acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Eye, artificial”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Artificial eye amplitudes and characteristics in enucleated socket with porous polyethylene spherical and quad-motility implant

    Lucia Miriam Dumont Lucci, Ana Luisa Höfling-Lima, Clélia Maria Erwenne e mais 1Arquivos Brasileiros de Oftalmologia2007

    PURPOSE: To compare artificial eye amplitudes in enucleated socket with porous polyethylene either spherical or quad-motility implant and study the characteristics of artificial eyes fit with the two orbital implants. METHODS: A total of 21 patients were prospectively studied who underwent enucleation because of an…

  2. Use of a gel biopolymer for the treatment of eviscerated eyes: experimental model in rabbits

    Francisco de Assis Cordeiro-Barbosa, José Lamartine de Andrade Aguiar, Mariana Montenegro de Melo Lira e mais 2Arquivos Brasileiros de Oftalmologia2012citado por 6 artigos

    PURPOSE: To evaluate histologically the integration process of cellulose gel produced by Zoogloea sp when implanted into rabbits' eviscerated eyes. METHODS: This experimental study employed 36 eyes of 18 rabbits subjected to evisceration of their right eyes. The sclerocorneal bag was sutured and filled with biopolymer…

  3. Assessment of the flexural strength of two heat-curing acrylic resins for artificial eyes

    Aline Úrsula Rocha Fernandes, Aline Portugal, Letícia Rocha Veloso e mais 2Brazilian Oral Research2009citado por 1 artigo

    Prosthetic eyes are artificial substitutes for the eyeball, made of heat-curing acrylic resin, serving to improve the esthetic appearance of the mutilated patient and his/her inclusion in society. The aim of this study was to assess the flexural strength of two heat-curing acrylic resins used for manufacturing…

  4. Color alteration of the paint used for iris painting in ocular prostheses

    Aline Úrsula Rocha Fernandes, Marcelo Coelho Goiato, Marcos Antônio Jacó Batista e mais 1Brazilian Oral Research2009citado por 3 artigos

    The purpose of this study was to assess color alteration of the paints used for iris painting in artificial eyes. Five disks of heat cured acrylic resin were confectioned by microwave energy for each paint analyzed, in a total of 40 specimens. Each specimen consisted of a colorless acrylic resin disk and another of…

  5. Evaluation of ocular prosthesis biofilm and anophthalmic cavity contamination after use of three cleansing solutions

    Regina Márcia Zuccolotto Felippe Paranhos, Carlos Henrique Batalhão, Marisa Semprini e mais 3Journal of Applied Oral Science2007citado por 4 artigos

    In addition to an initial socket discomfort, ocular prosthesis (OP) installation may allow the adherence of fungi and/or bacteria due to the superficial characteristics of the prosthesis' material, use of inadequate cleansing solutions and methods, or because the void located between the internal portion of the…

  6. Spontaneous extrusion of a Müller sphere 30 years after evisceration

    Camyla Lemos Budib, Jade Pinto de Queiroz Guerra, Bernardo Kaplan Moscovici e mais 3Revista Brasileira de Oftalmologia2026

    ABSTRACT We report a rare case of spontaneous extrusion of a Müller sphere implant three decades after ocular evisceration. A 44-year-old woman, with a history of evisceration of the left eye due to phthisis bulbi from congenital syphilis, presented with extrusion of an orbital implant. Surgical management consisted…

  7. The influence of whole-body vibration, media, and artificial lighting on eye-movement during reading

    Valéria Prata Lopes, Maria Lúcia Machado Duarte, Lázaro Valentim Donadon e mais 3Revista Brasileira de Oftalmologia2023

    ABSTRACT Objective: To evaluate if participants, subjected to whole-body vibration, two different types of media (paper versus tablet) and two lighting environments (fluorescent versus LED), present a difference in eye-movement parameters during reading tasks. Methods: Fourteen adults silently read two different texts…

  8. Efficacy of povidone and propylene glycol–based artificial tears in the treatment of dry eye disease

    Laura Caldas dos Santos, Alléxya Affonso, Rubens Belfort Jr. e mais 1Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: This clinical study aimed to assess the effectiveness of microemulsion artificial tears containing povidone and propylene glycol in the management of dry eye disease. Secondary objectives included evaluating improvements in tear-film stability, measured by tear break-up time and corneal staining…

  9. Comparison of the refractive prediction errors of artificial intelligence formula with 3 conventional formulas and 11 combination methods in cataract surgery on eyes with short axial length

    Song-A Che, Mincheol Seong, Kookyoung Kim e mais 1Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: To compare the refractive prediction error of Hill-radial basis function 3.0 with those of 3 conventional formulas and 11 combination methods in eyes with short axial lengths. Methods: The refractive prediction error was calculated using 4 formulas (Hoffer Q, SRK-T, Haigis, and Hill-RBF) and 11…

  10. Evaluation of the color stability of two techniquesfor reproducing artificial irides after microwave polymerization

    Marcelo Coelho Goiato, Daniela Micheline dos Santos, Amália Moreno e mais 2Journal of Applied Oral Science2011

    The use of ocular prostheses for ophthalmic patients aims to rebuild facial aesthetics and provide an artificial substitute to the visual organ. Natural intemperate conditions promote discoloration of artificial irides and many studies have attempted to produce irides with greater chromatic paint durability using…

  11. Simulated phacoemulsification training using the OrbiTau artificial eye: Experience at a single institute

    Tauanni Cândido, Roberto Pineda, Silvana Rossi e mais 2Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: The OrbiTau surgical simulator is a synthetic eye model developed to enhance cataract surgical training. Herein, we aimed to describe the perspectives of Harvard’s Ophthalmology faculty and residents regarding the effectiveness of OrbiTau. Methods: A cross-sectional study was conducted in which 11…

  12. Trends in the management of anophthalmic sockets and external ocular prostheses among oculoplastic surgeons: a web-based study

    Alicia Galindo-Ferreiro, Elvira Martinez-Fernandez, Carolina Pereira Bigheti e mais 3Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: This study aimed to evaluate the practices employed by oculoplastic surgeons in the assessment and management of anophthalmic sockets and external ocular prostheses. Methods: Oculoplastic surgeons from two countries, who specialized in the management of anophthalmic sockets, participated in a…

  13. Capsular bag folding associated with in-the-bag intraocular lens displacement in pseudoexfoliation syndrome

    Ángela Martínez Sobrino, María Luna del Castillo e Herman Casado BlancoRevista Brasileira de Oftalmologia2025

    We present the case of an 80-year-old patient diagnosed with severe pseudoexfoliation syndrome (PEX) in both eyes (OU), who underwent uneventful bilateral phacoemulsification with in-the-bag intraocular lens (IOL) implantation 10 years ago. However, 4 years postoperatively, the patient developed subluxation of the…

  14. Chromatic stability of acrylic resins of artificial eyes submitted to accelerated aging and polishing

    Marcelo Coelho Goiato, Daniela Micheline dos Santos, Josiene Firmino Souza e mais 2Journal of Applied Oral Science2010

    Esthetics and durability of materials used to fabricate artificial eyes has been an important issue since artificial eyes are essential to restore esthetics and function, protect the remaining tissues and help with patients' psychological therapy. However, these materials are submitted to degrading effects of…

  15. Evaluation of the etiology of ocular globe atrophy or loss

    Viviane Regina Côas, Ana Christina Claro Neves e Sigmar de Mello RodeBrazilian Dental Journal2005citado por 1 artigo

    This survey investigated the etiology of atrophy or loss of the ocular globe in patients assisted at the Maxillofacial Prosthetics Clinic of two Schools of Dentistry in São Paulo State, Brazil. A total of 238 patients were examined and their clinical files were reviewed. The etiology of eyeball atrophy/loss was…

  16. Effects of the preoperative use of artificial tears combined with recombinant bovine basic fibroblast growth factor on cataract patients complicated with dry eyes

    Wei Xiao e Pengcheng HuangArquivos Brasileiros de Oftalmologia2024

    ABSTRACT Purpose: To assess the effects of the preoperative application of artificial tears combined with recombinant bovine basic fibroblast growth factor on the ocular surface function and inflammatory factor levels after operation in cataract patients complicated with dry eyes. Methods: A total of 118 cataract…

  17. 20% Autologous serum vs. 0.05% cyclosporine and preservative-free artificial tears in the treatment of Sjögren related dry eye

    Mustafa Berhuni, Şeref İstek e Nesime Setge TıskaoğluArquivos Brasileiros de Oftalmologia2024

    ABSTRACT Purpose: To compare the 3-month results of treatment with 20% autologous serum or combination treatment with preservative-free artificial tears and 0.05% cyclosporine in patients with dry eye disease due to primary Sjögren’s syndrome. Methods: A total of 130 eyes of 65 patients with newly diagnosed dry eye…

  18. Effectiveness of using preservative-free artificial tears versus preserved lubricants for the treatment of dry eyes: a systematic review

    Marina Viegas Moura Rezende Ribeiro, Fabiano Timbó Barbosa, Luiz Eduardo Feliciano Ribeiro e mais 2Arquivos Brasileiros de Oftalmologia2019

    ABSTRACT This systematic review aimed to assess the effectiveness of using preservative-free artificial tears versus preserved lubricants for the treatment of dry eyes in Universidade Federal de Alagoas (PROSPERO 2018 CRD42018089933). Online databases were searched (LILACS, EMBASE, MEDLINE, and CENTRAL) from inception…

  19. Combined transscleral fixation of an artificial iris prosthesis with an intraocular lens

    Uzeyır Gunenc, Taylan Ozturk, Gul Arikan e mais 1Arquivos Brasileiros de Oftalmologia2016

    ABSTRACT Post-traumatic aniridia combined with aphakia may be seen after globe injury. Aside from esthetic aspects, partial or total loss of the iris tissue may also be related to various degrees of glare and photophobia. Such patients suffer from severe visual impairment secondary to aphakia. Herein we describe a…

  20. Electrophysiological detection of visible wavelengths of artificial lights inducing take-off in adults of Rhodnius prolixus (Hemiptera: Triatominae)

    Mario Iván Ortiz, Eduwin Hincapié-Peñaloza e Jorge MolinaRevista do Instituto de Medicina Tropical de São Paulo2023

    ABSTRACT Rhodnius prolixus is the most important vector of Trypanosoma cruzi in the northern part of South America. The compound eyes in adults of R. prolixus are involved in the nocturnal flight dispersion from sylvatic environments into human dwellings. During this behavior, the artificial lights play an important…