PURPOSE: To compare artificial eye amplitudes in enucleated socket with porous polyethylene either spherical or quad-motility implant and study the characteristics of artificial eyes fit with the two orbital implants. METHODS: A total of 21 patients were prospectively studied who underwent enucleation because of an intraocular melanoma and the randomization defined a porous polyethylene either spherical or quad-motility orbital implant. Measurements of the amplitude of the artificial eye were obtained with prism and digital photos. The software Scion Image analyzed the digital photos (www.scioncorp.com) and the quantitative data were allocated to groups. The measurements (height, length, thickness) and weight of the 21 artificial eyes were analyzed. Student's t-test was performed to determine the significance of difference between groups (p 0.05 for all directions). On analyzing the digital photos, the artificial eye with spherical implant showed higher artificial eye amplitude downward (p=0.009) among patients older than 55 years old, rightward (p=0.036) and downward (p=0.008) among the 9 patients with enucleated right eye. Height and length were similar in the 21 artificial eyes but those artificial eyes fit with quad-motility orbital implants were statistically significant thicker (p<0.001) and heavier (p=0.001). CONCLUSIONS: The similar amplitude of movement of artificial eyes was observed with both spherical and quad-motility orbital implants. Artificial eyes fit with quad-motility orbital implant are significantly thicker and heavier than those fit with spherical orbital implant.
como citar · ABNT NBR 6023
LUCCI, Lucia Miriam Dumont et al. Artificial eye amplitudes and characteristics in enucleated socket with porous polyethylene spherical and quad-motility implant. Arquivos Brasileiros de Oftalmologia, 2007. DOI: 10.1590/S0004-27492007000500019.
Referências
28 obras citadas · 3 no acervo
- 1DR Jordan e SR Klapper. Surgical techniques in enucleation: the role of various types of implants and the efficacy of pegged and nonpegged approaches. Int Ophthalmol Clin, 2006quem mais cita →
- 2TAC Amaro, L Yazigi e C Erwenne. Aspectos psicológicos e qualidade de vida em pacientes com melanoma uveal durante o processo de tratamento por remoção do bulbo ocular. Arq Bras Oftalmol, 2006no acervo →
- 3NLP Botelho, M Volpini e EM Moura. Aspectos psicológicos em usuários de prótese ocular. Arq Bras Oftalmol, 2003no acervo →
- 4RL Anderson, MT Yen, LM Lucci e mais 1. The quasi-integrated porous polyethylene orbital implant. Ophthal Plast Reconstr Surg, 2002quem mais cita →
- 5JR Bilyk, PA Rubin e JW Shore. Correction of enophthalmos with porous polyethylene implants. Int Ophthalmol Clin, 1992quem mais cita →
- 6JW Karesh e SC Dresner. High-density porous polyethylene (Medpor) as a successful anophthalmic socket implant. Ophthalmology, 1994quem mais cita →
- 7PL Custer e KM Trinkaus. Volumetric determination of enucleation implant size. Am J Ophthalmol, 1999quem mais cita →
- 8PL Custer. Enucleation: past, present, and future. Ophthal Plast Reconstr Surg, 2000quem mais cita →
- 9GW Su e MT Yen. Current trends in managing the anophthalmic socket after primary enucleation and evisceration. Ophthal Plast Reconstr Surg, 2004quem mais cita →
- 10HD Remulla, PA Rubin, JW Shore e mais 4. Complications of porous spherical orbital implants. Ophthalmology, 1995quem mais cita →
- 11TP Colen, DA Paridaens, HG Lemij e mais 2. Comparison of artificial eye amplitudes with acrylic and hydroxyapatite spherical enucleation implants. Ophthalmology, 2000quem mais cita →
- 12AD Souza, EE Ruiz e AA Cruz. Palpebral fissure morphology segmentation and measurement using image processing. IEEE Eng Med Biol Mag, 2000quem mais cita →
- 13MP Mourits, MF Prummel, WM Wiersinga e mais 1. Measuring eye movements in Graves ophthalmopathy. Ophthalmology, 1994quem mais cita →
- 14AG Dean, JA Dean, D Coulombier e mais 3. Epi Info, Version 6.04a: a word processing database, and statistics program for public health on IBM-compatible microcomputers. 1996quem mais cita →
- 15EJC Soares. Importância da reconstrução anatômica e funcional da cavidade anoftálmica na prevenção e tratamento do processo de retração dos fórnices conjuntivaisquem mais cita →
- 16PA Rubin, J Popham, S Rumelt e mais 3. Enhancement of the cosmetic and functional outcome of enucleation with conical orbital implant. Ophthalmology, 1998quem mais cita →
- 17SM Blaydon, TR Shepler, RW Neuhaus e mais 2. The porous polyethylene (Medpor) spherical orbital implant: a retrospective study of 136 cases. Ophthal Plast Reconstr Surg, 2003quem mais cita →
- 18YO Arat, DJ Shetlar e M Boniuk. Bovine pericardium versus homologous sclera as a wrapping for hydroxyapatite orbital implants. Ophthal Plast Reconstr Surg, 2003quem mais cita →
- 19SR Seiff, JS Jr Chang, MH Hurt e mais 1. Polymerase chain reaction identification of human immunodeficiency virus-1 in preserved human sclera. Am J Ophthalmol, 1994quem mais cita →
- 20LM Lucci, MC Yu e AL Höfling-Lima. Decontamination of human sclera: an in vitro study. Cornea, 1999quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda