quantificação de endotoxicina bacteriana, citocinas pró-inflamatórias e marcadores da osteoclastogênese. 2013quem mais cita →
  2. 2TM Araújo, MHA Nascimento, F Bezerra e mais 1. Ancoragem esquelética em Ortodontia com miniimplantes. Rev Dental Press Ortod Ortop Facial, 2006no acervo →
  3. 3Y Chen, HM Kyung, WT Zhao e mais 1. Critical factors for the sucess or orthodontic mini-implants: a systematic review. Am J Orthod Dentofacial Orthop, 2009quem mais cita →
  4. 4AO Freitas, CS Alviano, DS Alviano e mais 3. Microbial colonization in orthodontic mini-implants. Braz Dent J, 2012no acervo →
  5. 5S Miyawaki, I Koyama, M Inoue e mais 3. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop, 2003quem mais cita →
  6. 6HM Kyung, HS Park, SM Bae e mais 2. Development of orthodontic micro-implants for intraoral anchorage. J Clin Orthod, 2003quem mais cita →
  7. 7RA Reynders, L Ronchi e S Bipat. Mini-implants in orthodontics: a systematic review of the literature. Am J Orthod Dentofacial Orthop, 2009quem mais cita →
  8. 8RA Reynders, L Ronchi, L Ladu e mais 2. Insertion torque and success of orthodontic mini-implants: a systematic review. Am J Orthod Dentofacial Orthop, 2012quem mais cita →
  9. 9J Sugawara e M Nishimura. Minibone plates: the skeletal anchorage system. Semin Orthod, 2005quem mais cita →
  10. 10T Takaki, N Tamura, M Yamamoto e mais 3. Clinical study of temporary anchorage devices for orthodontic treatment-stability of micro/mini-screws and mini-plates: experience with 455 cases. Bull Tokyo Dent Coll, 2010quem mais cita →
  11. 11B Vande Vannet, MM Sabzevar, H Wehrbein e mais 1. Osseointegration of miniscrews: a histomorphometric evaluation. Eur J Orthod, 2007quem mais cita →
  12. 12D Wiechmann, U Meyer e A Buchter. Success rate mini- and micro-implants used for orthodontic Anchorage: a prospective clinical study. Clin Oral Implants Res, 2007quem mais cita →

Quem cita esta obra

3 artigos do acervo

ano a anomais citada em 2015 · 1 artigo
Mais citada em 2015, com 1 artigo.
  • 2015: citada em 1 artigo
  • 2019: citada em 1 artigo
  • 2021: citada em 1 artigo

quem fala desta obra

12 pessoas
ver as 12 pessoas e os artigos →

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações